메뉴 건너뛰기




Volumn 10, Issue 5, 1996, Pages 583-585

A comparison of the endobronchial segment of modern left-sided double- lumen tubes in anesthesia for bilateral sequential lung transplantation

Author keywords

double lumen tubes; sequential bilateral lung transplantation

Indexed keywords

ANESTHESIA; ARTICLE; CONTROLLED STUDY; DOUBLE LUMEN TUBE; ENDOBRONCHIAL INTUBATION; ENDOTRACHEAL TUBE; LUNG TRANSPLANTATION; MEASUREMENT; PRIORITY JOURNAL;

EID: 0029790243     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(96)80132-7     Document Type: Article
Times cited : (8)

References (9)
  • 1
    • 0000537507 scopus 로고
    • A new flexible double-lumen catheter for bronchospirometry
    • Carlens E A new flexible double-lumen catheter for bronchospirometry J Thorac Cardiovasc Surg 18 1949 742 746
    • (1949) J Thorac Cardiovasc Surg , vol.18 , pp. 742-746
    • Carlens, E1
  • 2
    • 0023449789 scopus 로고
    • Margin of safety in positioning modern double-lumen endotracheal tubes
    • Benumof JL Partridge BL Salvatierra C Margin of safety in positioning modern double-lumen endotracheal tubes Anesthesiology 67 1987 729 738
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, JL1    Partridge, BL2    Salvatierra, C3
  • 3
    • 0024273853 scopus 로고
    • Con: Proper positioning of a double-lumen endobronchial tube can only be accomplished with the use of endoscopy
    • Brodsky JB Con: Proper positioning of a double-lumen endobronchial tube can only be accomplished with the use of endoscopy J Cardiothorac Anesth 2 1988 105 109
    • (1988) J Cardiothorac Anesth , vol.2 , pp. 105-109
    • Brodsky, JB1
  • 4
    • 7344238338 scopus 로고
    • An analysis of margin of safety in positioning double-lumen tubes
    • (poster presentation) Keating JL Benumof JL An analysis of margin of safety in positioning double-lumen tubes Anesthesiology 63 1985 A563
    • (1985) Anesthesiology , vol.63 , pp. A563
    • Keating, JL1    Benumof, JL2
  • 5
    • 0022069485 scopus 로고
    • Alteration of double-lumen endobronchial tube position by flexion and extension of the neck
    • Saito S Dohi S Hiroshi N Alteration of double-lumen endobronchial tube position by flexion and extension of the neck Anesthesiology 62 1985 696 697
    • (1985) Anesthesiology , vol.62 , pp. 696-697
    • Saito, S1    Dohi, S2    Hiroshi, N3
  • 6
    • 0016873506 scopus 로고
    • Alteration of endotracheal tube position-flexion and extension of the neck
    • Conrardy PA Goodman LR Lainge F Alteration of endotracheal tube position-flexion and extension of the neck Crit Care Med 4 1976 8 12
    • (1976) Crit Care Med , vol.4 , pp. 8-12
    • Conrardy, PA1    Goodman, LR2    Lainge, F3
  • 7
    • 0027159597 scopus 로고
    • Continuous spirometry for detection of double-lumen tube placement
    • Bardoczky GI Levarlet M Engelman E Continuous spirometry for detection of double-lumen tube placement Br J Anaesth 70 1993 499 502
    • (1993) Br J Anaesth , vol.70 , pp. 499-502
    • Bardoczky, GI1    Levarlet, M2    Engelman, E3
  • 8
    • 0027195679 scopus 로고
    • Double-lumen tubes
    • Vaughan RS Double-lumen tubes Br J Anaesth 70 5 1993 497 498
    • (1993) Br J Anaesth , vol.70 , Issue.5 , pp. 497-498
    • Vaughan, RS1
  • 9
    • 0023004111 scopus 로고
    • Placement of double-lumen endobronchial tubes
    • Smith G Hirsch N Ehrenworth J Placement of double-lumen endobronchial tubes Br J Anaesth 58 1986 1317 1320
    • (1986) Br J Anaesth , vol.58 , pp. 1317-1320
    • Smith, G1    Hirsch, N2    Ehrenworth, J3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.