메뉴 건너뛰기




Volumn 19, Issue 10, 1996, Pages 1459-1468

The impact of pulse generator longevity on the long-term costs of cardiac pacing

Author keywords

cardiac pacing; cost of pacing; pulse generator longevity

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; COST BENEFIT ANALYSIS; COST EFFECTIVENESS ANALYSIS; DEVICE; FEMALE; FOLLOW UP; HEALTH CARE COST; HEALTH CARE SYSTEM; HEART PACING; HUMAN; MAJOR CLINICAL STUDY; MALE; PULSE GENERATOR; SURVIVAL;

EID: 0029792462     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03159.x     Document Type: Article
Times cited : (26)

References (28)
  • 1
    • 0022536810 scopus 로고
    • Single-chamber and dual-chamber cardiac pacemakers. A formal cost comparison
    • Eagle KA, Mulley AG, Singer DE, et al. Single-chamber and dual-chamber cardiac pacemakers. A formal cost comparison. Ann Intern Med 1986; 105:264-271.
    • (1986) Ann Intern Med , vol.105 , pp. 264-271
    • Eagle, K.A.1    Mulley, A.G.2    Singer, D.E.3
  • 3
    • 0024722618 scopus 로고
    • Pacemaker longevity
    • Furman S. Pacemaker longevity. PACE 1989; 12:1437-1438.
    • (1989) PACE , vol.12 , pp. 1437-1438
    • Furman, S.1
  • 4
    • 8044232563 scopus 로고
    • Adequate pulse generator selection increases cost-effectiveness in pacemaker therapy
    • Markewitz A, Kronski D, Kammeyer A, et al. Adequate pulse generator selection increases cost-effectiveness in pacemaker therapy. PACE 1993; 16(Part II):882.
    • (1993) PACE , vol.16 , Issue.2 PART , pp. 882
    • Markewitz, A.1    Kronski, D.2    Kammeyer, A.3
  • 5
    • 0027958217 scopus 로고
    • Influence of internal current and pacing current on pacemaker longevity
    • Schuchert A, Kuck K-H. Influence of internal current and pacing current on pacemaker longevity. PACE 1994; 17:13-16.
    • (1994) PACE , vol.17 , pp. 13-16
    • Schuchert, A.1    Kuck, K.-H.2
  • 6
    • 10144248213 scopus 로고
    • Engineering aspects of pulse generators for cardiac pacing
    • S Saksena, N Goldschlager (eds.): Philadelphia, WB Saunders Co.
    • Bernstein AD, Parsonnet V. Engineering aspects of pulse generators for cardiac pacing. In S Saksena, N Goldschlager (eds.): Electrical Therapy for Cardiac Arrhythmias. Philadelphia, WB Saunders Co., 1990, pp. 21-34.
    • (1990) Electrical Therapy for Cardiac Arrhythmias , pp. 21-34
    • Bernstein, A.D.1    Parsonnet, V.2
  • 7
    • 0020318569 scopus 로고
    • Symptomatic bradyarrhythmias in the adult: Natural history following pacemaker implantation
    • Simon AB, Janz N. Symptomatic bradyarrhythmias in the adult: Natural history following pacemaker implantation. PACE 1982; 5:372-383.
    • (1982) PACE , vol.5 , pp. 372-383
    • Simon, A.B.1    Janz, N.2
  • 8
    • 0022236758 scopus 로고
    • Survival and follow-up after pacemaker implantation: A comparison of patients with sick sinus syndrome, complete heart block, and atrial fibrillation
    • Alt E, Volker R, Wirtzfeld A, et al. Survival and follow-up after pacemaker implantation: A comparison of patients with sick sinus syndrome, complete heart block, and atrial fibrillation. PACE 1985; 8:849-855.
    • (1985) PACE , vol.8 , pp. 849-855
    • Alt, E.1    Volker, R.2    Wirtzfeld, A.3
  • 9
    • 0024379812 scopus 로고
    • Survival rates after pacemaker implantation: A study of patients paced for sick sinus syndrome and atrioventricular block
    • Zanini R, Facchinetti A, Gallo G, et al. Survival rates after pacemaker implantation: A study of patients paced for sick sinus syndrome and atrioventricular block. PACE 1989; 12:1065-1069.
    • (1989) PACE , vol.12 , pp. 1065-1069
    • Zanini, R.1    Facchinetti, A.2    Gallo, G.3
  • 10
    • 0026545162 scopus 로고
    • Survival in 1431 pacemaker patients: Prognostic factors and comparison with the general population
    • Jelic V, Belkic K, Djordjevic M, et al. Survival in 1431 pacemaker patients: Prognostic factors and comparison with the general population. PACE 1992; 15:141-147.
    • (1992) PACE , vol.15 , pp. 141-147
    • Jelic, V.1    Belkic, K.2    Djordjevic, M.3
  • 11
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc 1958; 53:457-481.
    • (1958) J Am Stat Assoc , vol.53 , pp. 457-481
    • Kaplan, E.L.1    Meier, P.2
  • 13
    • 10144252738 scopus 로고    scopus 로고
    • IMS America, Copyright 1993
    • IMS America, Copyright 1993.
  • 15
    • 10144238156 scopus 로고
    • Fee schedule for physicians and services for calendar year 1993
    • November 25
    • Fee schedule for physicians and services for calendar year 1993, Federal Register, November 25, 1992.
    • (1992) Federal Register
  • 16
    • 0028152957 scopus 로고
    • Report of the NASPE policy conference on antibradycardia pacemaker follow-up: Effectiveness, needs, and resources
    • Bernstein AD, Irwin ME, Parsonnet V, et al. Report of the NASPE policy conference on antibradycardia pacemaker follow-up: Effectiveness, needs, and resources. PACE 1994; 17:1714-1727.
    • (1994) PACE , vol.17 , pp. 1714-1727
    • Bernstein, A.D.1    Irwin, M.E.2    Parsonnet, V.3
  • 17
    • 10144254007 scopus 로고
    • The future of health-care delivery in America
    • Sanford C. Bernstein and Co., Inc., Copyright
    • Bernstein Research. The future of health-care delivery in America. Sanford C. Bernstein and Co., Inc., Copyright 1993.
    • (1993) Bernstein Research
  • 18
    • 0027324748 scopus 로고
    • How much will health care reform cost?
    • Angell M. How much will health care reform cost? N Engl J Med 1993; 328:1778-1779.
    • (1993) N Engl J Med , vol.328 , pp. 1778-1779
    • Angell, M.1
  • 19
    • 0027449020 scopus 로고
    • The framework of health care reform
    • Starr P. The framework of health care reform. N Engl J Med 1993; 329:1666-1672.
    • (1993) N Engl J Med , vol.329 , pp. 1666-1672
    • Starr, P.1
  • 20
    • 0027741464 scopus 로고
    • Funding for cardiac pacing and defibrillators in Calgary: The Robin Hood philosophy
    • Wyse DG, Gillis AM. Funding for cardiac pacing and defibrillators in Calgary: The Robin Hood philosophy. PACE 1993; 16:2305-2309.
    • (1993) PACE , vol.16 , pp. 2305-2309
    • Wyse, D.G.1    Gillis, A.M.2
  • 21
    • 0026475495 scopus 로고
    • Impact of the recommendations of the British Pacing and Electrophysiology Group on pacemaker prescription and on the immediate costs of pacing in the Northern Region
    • Ray SG, Griffith MJ, Jamieson S, et al. Impact of the recommendations of the British Pacing and Electrophysiology Group on pacemaker prescription and on the immediate costs of pacing in the Northern Region. Br Heart J 1992; 68:531-534.
    • (1992) Br Heart J , vol.68 , pp. 531-534
    • Ray, S.G.1    Griffith, M.J.2    Jamieson, S.3
  • 22
    • 0026758479 scopus 로고
    • Cost implications of the British Pacing and Electrophysiology Group's recommendations for pacing
    • deBelder MA, Linker NJ, Jones S, et al. Cost implications of the British Pacing and Electrophysiology Group's recommendations for pacing. Br Med J 1992; 305:861-865.
    • (1992) Br Med J , vol.305 , pp. 861-865
    • DeBelder, M.A.1    Linker, N.J.2    Jones, S.3
  • 23
    • 10144248629 scopus 로고
    • Pacemaker size reduction: What is the limit?
    • Cazeau S, Ritter P, Duconjé R, et al. Pacemaker size reduction: What is the limit? PACE 1994; 17:818.
    • (1994) PACE , vol.17 , pp. 818
    • Cazeau, S.1    Ritter, P.2    Duconjé, R.3
  • 24
    • 0027215372 scopus 로고
    • A randomized comparison of a bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: Implications for long-term programming
    • Gillis AM, Rothschild JM, Hillier K, et al. A randomized comparison of a bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: Implications for long-term programming. PACE 1993; 16:964-970.
    • (1993) PACE , vol.16 , pp. 964-970
    • Gillis, A.M.1    Rothschild, J.M.2    Hillier, K.3
  • 25
    • 0028196634 scopus 로고
    • The Bilitch Report: Performance of implantable cardiac rhythm management devices
    • Song SL. The Bilitch Report: Performance of implantable cardiac rhythm management devices. PACE 1994; 17:692-708.
    • (1994) PACE , vol.17 , pp. 692-708
    • Song, S.L.1
  • 26
    • 0026537455 scopus 로고
    • Survey of cardiac pacing in the United States in 1989
    • Bernstein AD, Parsonnet V. Survey of cardiac pacing in the United States in 1989. Am J Cardiol 1992; 64:331-338.
    • (1992) Am J Cardiol , vol.64 , pp. 331-338
    • Bernstein, A.D.1    Parsonnet, V.2
  • 27
    • 0025609846 scopus 로고
    • A new efficient nanotip lead
    • Stokes K, Bird T. A new efficient nanotip lead. PACE 1990; 13:1901-1905.
    • (1990) PACE , vol.13 , pp. 1901-1905
    • Stokes, K.1    Bird, T.2
  • 28
    • 9844265497 scopus 로고
    • Electrical characteristics of third generation steroid-eluting pacing leads: Potential for a 17-year pacemaker battery life
    • Bernsohn MM, Panzer SB, Prest-Berg K. Electrical characteristics of third generation steroid-eluting pacing leads: Potential for a 17-year pacemaker battery life. PACE 1994; 17:854.
    • (1994) PACE , vol.17 , pp. 854
    • Bernsohn, M.M.1    Panzer, S.B.2    Prest-Berg, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.