메뉴 건너뛰기




Volumn 11, Issue 6, 1996, Pages 743-749

Use of bone compaction in total knee arthroplasty

Author keywords

bone compaction; reaming; tibial component stability; total knee arthroplasty

Indexed keywords

ARTICLE; BIOMECHANICS; PROSTHESIS MATERIAL; TOTAL KNEE REPLACEMENT;

EID: 0029816484     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80015-5     Document Type: Article
Times cited : (26)

References (20)
  • 1
    • 0015648310 scopus 로고
    • The effect of movement on the bonding of porous metal to bone
    • Cameron HU, Pilliar RM, MacNab I: The effect of movement on the bonding of porous metal to bone. J Biomed Mater Res 7:301, 1973
    • (1973) J Biomed Mater Res , vol.7 , pp. 301
    • Cameron, H.U.1    Pilliar, R.M.2    MacNab, I.3
  • 2
    • 0017557166 scopus 로고
    • Influence of functional dynamic loading on bone ingrowth into surface pores of orthopaedic implants
    • Ducheyne P, DeMeester P Aernoudt E et al: Influence of functional dynamic loading on bone ingrowth into surface pores of orthopaedic implants. J Biomed Mater Res 11:811, 1977
    • (1977) J Biomed Mater Res , vol.11 , pp. 811
    • Ducheyne, P.1    DeMeester, P.2    Aernoudt, E.3
  • 3
    • 0017871673 scopus 로고
    • Failure of total knee arthroplasty due to loosening and deformation of the tibial component
    • Ducheyne P, Kagan A, Lacey JA: Failure of total knee arthroplasty due to loosening and deformation of the tibial component. J Bone Joint Surg 60A:384, 1978
    • (1978) J Bone Joint Surg , vol.60 A , pp. 384
    • Ducheyne, P.1    Kagan, A.2    Lacey, J.A.3
  • 4
    • 0023765461 scopus 로고
    • Clinical aspects of osseointegration in joint replacement
    • Linder L, Carlsson A, Marsal L et al: Clinical aspects of osseointegration in joint replacement. J Bone Joint Surg 70B:550, 1988
    • (1988) J Bone Joint Surg , vol.70 B , pp. 550
    • Linder, L.1    Carlsson, A.2    Marsal, L.3
  • 5
    • 27044445815 scopus 로고
    • Direct observation of micromotion at the implant-bone interface with cemented and non-cemented tibial components
    • Manley MT, Stulberg BN, Stem LS et al: Direct observation of micromotion at the implant-bone interface with cemented and non-cemented tibial components. Proc Orthop Res Soc, 436, 1987
    • (1987) Proc Orthop Res Soc , pp. 436
    • Manley, M.T.1    Stulberg, B.N.2    Stem, L.S.3
  • 6
    • 0025634119 scopus 로고
    • Osseointegration of titanium implants of total hip arthroplasty
    • McCutchen JW, Collier JP, Mayor MB: Osseointegration of titanium implants of total hip arthroplasty. Clin Orthop 261:114, 1990
    • (1990) Clin Orthop , vol.261 , pp. 114
    • McCutchen, J.W.1    Collier, J.P.2    Mayor, M.B.3
  • 7
    • 0023118180 scopus 로고
    • Influence of stable fixation on trabecular bone healing: A morphologic assessment in dogs
    • Uhthoff HK, Goto S, Cerckel PH: Influence of stable fixation on trabecular bone healing: a morphologic assessment in dogs. J Orthop Res 5:14, 1987
    • (1987) J Orthop Res , vol.5 , pp. 14
    • Uhthoff, H.K.1    Goto, S.2    Cerckel, P.H.3
  • 8
    • 0019433118 scopus 로고
    • Fixation of tibial components of knee prostheses
    • Walker PS, Greene D, Reilly D et al: Fixation of tibial components of knee prostheses. J Bone Joint Surg 63A:257, 1981
    • (1981) J Bone Joint Surg , vol.63 A , pp. 257
    • Walker, P.S.1    Greene, D.2    Reilly, D.3
  • 9
    • 0022508045 scopus 로고
    • The total condylar prosthesis
    • Insall JN, Kelly M: The total condylar prosthesis. Clin Orthop 205:43, 1985
    • (1985) Clin Orthop , vol.205 , pp. 43
    • Insall, J.N.1    Kelly, M.2
  • 10
    • 0025342934 scopus 로고
    • Total condylar knee replacement in patients who have rheumatoid arthritis: A ten-year follow-up study
    • Laskin RS: Total condylar knee replacement in patients who have rheumatoid arthritis: a ten-year follow-up study. J Bone Joint Surg 72A:529, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 529
    • Laskin, R.S.1
  • 11
    • 0023868757 scopus 로고
    • Survivorship analysis and results of total condylar knee arthroplasty: Eight to 11-year follow-up period
    • Ranawat CS, Boachie-Adjei O: Survivorship analysis and results of total condylar knee arthroplasty: eight to 11-year follow-up period. Clin Orthop 226:6, 1988
    • (1988) Clin Orthop , vol.226 , pp. 6
    • Ranawat, C.S.1    Boachie-Adjei, O.2
  • 12
    • 0026349986 scopus 로고
    • Survivorship analysis of TKA: Cumulative rates of survival of 9200 total knee arthroplasties
    • Rand JA, Illstrup DM: Survivorship analysis of TKA: cumulative rates of survival of 9200 total knee arthroplasties. J Bone Joint Surg 73A:397, 1991
    • (1991) J Bone Joint Surg , vol.73 A , pp. 397
    • Rand, J.A.1    Illstrup, D.M.2
  • 13
    • 0024818201 scopus 로고
    • Long-term survival analysis of the posterior cruciate condylar total knee arthroplasty
    • Ritter MA, Campbell E, Faris PM, Keating ME: Long-term survival analysis of the posterior cruciate condylar total knee arthroplasty. J Arthroplasty 4:293, 1990
    • (1990) J Arthroplasty , vol.4 , pp. 293
    • Ritter, M.A.1    Campbell, E.2    Faris, P.M.3    Keating, M.E.4
  • 15
    • 0024447575 scopus 로고
    • The total condylar prosthesis, ten-to-twelve year results with a cemented knee replacement
    • Vince KG, Insall JN, Kelly MA: The total condylar prosthesis, ten-to-twelve year results with a cemented knee replacement. J Bone Joint Surg 71B:793, 1989
    • (1989) J Bone Joint Surg , vol.71 B , pp. 793
    • Vince, K.G.1    Insall, J.N.2    Kelly, M.A.3
  • 16
    • 0021153444 scopus 로고
    • Tibial component fixation in deficient tibial bone stock
    • Brooks PJ, Walker PS, Scott RD: Tibial component fixation in deficient tibial bone stock. Clin Orthop 184:302, 1984
    • (1984) Clin Orthop , vol.184 , pp. 302
    • Brooks, P.J.1    Walker, P.S.2    Scott, R.D.3
  • 17
    • 0023750130 scopus 로고
    • The rationale of cementless revision of cemented arthroplasty failures
    • Hungerford DS, Jones LC: The rationale of cementless revision of cemented arthroplasty failures. Clin Orthop 235:12, 1988
    • (1988) Clin Orthop , vol.235 , pp. 12
    • Hungerford, D.S.1    Jones, L.C.2
  • 18
    • 27044445912 scopus 로고
    • Current concepts in orthopaedic biomaterials and implant fixation
    • Friedman RJ, Black J, Galante JO et al: Current concepts in orthopaedic biomaterials and implant fixation. J Bone Mineral Res 9:87, 1994
    • (1994) J Bone Mineral Res , vol.9 , pp. 87
    • Friedman, R.J.1    Black, J.2    Galante, J.O.3
  • 19
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante JO, Rostoker W, Lueck R, Ray RO: Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg 53A:101, 1971
    • (1971) J Bone Joint Surg , vol.53 A , pp. 101
    • Galante, J.O.1    Rostoker, W.2    Lueck, R.3    Ray, R.O.4
  • 20
    • 0023551378 scopus 로고
    • Current concepts review: Biologic fixation of porous-coated implants
    • Haddad RJ, Cook SD, Thomas KA: Current concepts review: biologic fixation of porous-coated implants. J Bone Joint Surg 69A:1459, 1987
    • (1987) J Bone Joint Surg , vol.69 A , pp. 1459
    • Haddad, R.J.1    Cook, S.D.2    Thomas, K.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.