메뉴 건너뛰기




Volumn 23, Issue 9, 1996, Pages 1551-1558

Monte Carlo simulation of a miniature, radiosurgery x-ray tube using the ITS 3.0 coupled electron-photon transport code

Author keywords

[No Author keywords available]

Indexed keywords

ANGULAR DISTRIBUTION; INTELLIGENT VEHICLE HIGHWAY SYSTEMS; PHANTOMS; PHOTONS; X RAY PRODUCTION; X RAY TUBES;

EID: 0029810298     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597885     Document Type: Article
Times cited : (38)

References (21)
  • 3
    • 85027233330 scopus 로고
    • Brachytherapy with a miniature x-ray source in brain metastases
    • abstract
    • R. F. Valenzuela, F. H. Hochberg, G. R. Cosgrove, and F. Pardo, "Brachytherapy with a miniature x-ray source in brain metastases," Neurology 44, A217 (abstract) (1994).
    • (1994) Neurology , vol.44
    • Valenzuela, R.F.1    Hochberg, F.H.2    Cosgrove, G.R.3    Pardo, F.4
  • 9
    • 0025938356 scopus 로고
    • Electron-photon Monte Carlo calculations: The ETRAN code
    • S. M. Seltzer, "Electron-photon Monte Carlo calculations: The ETRAN code," Appl. Radiat. Isotopes 42, 917-941 (1991).
    • (1991) Appl. Radiat. Isotopes , vol.42 , pp. 917-941
    • Seltzer, S.M.1
  • 10
    • 33744555959 scopus 로고
    • personal communication
    • S. M. Seltzer (personal communication, 1994).
    • (1994)
    • Seltzer, S.M.1
  • 11
    • 0002571923 scopus 로고
    • Electron step-size artefacts and PRESTA
    • edited by T. M. Jenkins, W. R. Nelson, and A. Rindi Plenum, New York
    • A. F. Bielajew and D. W. O. Rogers, "Electron step-size artefacts and PRESTA," in Monte Carlo Transport of Electrons and Photons, edited by T. M. Jenkins, W. R. Nelson, and A. Rindi (Plenum, New York, 1988).
    • (1988) Monte Carlo Transport of Electrons and Photons
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 15
    • 33744613288 scopus 로고    scopus 로고
    • personal communication
    • J. A. Halbleib (personal communication, 1996).
    • (1996)
    • Halbleib, J.A.1
  • 17
    • 0020137053 scopus 로고
    • A solid water phantom material for radiotherapy x-ray and gamma-ray beam calibrations
    • C. Constantinou, F. H. Attix, and B. R. Patiwal, "A solid water phantom material for radiotherapy x-ray and gamma-ray beam calibrations," Med. Phys. 9, 436 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 436
    • Constantinou, C.1    Attix, F.H.2    Patiwal, B.R.3
  • 18
    • 33744664427 scopus 로고
    • Precision of output calibration in air and water of a miniature x-ray tube
    • abstract
    • J. Beatty, P. Biggs, and T. Yasuda, "Precision of output calibration in air and water of a miniature x-ray tube," Med. Phys. 22, 968 (abstract) (1995).
    • (1995) Med. Phys. , vol.22 , pp. 968
    • Beatty, J.1    Biggs, P.2    Yasuda, T.3
  • 19
    • 0024914777 scopus 로고
    • Comparison of experimental pulse-height distributions in germanium detectors with Integrated Tiger-Series-code predictions
    • December
    • D E. Beutler, J. A Halbleib, and D. P. Knott, "Comparison of experimental pulse-height distributions in germanium detectors with Integrated Tiger-Series-code predictions," IEEE Trans. Nucl. Sci NS-36, 1912-1919 (December 1989).
    • (1989) IEEE Trans. Nucl. Sci , vol.NS-36 , pp. 1912-1919
    • Beutler, D.E.1    Halbleib, J.A.2    Knott, D.P.3
  • 20
    • 33744600365 scopus 로고
    • personal communication
    • J. A. Rathkopf (personal communication, 1994)
    • (1994)
    • Rathkopf, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.