메뉴 건너뛰기




Volumn 33, Issue 5, 1996, Pages 257-261

Axial length estimation in strabismic patients

Author keywords

[No Author keywords available]

Indexed keywords

A SCAN; ARTICLE; CHILD; EYE AXIS LENGTH; HUMAN; MAJOR CLINICAL STUDY; REFRACTION ERROR; STRABISMUS;

EID: 0029810080     PISSN: 01913913     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (12)
  • 2
    • 0024466721 scopus 로고
    • The influence of axial length on the response to strabismus surgery
    • Kushner BJ, Lucchese NJ, Morton GV. The influence of axial length on the response to strabismus surgery. Arch Ophthalmol. 1989;107:1616-1618.
    • (1989) Arch Ophthalmol , vol.107 , pp. 1616-1618
    • Kushner, B.J.1    Lucchese, N.J.2    Morton, G.V.3
  • 3
    • 0028372672 scopus 로고
    • Effect of bulbous length of reduction of squint angle after suture fixation
    • Krzizolc T, Graf M, Kaufmann H. Effect of bulbous length of reduction of squint angle after suture fixation. Ophthalmologe. 1994;91(1):68-76.
    • (1994) Ophthalmologe , vol.91 , Issue.1 , pp. 68-76
    • Krzizolc, T.1    Graf, M.2    Kaufmann, H.3
  • 4
    • 0023277385 scopus 로고
    • Theoretical effects of surgery on length-tension relationships in extraocular muscles
    • Kushner BJ, Brabec M. Theoretical effects of surgery on length-tension relationships in extraocular muscles. J Pediatr Ophthalmol Strabismus. 1987;28:126-131.
    • (1987) J Pediatr Ophthalmol Strabismus , vol.28 , pp. 126-131
    • Kushner, B.J.1    Brabec, M.2
  • 5
    • 0019409434 scopus 로고
    • Measurement of strabismus eyes with A-scan ultrasonography
    • Gillies WE, McIndoe A. Measurement of strabismus eyes with A-scan ultrasonography. Aust J Ophthalmol. 1981;9:231-232.
    • (1981) Aust J Ophthalmol , vol.9 , pp. 231-232
    • Gillies, W.E.1    McIndoe, A.2
  • 6
    • 0020421285 scopus 로고
    • The use of ultrasonography in determining the amount of extraocular muscle surgery in strabismus
    • Gillies WE, McIndoe A. The use of ultrasonography in determining the amount of extraocular muscle surgery in strabismus. Aust J Ophthalmol. 1982;10:191-194.
    • (1982) Aust J Ophthalmol , vol.10 , pp. 191-194
    • Gillies, W.E.1    McIndoe, A.2
  • 7
    • 9544248156 scopus 로고
    • The use of A-scan ultrasonography to design the strabismus operation
    • Reinecke RD, ed. New York, NY: Grune & Stratton;
    • Gillies WE, McIndoe A. The use of A-scan ultrasonography to design the strabismus operation. In: Reinecke RD, ed. Strabismus (vol 2). New York, NY: Grune & Stratton; 1984:659-667.
    • (1984) Strabismus , vol.2 , pp. 659-667
    • Gillies, W.E.1    McIndoe, A.2
  • 8
    • 0021795785 scopus 로고
    • Refractive development of the human eye
    • Gordon RA, Donzis PB. Refractive development of the human eye. Arch Ophthalmol. 1985;103:785-789.
    • (1985) Arch Ophthalmol , vol.103 , pp. 785-789
    • Gordon, R.A.1    Donzis, P.B.2
  • 9
    • 0019432970 scopus 로고
    • The accuracy of ultrasonic measurement of the axial length of the eye
    • Binlchorst RD. The accuracy of ultrasonic measurement of the axial length of the eye. Ophthalmic Surg. 1981;12:363-365.
    • (1981) Ophthalmic Surg , vol.12 , pp. 363-365
    • Binlchorst, R.D.1
  • 10
    • 0026065222 scopus 로고
    • Variation in axial length and landmarks in strabismic patients
    • Kushner BJ, Lucchese NJ, Morton GV. Variation in axial length and landmarks in strabismic patients. Ophthalmology. 1991;98:400-406.
    • (1991) Ophthalmology , vol.98 , pp. 400-406
    • Kushner, B.J.1    Lucchese, N.J.2    Morton, G.V.3
  • 11
    • 0018955290 scopus 로고
    • Improvement of intraocular lens power calculation using empiric data
    • Sanders DR, Kraff MC. Improvement of intraocular lens power calculation using empiric data. Am J Intraocul Implant Soc. 1980;6:263-267.
    • (1980) Am J Intraocul Implant Soc , vol.6 , pp. 263-267
    • Sanders, D.R.1    Kraff, M.C.2
  • 12
    • 0023747545 scopus 로고
    • High axial length/corneal radius ratio as a risk factor in the development of myopia
    • Grosvenor T. High axial length/corneal radius ratio as a risk factor in the development of myopia. American Journal of Optometry and Physiological Optics. 1988;65:689-696.
    • (1988) American Journal of Optometry and Physiological Optics , vol.65 , pp. 689-696
    • Grosvenor, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.