메뉴 건너뛰기




Volumn 6, Issue 2, 1996, Pages 73-90

Histologic analysis of the periprosthetic tissues of long-term surviving cemented total hip arthroplasties

Author keywords

biomaterials; cemented total hip arthroplasty; interfacial membrane; prosthetic wear particles

Indexed keywords

BIOMATERIALS; CEMENTS; HIP PROSTHESES; JOINTS (ANATOMY); MEMBRANES; METALS; PARTICLES (PARTICULATE MATTER); POLYETHYLENES;

EID: 0029809143     PISSN: 10506934     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (79)
  • 1
    • 0018088005 scopus 로고
    • Materialverschleiss und Gewebereaktion bei klinischen Gelenken
    • Willert, H. G., Semlitsch, M., Buchhorn, G., and Kriete, U., Materialverschleiss und Gewebereaktion bei klinischen Gelenken, Orthopäde, 1978; 7:62-83.
    • (1978) Orthopäde , vol.7 , pp. 62-83
    • Willert, H.G.1    Semlitsch, M.2    Buchhorn, G.3    Kriete, U.4
  • 2
    • 9544258669 scopus 로고
    • Greenwald, S., Ed. Tape #6. Cleveland: Mt. Sinai Medical Center
    • Mallory, T. H., Current Concepts in Joint Replacement. In: Greenwald, S., Ed. Tape #6. Cleveland: Mt. Sinai Medical Center, 1988.
    • (1988) Current Concepts in Joint Replacement
    • Mallory, T.H.1
  • 5
    • 0025254587 scopus 로고
    • Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation
    • Willert, H. G., Bertram, H., and Buchhorn, G. H., Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation, Clin. Orthop., 1990; 258:108-121.
    • (1990) Clin. Orthop. , vol.258 , pp. 108-121
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3
  • 6
    • 0027221789 scopus 로고
    • Cemented versus cementless total hip arthroplasty. A comparative study of equivalent patient populations
    • Hozack, W. J., Rothman, R. H., Booth, R. E., Jr., and Balderston, R. A., Cemented versus cementless total hip arthroplasty. A comparative study of equivalent patient populations, Clin. Orthop., 1993; 289:161-165.
    • (1993) Clin. Orthop. , vol.289 , pp. 161-165
    • Hozack, W.J.1    Rothman, R.H.2    Booth Jr., R.E.3    Balderston, R.A.4
  • 7
    • 0026605415 scopus 로고
    • The scientific basis of cement versus cementless fixation
    • Freeman, M. A. R. and Tennant, R., The scientific basis of cement versus cementless fixation, Clin. Orthop., 1992; 276:19-25.
    • (1992) Clin. Orthop. , vol.276 , pp. 19-25
    • Freeman, M.A.R.1    Tennant, R.2
  • 8
    • 0019955716 scopus 로고
    • The pathology of failed total joint arthroplasty
    • Mirra, J. M., Marder, R. A., and Amstutz, H. C., The pathology of failed total joint arthroplasty, Clin. Orthop., 1982; 170:175-185.
    • (1982) Clin. Orthop. , vol.170 , pp. 175-185
    • Mirra, J.M.1    Marder, R.A.2    Amstutz, H.C.3
  • 9
    • 0020576705 scopus 로고
    • The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
    • Goldring, S. R., Schiller, A. L., Roelke, M., Bourke, C. M., O'Neill, D. A., and Harris, W. H., The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis, J. Bone Joint Surg., 1983; 65A:575-584.
    • (1983) J. Bone Joint Surg. , vol.65 A , pp. 575-584
    • Goldring, S.R.1    Schiller, A.L.2    Roelke, M.3    Bourke, C.M.4    O'Neill, D.A.5    Harris, W.H.6
  • 10
    • 0023196425 scopus 로고
    • The microscopic anatomy of the bone-cement interface in failed total hip arthroplasties
    • Johanson, N. A., Bullough, P. G., Wilsson, P. D., Jr., Salvati, E. A., and Ranawat, C. S., The microscopic anatomy of the bone-cement interface in failed total hip arthroplasties, Clin. Orthop., 1987; 218:123-135.
    • (1987) Clin. Orthop. , vol.218 , pp. 123-135
    • Johanson, N.A.1    Bullough, P.G.2    Wilsson Jr., P.D.3    Salvati, E.A.4    Ranawat, C.S.5
  • 11
    • 0027060320 scopus 로고
    • Histomorphological reaction patterns of the bone to diverse particulate implant materials in man and experimental animals
    • St John, K. R., Ed. ASTM STP 1144. Philadelphia: American Society for Testing and Materials
    • Boss, J. H., Shajrawi, I., Soudry, M., and Mendes, D. G., Histomorphological reaction patterns of the bone to diverse particulate implant materials in man and experimental animals. In: St John, K. R., Ed. Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences, ASTM STP 1144. Philadelphia: American Society for Testing and Materials, 1992; 90-108.
    • (1992) Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences , pp. 90-108
    • Boss, J.H.1    Shajrawi, I.2    Soudry, M.3    Mendes, D.G.4
  • 12
    • 0020782315 scopus 로고
    • Biochemical features of pseudomembrane at the bone-cement interface of loosened total hip prostheses
    • Shoji, H., Karube, S., D'ambrosia, R. D., Dabezies, E. J., and Miller, D. R., Biochemical features of pseudomembrane at the bone-cement interface of loosened total hip prostheses, J. Biomed. Mater. Res., 1983; 17:669-678.
    • (1983) J. Biomed. Mater. Res. , vol.17 , pp. 669-678
    • Shoji, H.1    Karube, S.2    D'ambrosia, R.D.3    Dabezies, E.J.4    Miller, D.R.5
  • 13
    • 0025676497 scopus 로고
    • Histological features of the interface membrane of failed isoelastic cementless prostheses
    • Boss, J. H., Shajrawi, M., Soudry, M., and Mendes, D. G., Histological features of the interface membrane of failed isoelastic cementless prostheses, Intern. Orthop., 1990; 14:399-403.
    • (1990) Intern. Orthop. , vol.14 , pp. 399-403
    • Boss, J.H.1    Shajrawi, M.2    Soudry, M.3    Mendes, D.G.4
  • 14
    • 0027383408 scopus 로고
    • Lysosomal enzyme production at the interface surrounding loose and well-fixed cemented tibial hemiarthroplasties in the rabbit knee
    • Goodman, S. B., Kang, T., and Smith, R. L., Lysosomal enzyme production at the interface surrounding loose and well-fixed cemented tibial hemiarthroplasties in the rabbit knee, J. Invest. Surg., 1993; 6:413-418.
    • (1993) J. Invest. Surg. , vol.6 , pp. 413-418
    • Goodman, S.B.1    Kang, T.2    Smith, R.L.3
  • 15
    • 84947381024 scopus 로고
    • The bone-cement interface: Histological observations on the interface of cemented arthroplasties within the immediate and late phases
    • Boss, J. H., Shajrawi, I., Dekel, S., and Mendes, D. G., The bone-cement interface: Histological observations on the interface of cemented arthroplasties within the immediate and late phases, J. Biomater. Sci Polymer Edn., 1993; 3:221-230.
    • (1993) J. Biomater. Sci Polymer Edn. , vol.3 , pp. 221-230
    • Boss, J.H.1    Shajrawi, I.2    Dekel, S.3    Mendes, D.G.4
  • 16
    • 0025679122 scopus 로고
    • Histological, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty
    • Dorr, L. D., Bloebaum, R., Emmanuel, J., and Meldrum, J., Histological, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty, Clin. Orthop., 1990; 261:82-95.
    • (1990) Clin. Orthop. , vol.261 , pp. 82-95
    • Dorr, L.D.1    Bloebaum, R.2    Emmanuel, J.3    Meldrum, J.4
  • 18
    • 0022505501 scopus 로고
    • Observations on the fixation of implants to the bony skeleton
    • Ling, R. S. M., Observations on the fixation of implants to the bony skeleton, Clin. Orthop., 1986; 210:80-96.
    • (1986) Clin. Orthop. , vol.210 , pp. 80-96
    • Ling, R.S.M.1
  • 20
    • 0029278592 scopus 로고
    • The relativity of biocompatibility. A critique of the concept of biocompatibility
    • Boss, J. H., Shajrawi, I., Aunullah, J. M., and Mendes, D. G., The relativity of biocompatibility. A critique of the concept of biocompatibility, Isr. J. Med. Sci., 1995; 31:203-209.
    • (1995) Isr. J. Med. Sci. , vol.31 , pp. 203-209
    • Boss, J.H.1    Shajrawi, I.2    Aunullah, J.M.3    Mendes, D.G.4
  • 21
    • 0028020496 scopus 로고
    • The nature of bone-implant interface: The lessons learned from implant retrieval and analysis in man and experimental animal
    • Boss, J. H., Shajrawi, I., and Mendes, D. G., The nature of bone-implant interface: The lessons learned from implant retrieval and analysis in man and experimental animal, Med. Progr. Through Technology, 1994; 20:119-142.
    • (1994) Med. Progr. Through Technology , vol.20 , pp. 119-142
    • Boss, J.H.1    Shajrawi, I.2    Mendes, D.G.3
  • 23
    • 0001931284 scopus 로고
    • Preparation of calcified tissues for light microscopy
    • Dickson, G. R., Ed. Amsterdam: Elsevier Science Publishers
    • Schenk, R. K., Olah, A. J., and Hermann, W., Preparation of calcified tissues for light microscopy. In: Dickson, G. R., Ed. Methods of Calcified Tissue Preparation, Amsterdam: Elsevier Science Publishers, 1984, 184-214.
    • (1984) Methods of Calcified Tissue Preparation , pp. 184-214
    • Schenk, R.K.1    Olah, A.J.2    Hermann, W.3
  • 24
    • 0027400764 scopus 로고
    • A histologic and biochemical comparison of the interface tissues in cementless and cemented hip prostheses
    • Kim, K. J., Rubashi, H. E., Wilson, S. C., D'Antonio, J. A., and McClain, E. J., A histologic and biochemical comparison of the interface tissues in cementless and cemented hip prostheses, Clin. Orthop., 1993; 287:142-152.
    • (1993) Clin. Orthop. , vol.287 , pp. 142-152
    • Kim, K.J.1    Rubashi, H.E.2    Wilson, S.C.3    D'Antonio, J.A.4    McClain, E.J.5
  • 25
    • 0027619417 scopus 로고
    • Histologic identification of polyethylene debris using oil red O stain
    • Schmalzried, T. P., Jasty, M., Rosenberg, A., and Harris, W. H., Histologic identification of polyethylene debris using oil red O stain, J. Appl. Biomater., 1993; 4:119-125.
    • (1993) J. Appl. Biomater. , vol.4 , pp. 119-125
    • Schmalzried, T.P.1    Jasty, M.2    Rosenberg, A.3    Harris, W.H.4
  • 26
    • 0028459911 scopus 로고
    • Effects of intermittent micromotion versus polymer particles on tissue ingrowth: Experiment using a micromotion chamber implanted in rabbits
    • Goodman, S., Aspenberg, P., Song, Y., Regula, D., Jr., Doshi, A., and Lidgren, L., Effects of intermittent micromotion versus polymer particles on tissue ingrowth: Experiment using a micromotion chamber implanted in rabbits, J. Appl. Biomater., 1994; 5:117-123.
    • (1994) J. Appl. Biomater. , vol.5 , pp. 117-123
    • Goodman, S.1    Aspenberg, P.2    Song, Y.3    Regula Jr., D.4    Doshi, A.5    Lidgren, L.6
  • 28
    • 0026588287 scopus 로고
    • Current status of acetabular fixation in primary total hip arthroplasty
    • Morscher, E. W., Current status of acetabular fixation in primary total hip arthroplasty, Clin. Orthop., 1992; 274:172-193.
    • (1992) Clin. Orthop. , vol.274 , pp. 172-193
    • Morscher, E.W.1
  • 29
    • 0023778434 scopus 로고
    • Development and first experience with an uncemented press-fit cup
    • Morscher, E. and Masar, Z., Development and first experience with an uncemented press-fit cup, Clin. Orthop., 1988; 232:96-102.
    • (1988) Clin. Orthop. , vol.232 , pp. 96-102
    • Morscher, E.1    Masar, Z.2
  • 33
    • 0028258952 scopus 로고
    • Combined survivorship and multivariate analyses of revisions in 799 hip prostheses. A 10- to 20-year review of mechanical loosening
    • Johnsson, R., Franzén, H., and Nilsson, L. T., Combined survivorship and multivariate analyses of revisions in 799 hip prostheses. A 10- to 20-year review of mechanical loosening, J. Bone Joint Surg., 1994; 76B:439-443.
    • (1994) J. Bone Joint Surg. , vol.76 B , pp. 439-443
    • Johnsson, R.1    Franzén, H.2    Nilsson, L.T.3
  • 34
    • 0026695452 scopus 로고
    • The femoral component in low-friction arthroplasty after ten years
    • Munuera, L. and Garcia-Cimbrelo, E., The femoral component in low-friction arthroplasty after ten years, Clin. Orthop., 1992; 279:163-175.
    • (1992) Clin. Orthop. , vol.279 , pp. 163-175
    • Munuera, L.1    Garcia-Cimbrelo, E.2
  • 36
    • 0000013243 scopus 로고
    • Periprosthetic femoral fractures
    • Kelley, S. S., Periprosthetic femoral fractures, J. Amer. Acad. Orthop. Surg., 1994; 2:164-172.
    • (1994) J. Amer. Acad. Orthop. Surg. , vol.2 , pp. 164-172
    • Kelley, S.S.1
  • 37
    • 0025047558 scopus 로고
    • Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties
    • Anthony, P. P., Gie, G. A., Howie, C. R., and Ling, R. S. M., Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties, J. Bone Joint Surg., 1990; 72B:971-979.
    • (1990) J. Bone Joint Surg. , vol.72 B , pp. 971-979
    • Anthony, P.P.1    Gie, G.A.2    Howie, C.R.3    Ling, R.S.M.4
  • 38
    • 0028006686 scopus 로고
    • Supracondylar fracture of the femur associated with polyethylene wear after total knee arthroplasty. A case report
    • Rand, J. A., Supracondylar fracture of the femur associated with polyethylene wear after total knee arthroplasty. A case report, J. Bone Joint Surg., 1994; 76A:1389-1393.
    • (1994) J. Bone Joint Surg. , vol.76 A , pp. 1389-1393
    • Rand, J.A.1
  • 39
    • 0026464503 scopus 로고
    • Charnley low-friction arthroplasty in the young patient
    • Wroblewski, B. M. and Siney, P. D., Charnley low-friction arthroplasty in the young patient, Clin. Orthop., 1992; 285:45-47.
    • (1992) Clin. Orthop. , vol.285 , pp. 45-47
    • Wroblewski, B.M.1    Siney, P.D.2
  • 40
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried, T. P., Jasty, M., and Harris, W. H., Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space, J. Bone Joint Surg., 1992; 74A:849-863.
    • (1992) J. Bone Joint Surg. , vol.74 A , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 43
    • 0027657468 scopus 로고
    • Comparison of human and canine external femoral morphologies in the context of total hip replacement
    • Bloebaum, R. D., Ota, D. T., Skedros, J. G., and Mantas, J. P., Comparison of human and canine external femoral morphologies in the context of total hip replacement, J. Biomed. Mater. Res., 1993; 27:1149-1159.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 1149-1159
    • Bloebaum, R.D.1    Ota, D.T.2    Skedros, J.G.3    Mantas, J.P.4
  • 44
    • 0029257099 scopus 로고
    • A quantitative technique for reporting surface degradation patterns of UHMWPE components of retrieved total knee replacements
    • Cornwall, G. B., Bryant, J. T., Hansson, C. M., Rudan, J., and Kennedy, L.A., A quantitative technique for reporting surface degradation patterns of UHMWPE components of retrieved total knee replacements, J. Appl. Biomater., 1995; 6:9-18.
    • (1995) J. Appl. Biomater. , vol.6 , pp. 9-18
    • Cornwall, G.B.1    Bryant, J.T.2    Hansson, C.M.3    Rudan, J.4    Kennedy, L.A.5
  • 45
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total joint replacements
    • Wang, A., Sun, D. C., Stark, C., and Dumbleton, J. H., Wear mechanisms of UHMWPE in total joint replacements, Wear, 1995; 181-183:241-249.
    • (1995) Wear , vol.181-183 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 47
    • 0023511578 scopus 로고
    • A histologic comparison of aseptic loosening of cemented, press-fit, and biologic ingrowth prostheses
    • Lennox, D. W., Schofield, B. H., McDonald, D. F., and Riley, L. H., Jr., A histologic comparison of aseptic loosening of cemented, press-fit, and biologic ingrowth prostheses, Clin. Orthop., 1987; 225:171-191.
    • (1987) Clin. Orthop. , vol.225 , pp. 171-191
    • Lennox, D.W.1    Schofield, B.H.2    McDonald, D.F.3    Riley Jr., L.H.4
  • 48
    • 0026530696 scopus 로고
    • A histopathologic study of late aseptic loosening of cemented total hip prostheses
    • Williams, R. P. and McQueen, D. A., A histopathologic study of late aseptic loosening of cemented total hip prostheses, Clin. Orthop., 1992; 275:174-179.
    • (1992) Clin. Orthop. , vol.275 , pp. 174-179
    • Williams, R.P.1    McQueen, D.A.2
  • 49
    • 0021027337 scopus 로고
    • Ultrastructural aspects of the interface between bone and cement in man
    • Linder, L. and Hansson, H. A., Ultrastructural aspects of the interface between bone and cement in man, J. Bone Joint Surg., 1983; 65B:646-649.
    • (1983) J. Bone Joint Surg. , vol.65 B , pp. 646-649
    • Linder, L.1    Hansson, H.A.2
  • 51
    • 0026672302 scopus 로고
    • Biocompatibility of surgical-grade dense polycrystalline alumina
    • Christel, P. S., Biocompatibility of surgical-grade dense polycrystalline alumina, Clin. Orthop., 1992; 282:10-18.
    • (1992) Clin. Orthop. , vol.282 , pp. 10-18
    • Christel, P.S.1
  • 52
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
    • Davidson, J. A., Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear, Clin. Orthop., 1993; 294:361-378.
    • (1993) Clin. Orthop. , vol.294 , pp. 361-378
    • Davidson, J.A.1
  • 53
    • 0023036189 scopus 로고
    • The bone-cement interface in hip arthroplasty. A histologic and enzyme study of stable components
    • Linder, L. and Carlsson, A. S., The bone-cement interface in hip arthroplasty. A histologic and enzyme study of stable components, Acta Orthop. Scand., 1986; 57:495-500.
    • (1986) Acta Orthop. Scand. , vol.57 , pp. 495-500
    • Linder, L.1    Carlsson, A.S.2
  • 54
    • 0022532235 scopus 로고
    • Excessive metal release due to loosening and fretting of sintered particles on porous-coated hip prostheses
    • Buchert, P. K., Vaughin, B. K., Mallory, T. H., Engh, C. A., and Bobyn, D., Excessive metal release due to loosening and fretting of sintered particles on porous-coated hip prostheses, J. Bone Joint Surg., 1986; 68A:606-609.
    • (1986) J. Bone Joint Surg. , vol.68 A , pp. 606-609
    • Buchert, P.K.1    Vaughin, B.K.2    Mallory, T.H.3    Engh, C.A.4    Bobyn, D.5
  • 55
    • 0025886919 scopus 로고
    • Black staining around titanium alloy prostheses - An orthopædic enigma
    • Scales, J. T., Black staining around titanium alloy prostheses - an orthopædic enigma, J. Bone Joint Surg., 1991; 73B:534-536.
    • (1991) J. Bone Joint Surg. , vol.73 B , pp. 534-536
    • Scales, J.T.1
  • 56
    • 1542560803 scopus 로고
    • Necrotizing granulomas within the periprosthetic tissues of cemented and cemented total arthroplasties
    • Boss, J. H., Shajrawi, I., Luria, M., and Mendes, D. G., Necrotizing granulomas within the periprosthetic tissues of cemented and cemented total arthroplasties, Vet. Comp. Orthop. Traumatol., 1995; 8:107-113.
    • (1995) Vet. Comp. Orthop. Traumatol. , vol.8 , pp. 107-113
    • Boss, J.H.1    Shajrawi, I.2    Luria, M.3    Mendes, D.G.4
  • 57
    • 0025137538 scopus 로고
    • Metallosis associated with stable titanium-alloy femoral component in total hip replacement. A case report
    • Black, J., Sherk, H., Bonini, J., Rostoker, W. R., Schajowicz, F., and Galante, J. O., Metallosis associated with stable titanium-alloy femoral component in total hip replacement. A case report, J. Bone Joint Surg., 1990; 72A:126-130.
    • (1990) J. Bone Joint Surg. , vol.72 A , pp. 126-130
    • Black, J.1    Sherk, H.2    Bonini, J.3    Rostoker, W.R.4    Schajowicz, F.5    Galante, J.O.6
  • 58
    • 0026490462 scopus 로고
    • Debris from cobalt-chrome cable may cause acetabular loosening
    • Kelley, S. S. and Johnston, R. C., Debris from cobalt-chrome cable may cause acetabular loosening, Clin. Orthop., 1992; 285:140-146.
    • (1992) Clin. Orthop. , vol.285 , pp. 140-146
    • Kelley, S.S.1    Johnston, R.C.2
  • 59
    • 0027368313 scopus 로고
    • Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement: Report of a case
    • Huo, M. H., Betts, F., Bogumill, G. P., Kenmore, P. I., Hajek, R. J., and Martinelli, T. J., Metallic wear debris in acetabular osteolysis in a mechanically stable cementless total hip replacement: Report of a case, Orthopedics, 1993; 11:1277-1281.
    • (1993) Orthopedics , vol.11 , pp. 1277-1281
    • Huo, M.H.1    Betts, F.2    Bogumill, G.P.3    Kenmore, P.I.4    Hajek, R.J.5    Martinelli, T.J.6
  • 60
    • 0026863992 scopus 로고
    • Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty
    • Cheal, E. J., Spector, M., and Hayes, W. C., Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty, J. Orthop. Res., 1992; 10:405-422.
    • (1992) J. Orthop. Res. , vol.10 , pp. 405-422
    • Cheal, E.J.1    Spector, M.2    Hayes, W.C.3
  • 61
    • 0027255292 scopus 로고
    • Survivorship analysis of cemented high modulus total hip arthroplasty
    • Bosco, J. A., Machiewicz, P. F., and DeMasi, R., Survivorship analysis of cemented high modulus total hip arthroplasty, Clin. Orthop., 1993; 294:131-139.
    • (1993) Clin. Orthop. , vol.294 , pp. 131-139
    • Bosco, J.A.1    Machiewicz, P.F.2    Demasi, R.3
  • 62
    • 9544256081 scopus 로고
    • The pathology of the interface membrane in prosthetic failure after total hip replacement
    • Boss, J. H., The pathology of the interface membrane in prosthetic failure after total hip replacement, Isr. J. Med. Sci, 1983; 19:1116.
    • (1983) Isr. J. Med. Sci , vol.19 , pp. 1116
    • Boss, J.H.1
  • 64
    • 4243716451 scopus 로고
    • The morphological patterns of organization of synthetic filamentous prostheses in reconstructive orthopædic surgery
    • Wise, D. L., Trantolo, D. J., Altobelli, D. E., Yaszemski, M. J., Gresser, J. D., and Schwartz, E. D., Eds. New York, Basel, Hong Kong: Marcel Dekker, Inc.
    • Mendes, D. G., and Boss, J. H., The morphological patterns of organization of synthetic filamentous prostheses in reconstructive orthopædic surgery. In: Wise, D. L., Trantolo, D. J., Altobelli, D. E., Yaszemski, M. J., Gresser, J. D., and Schwartz, E. D., Eds. Encyclopedic Handbook of Biomaterials and Bioengineering, New York, Basel, Hong Kong: Marcel Dekker, Inc., 1995, 383-414.
    • (1995) Encyclopedic Handbook of Biomaterials and Bioengineering , pp. 383-414
    • Mendes, D.G.1    Boss, J.H.2
  • 65
    • 0026782890 scopus 로고
    • Comparison of alumina-polyethylene and metal-polyethylene in clinical trials
    • Zichner, P. and Willert, H. G., Comparison of alumina-polyethylene and metal-polyethylene in clinical trials, Clin. Orthop., 1992; 282:86-94.
    • (1992) Clin. Orthop. , vol.282 , pp. 86-94
    • Zichner, P.1    Willert, H.G.2
  • 66
    • 0018537364 scopus 로고
    • Contact pressure dependence of wear rates of ultra high molecular weight polyethylene
    • Rostoker, W. and Galante, J. O., Contact pressure dependence of wear rates of ultra high molecular weight polyethylene, J. Biomed. Mater. Res., 1979; 13:957-964.
    • (1979) J. Biomed. Mater. Res. , vol.13 , pp. 957-964
    • Rostoker, W.1    Galante, J.O.2
  • 67
    • 0028108743 scopus 로고
    • The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old
    • Ballard, W. T., Callaghan, J. J., Sullivan, P. M., and Johnston, R. C., The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old, J. Bone Joint Surg., 1994; 76A:959-964.
    • (1994) J. Bone Joint Surg. , vol.76 A , pp. 959-964
    • Ballard, W.T.1    Callaghan, J.J.2    Sullivan, P.M.3    Johnston, R.C.4
  • 68
    • 0028121998 scopus 로고
    • The femoral component in total hip arthroplasty. Six- to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique
    • Oishi, C. S., Walker, R. H., and Colwell, C. W., Jr., The femoral component in total hip arthroplasty. Six- to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique, J. Bone Joint Surg., 1994; 76A:1130-1136.
    • (1994) J. Bone Joint Surg. , vol.76 A , pp. 1130-1136
    • Oishi, C.S.1    Walker, R.H.2    Colwell Jr., C.W.3
  • 69
    • 0029061086 scopus 로고
    • Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups
    • Wang, A., Stark, C., and Dumbleton, J. H., Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups, J. Biomed. Mater. Res., 1995; 29:619-626.
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 619-626
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 70
    • 0026550681 scopus 로고
    • Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal contents and associated histologic findings
    • Betts, F., Wright, T, Salvati, E. A., Boskey, A., and Bansal, M., Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal contents and associated histologic findings, Clin. Orthop., 1992; 276:75-82.
    • (1992) Clin. Orthop. , vol.276 , pp. 75-82
    • Betts, F.1    Wright, T.2    Salvati, E.A.3    Boskey, A.4    Bansal, M.5
  • 71
    • 0028258951 scopus 로고
    • Titanium: Epitome of biocompatibility or cause for concern
    • Williams, D. F., Titanium: epitome of biocompatibility or cause for concern, J. Bone Joint Surg., 1994; 76B:348-349.
    • (1994) J. Bone Joint Surg. , vol.76 B , pp. 348-349
    • Williams, D.F.1
  • 73
    • 0026956713 scopus 로고
    • Severe metallosis observed 17 years after replacement of the knee with a tumor prosthesis: A case report
    • Matsuda, Y., Yamamuro, T., Kotoura, Y., and Fukumoto, A., Severe metallosis observed 17 years after replacement of the knee with a tumor prosthesis: A case report, J. Long-Term Eff. Med. Implants, 1992; 1:295-303.
    • (1992) J. Long-Term Eff. Med. Implants , vol.1 , pp. 295-303
    • Matsuda, Y.1    Yamamuro, T.2    Kotoura, Y.3    Fukumoto, A.4
  • 74
    • 0026603286 scopus 로고
    • The lessons of 30 years of total hip arthroplasty
    • Müller, M. E., The lessons of 30 years of total hip arthroplasty, Clin. Orthop., 1992; 274:12-21.
    • (1992) Clin. Orthop. , vol.274 , pp. 12-21
    • Müller, M.E.1
  • 75
    • 0028214945 scopus 로고
    • Stanmore total hip replacement. A 15- to 16-year clinical and radiographic follow-up
    • Alsema, R., Deutman, R., and Muldr, Th.J., Stanmore total hip replacement. A 15- to 16-year clinical and radiographic follow-up, J. Bone Joint Surg., 1994; 76B:240-244.
    • (1994) J. Bone Joint Surg. , vol.76 B , pp. 240-244
    • Alsema, R.1    Deutman, R.2    Muldr, T.J.3
  • 76
    • 0028034860 scopus 로고
    • Does early migration of femora stem prostheses matter? 4- to 7-year stereoradiographic follow-up of 84 cemented prostheses
    • Kärrholm, J., Borssén, B., Löwenhielm, G., and Snorrason, F., Does early migration of femora stem prostheses matter? 4- to 7-year stereoradiographic follow-up of 84 cemented prostheses, J. Bone Joint Surg., 1994; 76B:912-917.
    • (1994) J. Bone Joint Surg. , vol.76 B , pp. 912-917
    • Kärrholm, J.1    Borssén, B.2    Löwenhielm, G.3    Snorrason, F.4
  • 77
    • 9544232966 scopus 로고
    • Design rationale of interference-fit total hip prostheses
    • Fitzgerald, R., Jr., Ed. New York: Raven Press
    • Oh, I., Design rationale of interference-fit total hip prostheses. In: Fitzgerald, R., Jr., Ed. Non-Cemented Total Hip Arthroplasty, New York: Raven Press, 1988; 365-379.
    • (1988) Non-Cemented Total Hip Arthroplasty , pp. 365-379
    • Oh, I.1
  • 79
    • 0029020276 scopus 로고
    • Tissue ingrowth and differentiation in the bone-harvest chamber in the presence of cobalt-chromium alloy and high-density-polyethylene particles
    • Goodman, S., Aspenberg, P., Song, Y., Knoblich, G., Regula, D., and Lidgren, L., Tissue ingrowth and differentiation in the bone-harvest chamber in the presence of cobalt-chromium alloy and high-density-polyethylene particles. J. Bone Joint Surg., 1995; 77A:1025-1035.
    • (1995) J. Bone Joint Surg. , vol.77 A , pp. 1025-1035
    • Goodman, S.1    Aspenberg, P.2    Song, Y.3    Knoblich, G.4    Regula, D.5    Lidgren, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.