Volumn 19, Issue 10, 1996, Pages 1528-1529

Erosion of internal cardioverter defibrillator pocket and migration of pulse generator into the peritoneal cavity

Author keywords

ICD therapy; pulse generator migration

Indexed keywords

ADULT; ARTICLE; CARDIOVERSION; CASE REPORT; DEFIBRILLATOR; HEART ARRHYTHMIA; HEART EJECTION FRACTION; HEART VENTRICLE TACHYCARDIA; HUMAN; MALE; MIGRATION; PERITONEAL CAVITY; PULSE GENERATOR;

EID: 0029796027     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03173.x     Document Type: Article
Times cited : (4)

References (5)
  • 1
    • 0028415334 scopus 로고
    • Complications of pacemaker-defibrillator devices: Diagnosis and management
    • Pfeiffer D, Jung W, Fehske W, et al. Complications of pacemaker-defibrillator devices: Diagnosis and management. Am Heart J 1994; 127:1073-1080.
    • (1994) Am Heart J , vol.127 , pp. 1073-1080
    • Pfeiffer, D.1    Jung, W.2    Fehske, W.3
  • 2
    • 0027401339 scopus 로고
    • Complications of implantable cardioverter defibrillator therapy: Follow-up of 241 patients
    • Grim W, Flores BF, Marchlinski FE. Complications of implantable cardioverter defibrillator therapy: Follow-up of 241 patients. PACE 1993; 16(Pt. 2):218-222.
    • (1993) PACE , vol.16 , Issue.2 PART , pp. 218-222
    • Grim, W.1    Flores, B.F.2    Marchlinski, F.E.3
  • 3
    • 0025920829 scopus 로고
    • Perforation of an automatic implantable cardioverter defibrillator into the peritoneal cavity
    • Brune S, Gonska BD, Fleishmann C, et al. Perforation of an automatic implantable cardioverter defibrillator into the peritoneal cavity. Z Cardiol 1991; 80:59-61.
    • (1991) Z Cardiol , vol.80 , pp. 59-61
    • Brune, S.1    Gonska, B.D.2    Fleishmann, C.3
  • 4
    • 0025000776 scopus 로고
    • Infection in implantable cardioverter defibrillator patients
    • Wunderly D, Maloney J, Edel T, et al. Infection in implantable cardioverter defibrillator patients. PACE 1990; 13:1360-1364.
    • (1990) PACE , vol.13 , pp. 1360-1364
    • Wunderly, D.1    Maloney, J.2    Edel, T.3
  • 5
    • 0027431550 scopus 로고
    • Wound complications and treatment of the infected implantable cardioverter defibrillator generator
    • Gupta S, Prevel CD, Shaheen K, et al. Wound complications and treatment of the infected implantable cardioverter defibrillator generator. J Card Surg 1993; 8:671-677.
    • (1993) J Card Surg , vol.8 , pp. 671-677
    • Gupta, S.1    Prevel, C.D.2    Shaheen, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.