메뉴 건너뛰기




Volumn 39, Issue 1, 1996, Pages 97-102

Clinical evaluation of a microsample coagulation analyzer, and comparison with existing techniques

Author keywords

anticoagulation; heparin; PTCA

Indexed keywords

ANTICOAGULATION; ARTICLE; BLOOD ANALYSIS; BLOOD CLOTTING TIME; BLOOD SAMPLING; BLOOD VOLUME; DIAGNOSTIC ACCURACY; DIAGNOSTIC PROCEDURE; HUMAN; HUMAN CELL; HUMAN TISSUE; PARTIAL THROMBOPLASTIN TIME; REPRODUCIBILITY;

EID: 0029789074     PISSN: 00986569     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0304(199609)39:1<97::AID-CCD22>3.0.CO;2-K     Document Type: Article
Times cited : (16)

References (13)
  • 1
    • 0000674404 scopus 로고
    • Abrupt vessel closure
    • Topol EJ (ed): Philadelphia: W.B. Saunders
    • Lincoff AM, Topol EJ: Abrupt vessel closure. In Topol EJ (ed): "Textbook of Interventional Cardiology." Philadelphia: W.B. Saunders, 1994, pp 207-230.
    • (1994) Textbook of Interventional Cardiology , pp. 207-230
    • Lincoff, A.M.1    Topol, E.J.2
  • 3
    • 0027193058 scopus 로고
    • Preprocedural anticoagulation does not reduce angioplasty heparin requirements
    • Blumenthal RS, Wolff MR, Resar JR, Coombs VJ, Brinker JA: Preprocedural anticoagulation does not reduce angioplasty heparin requirements. Am Heart J 125:1221-1225, 1993.
    • (1993) Am Heart J , vol.125 , pp. 1221-1225
    • Blumenthal, R.S.1    Wolff, M.R.2    Resar, J.R.3    Coombs, V.J.4    Brinker, J.A.5
  • 4
    • 0028297522 scopus 로고
    • Relation between procedural activated coagulation time and outcome after percutaneous transluminal coronary angioplasty
    • Ferguson JJ, Dougherty KG, Gaos CM, Bush HS, Marsh KC, Leachman DR: Relation between procedural activated coagulation time and outcome after percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 23:1061-1065, 1994.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 1061-1065
    • Ferguson, J.J.1    Dougherty, K.G.2    Gaos, C.M.3    Bush, H.S.4    Marsh, K.C.5    Leachman, D.R.6
  • 9
    • 0028261576 scopus 로고
    • Comparison of Hemochron and Hemotec activated coagulation time target values during percutaneous transluminal coronary angioplasty
    • Avendano A, Ferguson JJ: Comparison of Hemochron and Hemotec activated coagulation time target values during percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 23: 907-910, 1994.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 907-910
    • Avendano, A.1    Ferguson, J.J.2
  • 10
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM: Measurement in medicine: The analysis of method comparison studies. Statistician 32:307-317, 1983.
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 11
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil BJ: The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 142: 29-36, 1982.
    • (1982) Radiology , vol.142 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 12
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristics curves derived from the same cases
    • Hanley JA, McNeil BJ: A method of comparing the areas under receiver operating characteristics curves derived from the same cases. Radiology 148:839-843, 1983.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 13
    • 0028219009 scopus 로고
    • Bedside monitoring of heparin therapy: Comparison of the activated clotting time to the activated partial thromboplastin time
    • Reiner JS, Coyne KS, Lundergan CF, Ross AM: Bedside monitoring of heparin therapy: Comparison of the activated clotting time to the activated partial thromboplastin time. Cathet Cardiovasc Diagn 32:49-52, 1994.
    • (1994) Cathet Cardiovasc Diagn , vol.32 , pp. 49-52
    • Reiner, J.S.1    Coyne, K.S.2    Lundergan, C.F.3    Ross, A.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.