메뉴 건너뛰기




Volumn 11, Issue 3, 1996, Pages 241-245

Surface coating of cardiopulmonary bypass circuits

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIAL; HEPARIN; PHOSPHOLIPID; POLYCARBONATE;

EID: 0029797578     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1177/026765919601100309     Document Type: Conference Paper
Times cited : (8)

References (23)
  • 2
    • 0023797386 scopus 로고
    • A compliant small diameter vascular prosthesis lined with functional venous endothelial cells
    • Müller-Glauser W, Lehmann KH, Bittmann P et al. A compliant small diameter vascular prosthesis lined with functional venous endothelial cells. Trans Am Soc Artif Intern Organs 1988; 34: 528-31.
    • (1988) Trans Am Soc Artif Intern Organs , vol.34 , pp. 528-531
    • Müller-Glauser, W.1    Lehmann, K.H.2    Bittmann, P.3
  • 3
    • 0028033097 scopus 로고
    • Superior late patency of small diameter Dacron grafts seeded with omental microvascular cells: An experimental study
    • Pasic M, Müller-Glauser W, von Segesser LK et al. Superior late patency of small diameter Dacron grafts seeded with omental microvascular cells: an experimental study. Ann Thorac Surg 1994; 58: 677-84.
    • (1994) Ann Thorac Surg , vol.58 , pp. 677-684
    • Pasic, M.1    Müller-Glauser, W.2    Von Segesser, L.K.3
  • 4
    • 0004597882 scopus 로고
    • Clinical experience with textured blood contacting surface in ventricular assist devices
    • Dasse KA, Chipman SD, Sherman CN et al. Clinical experience with textured blood contacting surface in ventricular assist devices. ASAIO J 1987; 10: 418-25.
    • (1987) ASAIO J , vol.10 , pp. 418-425
    • Dasse, K.A.1    Chipman, S.D.2    Sherman, C.N.3
  • 5
    • 37049246701 scopus 로고
    • Heparin bonding on colloidal graphite surfaces
    • Gott VL, Whiffen JD, Datton RC. Heparin bonding on colloidal graphite surfaces. Science 1963; 142: 1297-98.
    • (1963) Science , vol.142 , pp. 1297-1298
    • Gott, V.L.1    Whiffen, J.D.2    Datton, R.C.3
  • 6
    • 0021040217 scopus 로고
    • A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue
    • Larm O, Larsson R, Olsson P. A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue. Biomater Med Devices Artif Org 1983; 11: 161-73.
    • (1983) Biomater Med Devices Artif Org , vol.11 , pp. 161-173
    • Larm, O.1    Larsson, R.2    Olsson, P.3
  • 7
    • 0025456882 scopus 로고
    • Evaluation of Duraflo II heparin immobilized cardiopulmonary bypass circuits
    • Tong SD, Rolfs MR, Hsu LC. Evaluation of Duraflo II heparin immobilized cardiopulmonary bypass circuits. ASAIO J 1990; 36: 654-56.
    • (1990) ASAIO J , vol.36 , pp. 654-656
    • Tong, S.D.1    Rolfs, M.R.2    Hsu, L.C.3
  • 8
    • 0022396584 scopus 로고
    • New approaches to anticoagulation: Heparin-like biomaterials
    • Josefowicz M, Jozefonvicz J. New approaches to anticoagulation: heparin-like biomaterials. ASAIO J 1985; 8: 218-22.
    • (1985) ASAIO J , vol.8 , pp. 218-222
    • Josefowicz, M.1    Jozefonvicz, J.2
  • 9
  • 10
    • 0002517396 scopus 로고
    • Biocompatible surfaces based upon biomembrane mimicry
    • Quinn PJ, Cherry RJ eds. London: Portland Press Ltd
    • Yianni YP. Biocompatible surfaces based upon biomembrane mimicry. In: Quinn PJ, Cherry RJ eds. Structural and dynamic properties of lipids and membranes. London: Portland Press Ltd, 1992: 187-217.
    • (1992) Structural and Dynamic Properties of Lipids and Membranes , pp. 187-217
    • Yianni, Y.P.1
  • 14
    • 0026588427 scopus 로고
    • Reduction and elimination of systemic heparinization during cardiopulmonary bypass
    • von Segesser LK, Weiss BM, Garcia E et al. Reduction and elimination of systemic heparinization during cardiopulmonary bypass. J Thorac Cardiovasc Surg 1992; 103: 790-99.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 790-799
    • Von Segesser, L.K.1    Weiss, B.M.2    Garcia, E.3
  • 17
    • 0025990091 scopus 로고
    • Clinical application of heparin coated perfusion equipment with special emphasis on patients refusing homologous transfusions
    • von Segesser LK, Weiss BM, Garcia E, Turina MI. Clinical application of heparin coated perfusion equipment with special emphasis on patients refusing homologous transfusions. Perfusion 1991; 6: 227-33.
    • (1991) Perfusion , vol.6 , pp. 227-233
    • Von Segesser, L.K.1    Weiss, B.M.2    Garcia, E.3    Turina, M.I.4
  • 18
    • 0027156091 scopus 로고
    • Heparin coated circuits reduce the inflammatory response to cardiopulmonary bypass
    • Gu YJ, van Oeveren W, Akkerman C et al. Heparin coated circuits reduce the inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 1993; 55: 917-22.
    • (1993) Ann Thorac Surg , vol.55 , pp. 917-922
    • Gu, Y.J.1    Van Oeveren, W.2    Akkerman, C.3
  • 19
    • 0026538702 scopus 로고
    • Reduced complement activation with heparin coated oxygenator and tubings in coronary bypass operations
    • Videm V, Svennevig JL, Fosse E et al. Reduced complement activation with heparin coated oxygenator and tubings in coronary bypass operations. J Thorac Cardiovasc Surg 1992; 103: 806-13.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 806-813
    • Videm, V.1    Svennevig, J.L.2    Fosse, E.3
  • 20
    • 0029152890 scopus 로고
    • Heparin bonding of bypass circuits reduces cytokine release during cardiopulmonary bypass
    • Steinberg BM, Grossi EA, Schwartz DS et al. Heparin bonding of bypass circuits reduces cytokine release during cardiopulmonary bypass. Ann Thorac Surg 1995; 60: 525-29.
    • (1995) Ann Thorac Surg , vol.60 , pp. 525-529
    • Steinberg, B.M.1    Grossi, E.A.2    Schwartz, D.S.3
  • 21
    • 0028949437 scopus 로고
    • Eosinophil granule proteins in cardiopulmonary bypass with and without heparin coating
    • Nilsson L, Peterson C, Venge P et al. Eosinophil granule proteins in cardiopulmonary bypass with and without heparin coating. Ann Thorac Surg 1995; 59: 713-16.
    • (1995) Ann Thorac Surg , vol.59 , pp. 713-716
    • Nilsson, L.1    Peterson, C.2    Venge, P.3
  • 22
    • 0027530009 scopus 로고
    • Coagulation patterns in bovine left heart bypass with phospholipid versus heparin surface coating
    • von Segesser LK, Olah A, Leskosek B, Turina M. Coagulation patterns in bovine left heart bypass with phospholipid versus heparin surface coating. ASAIO J 1993; 39: 43-46.
    • (1993) ASAIO J , vol.39 , pp. 43-46
    • Von Segesser, L.K.1    Olah, A.2    Leskosek, B.3    Turina, M.4
  • 23
    • 0027741215 scopus 로고
    • Phosphatidylcholine coated chest tubes improve drainage after open heart operation
    • Hunter S, Angelini GD. Phosphatidylcholine coated chest tubes improve drainage after open heart operation. Ann Thorac Surg 1993; 56: 1339-42.
    • (1993) Ann Thorac Surg , vol.56 , pp. 1339-1342
    • Hunter, S.1    Angelini, G.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.