-
1
-
-
0027096991
-
A CAD CAM method for custom below-knee sockets
-
ENGSBERG JR, CLYNCH GS, LEE AG, ALLAN JS, HARDER JA (1992). A CAD CAM method for custom below-knee sockets- Prosthet Orthot Int 16, 183-188.
-
(1992)
Prosthet Orthot Int
, vol.16
, pp. 183-188
-
-
Engsberg, J.R.1
Clynch, G.S.2
Lee, A.G.3
Allan, J.S.4
Harder, J.A.5
-
2
-
-
0026924741
-
Automated fabncation of mobility aids (AFMA): Below-knee CASD CAM testing and evaluation program results
-
HOUSTON VL, BURGESS EM, CHILDRESS DS, LEHNEIS HR, MASON CP, GARBARINI MA, LABLANC KP, BOONE DA, CHAN RB, HARLAN JH, BRNCICK MD (1992). Automated fabncation of mobility aids (AFMA): below-knee CASD CAM testing and evaluation program results. J Rehabil Res Dev 29(4), 78-124
-
(1992)
J Rehabil Res Dev
, vol.29
, Issue.4
, pp. 78-124
-
-
Houston, V.L.1
Burgess, E.M.2
Childress, D.S.3
Lehneis, H.R.4
Mason, C.P.5
Garbarini, M.A.6
Lablanc, K.P.7
Boone, D.A.8
Chan, R.B.9
Harlan, J.H.10
Brncick, M.D.11
-
3
-
-
0000701784
-
A computerized method for the design of above-knee prosthetic sockets
-
KROUSKOP TA, MAUNAUSKAS M, WILLIAMS J, BARRY PA, MUILENBURG AL, WINNINGHAM DJ (1989). A computerized method for the design of above-knee prosthetic sockets. J Prosthet Orthot 3(1), 131-138.
-
(1989)
J Prosthet Orthot
, vol.3
, Issue.1
, pp. 131-138
-
-
Krouskop, T.A.1
Maunauskas, M.2
Williams, J.3
Barry, P.A.4
Muilenburg, A.L.5
Winningham, D.J.6
-
4
-
-
0027732056
-
Clinical evaluation of trans-tibial prosthesis sockets: A comparison between CAD CAM and conventionally produced sockets
-
OBERG T, LILJA M, JOHANNSSON T, KARSZNIA A (1993). Clinical evaluation of trans-tibial prosthesis sockets: a comparison between CAD CAM and conventionally produced sockets. Prosthet Orthot Int 17, 164-171
-
(1993)
Prosthet Orthot int
, vol.17
, pp. 164-171
-
-
Oberg, T.1
Lilja, M.2
Johannsson, T.3
Karsznia, A.4
-
5
-
-
9444263429
-
Computer aided conception of Cheneau-Toulouse-Munster scoliosis braces: Quantitative valuation by comparison with classical craftsman devices
-
RAMOS JV, PELLAS F, VITTON JM, ABELARD P, CONIL JL, DELARQUE A, BARDOT A (1992). Computer aided conception of Cheneau-Toulouse-Munster scoliosis braces: quantitative valuation by comparison with classical craftsman devices. Clin Rehabil 6, (suppl), 76.
-
(1992)
Clin Rehabil
, vol.6
, Issue.SUPPL.
, pp. 76
-
-
Ramos, J.V.1
Pellas, F.2
Vitton, J.M.3
Abelard, P.4
Conil, J.L.5
Delarque, A.6
Bardot, A.7
-
6
-
-
9444237129
-
-
Procedures In: Abstracts; ISPO VI World Congress, Kobe, Japan 12-17 November 1989. ISPO
-
RASHKE SU (1989). Applications for Spinal Orthotics. Procedures in: Abstracts; ISPO VI World Congress, Kobe, Japan 12-17 November 1989. ISPO. p268.
-
(1989)
Applications for Spinal Orthotics
, pp. 268
-
-
Rashke, S.U.1
-
7
-
-
9444239531
-
CAD CAM Applications for Spinal Orthotics - A Preliminary Investigation
-
RASHKE SU, BANNON MA, SAUNDERS CG, MCGUINESS WJ (1990). CAD CAM Applications for Spinal Orthotics - A Preliminary Investigation. J Prosthet Orthot 2(2), 115-118.
-
(1990)
J Prosthet Orthot
, vol.2
, Issue.2
, pp. 115-118
-
-
Rashke, S.U.1
Bannon, M.A.2
Saunders, C.G.3
Mcguiness, W.J.4
|