메뉴 건너뛰기




Volumn 40, Issue 3, 1996, Pages 230-234

Small gauge gelfoam plug liver biopsy in high risk patients: Safety and diagnostic value

Author keywords

Biopsy; Core; Gelfoam; Haemorrhage; High risk; Liver

Indexed keywords

GELFOAM;

EID: 0029815753     PISSN: 00048461     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1440-1673.1996.tb00392.x     Document Type: Article
Times cited : (20)

References (16)
  • 1
    • 0027043081 scopus 로고
    • Outcome of patients hospitalized for complications after outpatient liver biopsy
    • Janes CH, Lindor KD. Outcome of patients hospitalized for complications after outpatient liver biopsy. Ann. Intern. Med. 1993; 118: 96-8.
    • (1993) Ann. Intern. Med. , vol.118 , pp. 96-98
    • Janes, C.H.1    Lindor, K.D.2
  • 2
    • 0017927812 scopus 로고
    • Liver biopsy: Complications in 1000 inpatients and outpatients
    • Perrault J, McGill DB, Ott BJ, Taylor WF. Liver biopsy: Complications in 1000 inpatients and outpatients. Gastroenterology 1978; 74: 103-6.
    • (1978) Gastroenterology , vol.74 , pp. 103-106
    • Perrault, J.1    McGill, D.B.2    Ott, B.J.3    Taylor, W.F.4
  • 3
    • 0027219876 scopus 로고
    • Practice and complications of liver biopsy: Results of a nationwide survey in Switzerland
    • Froehlich F, Lamy O, Fried M, Gonvers JJ. Practice and complications of liver biopsy: Results of a nationwide survey in Switzerland. Dig. Dis. Sci. 1993; 38: 1480-4.
    • (1993) Dig. Dis. Sci. , vol.38 , pp. 1480-1484
    • Froehlich, F.1    Lamy, O.2    Fried, M.3    Gonvers, J.J.4
  • 4
    • 0015912569 scopus 로고
    • Transjugular approach to liver biopsy and transhepatic cholangiography
    • Ràsch J, Lakin PC, Antonovic R, Dotter CT. Transjugular approach to liver biopsy and transhepatic cholangiography. N. Engl. J. Med. 1973; 289: 227-31.
    • (1973) N. Engl. J. Med. , vol.289 , pp. 227-231
    • Ràsch, J.1    Lakin, P.C.2    Antonovic, R.3    Dotter, C.T.4
  • 5
    • 0020000749 scopus 로고
    • Transvenous liver biopsy: An experience based on 1000 hepatic tissue samplings with this procedure
    • Lebrec D, Goldfarb G, DeGott C, Rueff B, Benhamou J. Transvenous liver biopsy: An experience based on 1000 hepatic tissue samplings with this procedure. Gastroenterology 1982; 83: 338-40.
    • (1982) Gastroenterology , vol.83 , pp. 338-340
    • Lebrec, D.1    Goldfarb, G.2    DeGott, C.3    Rueff, B.4    Benhamou, J.5
  • 6
    • 0024243952 scopus 로고
    • Transjugular liver biopsy: An Australian experience
    • Steadman C, league C, Harper J et al. Transjugular liver biopsy: An Australian experience. Aust. N.Z. J. Med. 1988; 18: 836-40.
    • (1988) Aust. N.Z. J. Med. , vol.18 , pp. 836-840
    • Steadman, C.1    League, C.2    Harper, J.3
  • 7
    • 0026524726 scopus 로고
    • Transjugular liver biopsy: A review of 200 biopsies
    • Corr P, Beningfield SJ, Davey N. Transjugular liver biopsy: A review of 200 biopsies. Clin. Radiol. 1992; 45: 238-9.
    • (1992) Clin. Radiol. , vol.45 , pp. 238-239
    • Corr, P.1    Beningfield, S.J.2    Davey, N.3
  • 8
    • 0027473378 scopus 로고
    • A comparison of transjugular and plugged-percutaneous liver biopsy in patient with impaired coagulation
    • Sawyer AM, McCormick, PA, Tennyson GS et al. A comparison of transjugular and plugged-percutaneous liver biopsy in patient with impaired coagulation. J. Hepatol. 1993; 17: 81-5.
    • (1993) J. Hepatol. , vol.17 , pp. 81-85
    • Sawyer, A.M.1    McCormick, P.A.2    Tennyson, G.S.3
  • 9
    • 0021210934 scopus 로고
    • Percutaneous liver biopsy with plugging of the needle track: A safe method for use in patients with impaired coagulation
    • Riley SA, Irving HC, Axon ATR, Ellis R, Lincott DJ, Losowsky MS. Percutaneous liver biopsy with plugging of the needle track: A safe method for use in patients with impaired coagulation. Lancet 1984; ii: 436.
    • (1984) Lancet , vol.2 , pp. 436
    • Riley, S.A.1    Irving, H.C.2    Axon, A.T.R.3    Ellis, R.4    Lincott, D.J.5    Losowsky, M.S.6
  • 10
    • 0024545243 scopus 로고
    • Plugged liver biopsy in patients with impaired coagulation
    • Tobin MV, Gilmore IT. Plugged liver biopsy in patients with impaired coagulation. Dig. Dis. Sci. 1989; 34: 13-15.
    • (1989) Dig. Dis. Sci. , vol.34 , pp. 13-15
    • Tobin, M.V.1    Gilmore, I.T.2
  • 11
    • 0023866193 scopus 로고
    • Sheath needle for liver biopsy in high-risk patients
    • Chuang VP, Alspaugh JP. Sheath needle for liver biopsy in high-risk patients. Radiology 1988; 166: 261-2.
    • (1988) Radiology , vol.166 , pp. 261-262
    • Chuang, V.P.1    Alspaugh, J.P.2
  • 12
    • 0026702619 scopus 로고
    • US-guided percutaneous liver biopsy with plugging of the needle track: A prospective study in 72 high-risk patients
    • Zins M, Vilgrain V, Gayno S et al. US-guided percutaneous liver biopsy with plugging of the needle track: A prospective study in 72 high-risk patients. Radiology 1992; 184: 841-3.
    • (1992) Radiology , vol.184 , pp. 841-843
    • Zins, M.1    Vilgrain, V.2    Gayno, S.3
  • 13
    • 0027133447 scopus 로고
    • Blinded comparison of biopsy needles and automated devices in vitro: I. Biopsy of diffuse hepatic disease
    • Hopper KD, Abendroth CS, Sturtz KW, Matthews YL, Shirk SJ, Stevens LA. Blinded comparison of biopsy needles and automated devices in vitro: I. Biopsy of diffuse hepatic disease. AJR 1993; 161: 1293-7.
    • (1993) AJR , vol.161 , pp. 1293-1297
    • Hopper, K.D.1    Abendroth, C.S.2    Sturtz, K.W.3    Matthews, Y.L.4    Shirk, S.J.5    Stevens, L.A.6
  • 16
    • 0023780233 scopus 로고
    • CT- or sonography-guided biopsy of the liver in the presence of ascites: Frequency of complications
    • Murphy FB, Barefield KP, Steinberg HV, Bernardino ME. CT- or sonography-guided biopsy of the liver in the presence of ascites: Frequency of complications. AJR 1988; 151: 485-6.
    • (1988) AJR , vol.151 , pp. 485-486
    • Murphy, F.B.1    Barefield, K.P.2    Steinberg, H.V.3    Bernardino, M.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.