메뉴 건너뛰기




Volumn 11, Issue 6, 1996, Pages 750-756

Survivorship analysis of cemented total hip arthroplasty acetabular components implanted with second-generation techniques

Author keywords

cemented acetabular components; total hip arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; PROSTHESIS FAILURE; PROSTHESIS FIXATION; PROSTHESIS LOOSENING; SCORING SYSTEM; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 0029816485     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80016-7     Document Type: Article
Times cited : (17)

References (25)
  • 1
    • 0023002001 scopus 로고
    • The impact of modern cement techniques on acetabular fixation in cemented total hip replacement
    • Cornell CN, Ranawat CS: The impact of modern cement techniques on acetabular fixation in cemented total hip replacement. J Arthroplasty 1:197, 1986
    • (1986) J Arthroplasty , vol.1 , pp. 197
    • Cornell, C.N.1    Ranawat, C.S.2
  • 2
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacements
    • Delee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacements. Clin Orthop 121:20, 1976
    • (1976) Clin Orthop , vol.121 , pp. 20
    • Delee, J.G.1    Charnley, J.2
  • 3
    • 0027301351 scopus 로고
    • The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up
    • Schulte KR, Callaghan JJ, Kelley SS, Johnston RC: The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. J Bone Joint Surg 75A:961, 1993
    • (1993) J Bone Joint Surg , vol.75 A , pp. 961
    • Schulte, K.R.1    Callaghan, J.J.2    Kelley, S.S.3    Johnston, R.C.4
  • 5
    • 0019984310 scopus 로고
    • Socket fixation using a metal backed acetabular component for total hip replacement
    • Harris WH, White RE: Socket fixation using a metal backed acetabular component for total hip replacement. J Bone Joint Surg 64A:745, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 745
    • Harris, W.H.1    White, R.E.2
  • 6
    • 0023473295 scopus 로고
    • Further follow-up on socket fixation using a metal backed acetabular component for total hip replacement
    • Harris WH, Penenberg BL: Further follow-up on socket fixation using a metal backed acetabular component for total hip replacement. J Bone Joint Surg 69A:1140, 1987
    • (1987) J Bone Joint Surg , vol.69 A , pp. 1140
    • Harris, W.H.1    Penenberg, B.L.2
  • 9
    • 0026480315 scopus 로고
    • Influential factors in cemented acetabular cup loosening
    • Ritter MA, Keating M, Faris PM, Brugo G: Influential factors in cemented acetabular cup loosening. J Arthroplasty 7(suppl):365, 1992
    • (1992) J Arthroplasty , vol.7 , Issue.SUPPL. , pp. 365
    • Ritter, M.A.1    Keating, M.2    Faris, P.M.3    Brugo, G.4
  • 10
    • 0027980964 scopus 로고
    • Cementless components: The good, the bad, and the ugly
    • Kennedy WR: Cementless components: the good, the bad, and the ugly. Orthopaedics 17:783, 1994
    • (1994) Orthopaedics , vol.17 , pp. 783
    • Kennedy, W.R.1
  • 11
    • 0028136271 scopus 로고
    • Cemented all-poly cups
    • Ritter MA: Cemented all-poly cups. Orthopaedics 17:785, 1994
    • (1994) Orthopaedics , vol.17 , pp. 785
    • Ritter, M.A.1
  • 12
    • 0026538671 scopus 로고
    • Total hip arthroplasly
    • Callaghan JJ: Total hip arthroplasly. Clin Orthop 276:33, 1992
    • (1992) Clin Orthop , vol.276 , pp. 33
    • Callaghan, J.J.1
  • 13
    • 0015304601 scopus 로고
    • Total hip replacement with fixation by acrylic cement: A preliminary study of 100 consecutive McKee-Farrar prosthetic replacements
    • Wilson PD Jr, Amstutz HC, Czerniecki A et al: Total hip replacement with fixation by acrylic cement: a preliminary study of 100 consecutive McKee-Farrar prosthetic replacements. J Bone Joint Surg 54A:207, 1972
    • (1972) J Bone Joint Surg , vol.54 A , pp. 207
    • Wilson Jr., P.D.1    Amstutz, H.C.2    Czerniecki, A.3
  • 14
    • 0024441094 scopus 로고
    • Evaluation of cementless acetabular component migration
    • Massin P, Schmidt FA, Engh CA: Evaluation of cementless acetabular component migration. J Arthroplasty 4:245, 1989
    • (1989) J Arthroplasty , vol.4 , pp. 245
    • Massin, P.1    Schmidt, F.A.2    Engh, C.A.3
  • 15
    • 0023908985 scopus 로고
    • The correlation between roentgenographic appearance and operative findings at the bone cement junction of the socket in Charnley low friction arthroplasties
    • Hodgkinson JP, Shelley P, Wrobleski BM: The correlation between roentgenographic appearance and operative findings at the bone cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop 228:105, 1988
    • (1988) Clin Orthop , vol.228 , pp. 105
    • Hodgkinson, J.P.1    Shelley, P.2    Wrobleski, B.M.3
  • 16
    • 0020541681 scopus 로고
    • Total hip arthroplasties in patients less than forty-five years old
    • Dorr LD, Takei GK, Conaty JP: Total hip arthroplasties in patients less than forty-five years old. J Bone Joint Surg 65A:474, 1983
    • (1983) J Bone Joint Surg , vol.65 A , pp. 474
    • Dorr, L.D.1    Takei, G.K.2    Conaty, J.P.3
  • 17
    • 0019957225 scopus 로고
    • Femoral component loosening using contemporary techniques of femoral cement fixation
    • Harris WH, McCarthy JC Jr, O'Neill DA: Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg 64A:1063, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 1063
    • Harris, W.H.1    McCarthy Jr., J.C.2    O'Neill, D.A.3
  • 18
    • 0019981269 scopus 로고
    • A ten year follow-up study of total hip replacement: With particular reference to roentgenographic loosening of the components
    • Stauffer RN: A ten year follow-up study of total hip replacement: with particular reference to roentgenographic loosening of the components. J Bone Joint Surg 64A:983, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 983
    • Stauffer, R.N.1
  • 19
    • 0026490462 scopus 로고
    • Debris from cobalt-chrome cable may cause acetabular loosening
    • Kelley SS, Johnston RC: Debris from cobalt-chrome cable may cause acetabular loosening. Clin Orthop 285:140, 1992
    • (1992) Clin Orthop , vol.285 , pp. 140
    • Kelley, S.S.1    Johnston, R.C.2
  • 20
    • 0028108743 scopus 로고
    • Results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old
    • Ballard T, Callaghan JJ, Sullivan PM, Johnston RC: Results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg 76A:959, 1994
    • (1994) J Bone Joint Surg , vol.76 A , pp. 959
    • Ballard, T.1    Callaghan, J.J.2    Sullivan, P.M.3    Johnston, R.C.4
  • 21
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement: An 11-year radiographic review
    • Mulroy RD Jr, Harris WH: The effect of improved cementing techniques on component loosening in total hip replacement: an 11-year radiographic review. J Bone Joint Surg 728:757, 1990
    • (1990) J Bone Joint Surg , vol.728 , pp. 757
    • Mulroy Jr., R.D.1    Harris, W.H.2
  • 22
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B: Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72A:518, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 518
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 23
    • 0028567382 scopus 로고
    • A prospective study of a titanium femoral component for cemented total hip arthroplasty
    • Tompkins G, Lachiewicz PF: A prospective study of a titanium femoral component for cemented total hip arthroplasty. J Arthroplasty 9:623, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 623
    • Tompkins, G.1    Lachiewicz, P.F.2
  • 24
    • 85030268236 scopus 로고    scopus 로고
    • Porous-coated acetabular components with screw fixation: Five to ten year results
    • in press
    • Latimer H, Lachiewicz PP: Porous-coated acetabular components with screw fixation: five to ten year results. J Bone Joint Surg, in press
    • J Bone Joint Surg
    • Latimer, H.1    Lachiewicz, P.P.2
  • 25
    • 0026442786 scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation
    • Schmalzreid TP, Harris WH: The Harris-Galante porous-coated acetabular component with screw fixation. J Bone Joint Surg 74A:1130, 1992
    • (1992) J Bone Joint Surg , vol.74 A , pp. 1130
    • Schmalzreid, T.P.1    Harris, W.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.