메뉴 건너뛰기




Volumn 11, Issue 10, 1996, Pages 1041-1049

Measurement of soluble L-lactate in dairy products using screen-printed sensors in batch mode

Author keywords

Dairy products; Lactate; Lactate oxidase; Screen printing

Indexed keywords

AMPEROMETRIC SENSORS; BIOASSAY; CALIBRATION; DAIRY PRODUCTS; ENZYME SENSORS; ENZYMES; SCREEN PRINTING; SPECTROPHOTOMETRY; STANDARDS;

EID: 0029786004     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/0956-5663(96)87663-9     Document Type: Article
Times cited : (32)

References (25)
  • 1
    • 0001441464 scopus 로고
    • A reliable L-lactate electrode with a new membrane for enzyme immobilization for amperometric assay of lactate
    • Bardeletti, G., Sechaud, F. & Coulet, P. R. (1986). A reliable L-lactate electrode with a new membrane for enzyme immobilization for amperometric assay of lactate. Anal. Chim. Acta, 187, 47-54.
    • (1986) Anal. Chim. Acta , vol.187 , pp. 47-54
    • Bardeletti, G.1    Sechaud, F.2    Coulet, P.R.3
  • 2
    • 0027649334 scopus 로고
    • Enzyme electrodes for the determination of carbohydrates in food
    • Bilitewski, U, Jager, A., Ruger, P. & Weise, W. (1993). Enzyme electrodes for the determination of carbohydrates in food. Sensors & Actuators B, 15-16, 113-118.
    • (1993) Sensors & Actuators B , vol.15-16 , pp. 113-118
    • Bilitewski, U.1    Jager, A.2    Ruger, P.3    Weise, W.4
  • 3
    • 0027474192 scopus 로고
    • Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase
    • Cardosi, M. F. & Birch, S. W. (1993). Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase. Anal. Chim. Acta, 276, 69-74.
    • (1993) Anal. Chim. Acta , vol.276 , pp. 69-74
    • Cardosi, M.F.1    Birch, S.W.2
  • 4
    • 0026709834 scopus 로고
    • Plasticized poly(vinyl chloride) as a permselective barrier membrane for high-selectivity amperometric sensors and biosensors
    • Christie, I. M., Treloar, P. H. & Vadgama, P. (1992). Plasticized poly(vinyl chloride) as a permselective barrier membrane for high-selectivity amperometric sensors and biosensors. Anal. Chim. Acta, 26, 65-73.
    • (1992) Anal. Chim. Acta , vol.26 , pp. 65-73
    • Christie, I.M.1    Treloar, P.H.2    Vadgama, P.3
  • 5
    • 0026497382 scopus 로고
    • Polymer membranes in clinical sensor applications. I. An overview of membrane function
    • Davies, M. L., Hamilton, C. J., Murphy, S. M. & Tighe, B. J. (1992). Polymer membranes in clinical sensor applications. I. An overview of membrane function. Biomaterials, 13, 971-978.
    • (1992) Biomaterials , vol.13 , pp. 971-978
    • Davies, M.L.1    Hamilton, C.J.2    Murphy, S.M.3    Tighe, B.J.4
  • 6
    • 0002659044 scopus 로고
    • Assessment of devices for in vivo monitoring of chemical species
    • Fischer, U., Alcock, S. & Turner, A. P. F. (1995). Assessment of devices for in vivo monitoring of chemical species. Biosensors & Bioelectronics, 10, xxiii-xxx.
    • (1995) Biosensors & Bioelectronics , vol.10 , pp. 23-30
    • Fischer, U.1    Alcock, S.2    Turner, A.P.F.3
  • 7
    • 0028891593 scopus 로고
    • Prototype, solid-phase, glucose biosensor
    • Gilmartin, M. A. T., Hart, J. P. & Patton, D. T. (1995), Prototype, solid-phase, glucose biosensor. Analyst, 120, 1973-1981.
    • (1995) Analyst , vol.120 , pp. 1973-1981
    • Gilmartin, M.A.T.1    Hart, J.P.2    Patton, D.T.3
  • 8
    • 0028514473 scopus 로고
    • Screen printing: A technology for the batch fabrication of integrated chemical-sensor arrays
    • Goldberg, H. D., Brown, R. B., Liu, D. P. & Meyerhoff, M. E. (1994). Screen printing: a technology for the batch fabrication of integrated chemical-sensor arrays. Sensors & Actuators B, 21, 171-183.
    • (1994) Sensors & Actuators B , vol.21 , pp. 171-183
    • Goldberg, H.D.1    Brown, R.B.2    Liu, D.P.3    Meyerhoff, M.E.4
  • 9
    • 0026029872 scopus 로고
    • Gamma-irradiation immobilization of lactate oxidase in poly(vinyl alcohol) on platinized graphite electrodes
    • Hajizadeh, K., Halsall, H. B. & Heineman, W. R. (1991a). Gamma-irradiation immobilization of lactate oxidase in poly(vinyl alcohol) on platinized graphite electrodes. Anal. Chim. Acta, 243, 23-32.
    • (1991) Anal. Chim. Acta , vol.243 , pp. 23-32
    • Hajizadeh, K.1    Halsall, H.B.2    Heineman, W.R.3
  • 10
    • 0001918854 scopus 로고
    • Immobilization of lactate oxidase in a poly(vinyl alcohol) matrix on platinized graphite electrodes by chemical cross-linking with isocyanate
    • Hajizadeh, K., Halsall, H. B. & Heineman, W. R. (1991b). Immobilization of lactate oxidase in a poly(vinyl alcohol) matrix on platinized graphite electrodes by chemical cross-linking with isocyanate. Talanta, 38, 37-47.
    • (1991) Talanta , vol.38 , pp. 37-47
    • Hajizadeh, K.1    Halsall, H.B.2    Heineman, W.R.3
  • 12
    • 0030070576 scopus 로고    scopus 로고
    • On the use of screen- and ink-jet printing to produce amperometric enzyme electrodes for lactate
    • Hart, A. L., Turner, A. P. F. & Hopcroft, D. (1996). On the use of screen-and ink-jet printing to produce amperometric enzyme electrodes for lactate. Biosensors & Bioelectronics, 11, 263-270.
    • (1996) Biosensors & Bioelectronics , vol.11 , pp. 263-270
    • Hart, A.L.1    Turner, A.P.F.2    Hopcroft, D.3
  • 13
    • 0000831018 scopus 로고
    • L-(+)-lactate determination with lactate dehydrogenase and NAD
    • H. U. Bergmeyer (ed.), Academic Press, New York
    • Ingeborg, G. & Wahlefeld, A. W. (1963). L-(+)-lactate determination with lactate dehydrogenase and NAD. In: Methods of Enzymatic Analysis, H. U. Bergmeyer (ed.), Academic Press, New York, Vol. 3, pp. 1464-1468.
    • (1963) Methods of Enzymatic Analysis , vol.3 , pp. 1464-1468
    • Ingeborg, G.1    Wahlefeld, A.W.2
  • 14
    • 0024678426 scopus 로고
    • The development of an amperometric microbial biosensor using Acetobacter pasteurianus for lactic acid
    • Luong, J. H. T., Mulchandani, A. & Groom, C. A. (1989). The development of an amperometric microbial biosensor using Acetobacter pasteurianus for lactic acid. J. Biotechnol., 10, 241-252.
    • (1989) J. Biotechnol. , vol.10 , pp. 241-252
    • Luong, J.H.T.1    Mulchandani, A.2    Groom, C.A.3
  • 15
    • 0024941085 scopus 로고
    • Design and applications of enzyme electrode probes
    • Mascini, M. & Palleschi, G. (1989). Design and applications of enzyme electrode probes. Selective Electrode Rev., 11, 191-264.
    • (1989) Selective Electrode Rev. , vol.11 , pp. 191-264
    • Mascini, M.1    Palleschi, G.2
  • 16
    • 0029163952 scopus 로고
    • Tetrathiafulvalene-mediated biosensor for L-lactate in dairy products
    • Mulchandani, A., Bassi, A. S. & Nguyen, A. (1995). Tetrathiafulvalene-mediated biosensor for L-lactate in dairy products. J. Food Sci., 60, 74-78.
    • (1995) J. Food Sci. , vol.60 , pp. 74-78
    • Mulchandani, A.1    Bassi, A.S.2    Nguyen, A.3
  • 17
    • 0026445464 scopus 로고
    • Polymer membranes in clinical sensor applications. II. The design and fabrication of permselective hydrogels for electrochemical devices
    • Murphy, S. M., Hamilton, C. J., Davies, M. L. & Tighe, B. J. (1992). Polymer membranes in clinical sensor applications. II. The design and fabrication of permselective hydrogels for electrochemical devices. Biomaterials, 13, 979-990.
    • (1992) Biomaterials , vol.13 , pp. 979-990
    • Murphy, S.M.1    Hamilton, C.J.2    Davies, M.L.3    Tighe, B.J.4
  • 18
    • 85030271573 scopus 로고
    • Thick-film multi-layer pH sensor for biomedical applications
    • Bordeaux
    • Pace, S. J. & Jensen, M. A. (1986). Thick-film multi-layer pH sensor for biomedical applications. Proc. 2nd Int. Meeting on Chemical Sensors, Bordeaux, pp. 6-13.
    • (1986) Proc. 2nd Int. Meeting on Chemical Sensors , pp. 6-13
    • Pace, S.J.1    Jensen, M.A.2
  • 20
    • 0025163721 scopus 로고
    • Amperometric tetrathiafulvalene-mediated lactate electrode using lactate oxidase absorbed on carbon foil
    • Palleschi, G. & Turner, A. P. F. (1990). Amperometric tetrathiafulvalene-mediated lactate electrode using lactate oxidase absorbed on carbon foil. Anal. Chim. Acta, 234, 459-463.
    • (1990) Anal. Chim. Acta , vol.234 , pp. 459-463
    • Palleschi, G.1    Turner, A.P.F.2
  • 21
    • 0028090182 scopus 로고
    • An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: Determination of lactate in serum by flow injection analysis
    • Palmisano, F., Centonze, D. & Zambonin, P. G. (1994). An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: determination of lactate in serum by flow injection analysis. Biosensors & Bioelectronics, 9, 471-479.
    • (1994) Biosensors & Bioelectronics , vol.9 , pp. 471-479
    • Palmisano, F.1    Centonze, D.2    Zambonin, P.G.3
  • 23
    • 0028922823 scopus 로고
    • Engineering the right membranes for electrodes at the biological interface; solvent cast and electropolymerized
    • Treloar, P. H., Christie, I. M. & Vagdama, P. M. (1995). Engineering the right membranes for electrodes at the biological interface; solvent cast and electropolymerized. Biosensors & Bioelectronics, 10, 195-201.
    • (1995) Biosensors & Bioelectronics , vol.10 , pp. 195-201
    • Treloar, P.H.1    Christie, I.M.2    Vagdama, P.M.3
  • 25
    • 0000890320 scopus 로고
    • Unmediated amperometric enzyme electrodes
    • A. E. G. Cass (ed.). IRL Press, Oxford
    • Wilson, G. S. & Thevenot, D. R. (1990). Unmediated amperometric enzyme electrodes. In: Biosensors, A Practical Approach, A. E. G. Cass (ed.). IRL Press, Oxford, pp. 1-17.
    • (1990) Biosensors, A Practical Approach , pp. 1-17
    • Wilson, G.S.1    Thevenot, D.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.