Volumn 132, Issue 2 I, 1996, Pages 376-381

Volume-rendered, three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: Validation in an in vitro model

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTICLE; ECHOCARDIOGRAPHY; HEART ATRIUM SEPTUM DEFECT; IN VITRO STUDY; NONHUMAN; PRIORITY JOURNAL; SWINE; THREE DIMENSIONAL IMAGING;

EID: 0029780660     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-8703(96)90436-6     Document Type: Article
Times cited : (46)

References (28)
  • 1
    • 0025797609 scopus 로고
    • Relationship of echocardiographic, shunt flow and angiographic size to the stretched diameter of the atrial septal defect
    • PS Rao R Langhough Relationship of echocardiographic, shunt flow and angiographic size to the stretched diameter of the atrial septal defect Am Heart J 122 1991 505 508
    • (1991) Am Heart J , vol.122 , pp. 505-508
    • Rao, PS1    Langhough, R2
  • 2
    • 0026212439 scopus 로고
    • Color Doppler echocardiographic assessment of atrial septal defect size: correlation with surgical measurements
    • F Faletra S Scarpini A Moreo GR Ciliberto P Austoni F Donatelli Color Doppler echocardiographic assessment of atrial septal defect size: correlation with surgical measurements J Am Soc Echocardiogr 4 1991 429 434
    • (1991) J Am Soc Echocardiogr , vol.4 , pp. 429-434
    • Faletra, F1    Scarpini, S2    Moreo, A3    Ciliberto, GR4    Austoni, P5    Donatelli, F6
  • 3
    • 0026750429 scopus 로고
    • Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for trancatheter occlusion
    • PS Rao R Langhough RH Beekmann TR Lloyd EB Sideris Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for trancatheter occlusion Am Heart J 124 1992 172 175
    • (1992) Am Heart J , vol.124 , pp. 172-175
    • Rao, PS1    Langhough, R2    Beekmann, RH3    Lloyd, TR4    Sideris, EB5
  • 4
    • 0025276752 scopus 로고
    • Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect
    • WE Hellenbrand JT Fahey FX McGowan GG Weltin CS Kleinman Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect Am J Cardiol 66 1990 207 213
    • (1990) Am J Cardiol , vol.66 , pp. 207-213
    • Hellenbrand, WE1    Fahey, JT2    McGowan, FX3    Weltin, GG4    Kleinman, CS5
  • 5
    • 0027284977 scopus 로고
    • Biplane transesophageal echo-Doppler studies of atrial septal defects: quantitative evaluation and monitoring for transcatheter closure
    • M Ishii H Kato O Inoue J Takagi Y Maeno T Sugimura Biplane transesophageal echo-Doppler studies of atrial septal defects: quantitative evaluation and monitoring for transcatheter closure Am Heart J 125 1993 1363 1368
    • (1993) Am Heart J , vol.125 , pp. 1363-1368
    • Ishii, M1    Kato, H2    Inoue, O3    Takagi, J4    Maeno, Y5    Sugimura, T6
  • 6
    • 0028861652 scopus 로고
    • Echocardiographic predictors of success of catheter closure of atrial septal defect with buttoned device
    • SCB Reddy PS Rao J Ewenko R Kosicik AD Wilson Echocardiographic predictors of success of catheter closure of atrial septal defect with buttoned device Am Heart J 129 1995 76 82
    • (1995) Am Heart J , vol.129 , pp. 76-82
    • Reddy, SCB1    Rao, PS2    Ewenko, J3    Kosicik, R4    Wilson, AD5
  • 8
    • 0027494271 scopus 로고
    • Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter
    • F Godart C Rey C Francart M Jarrar G Vaksmann Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter Am J Cardiol 72 1993 1095 1097
    • (1993) Am J Cardiol , vol.72 , pp. 1095-1097
    • Godart, F1    Rey, C2    Francart, C3    Jarrar, M4    Vaksmann, G5
  • 9
    • 0026466948 scopus 로고
    • Three-dimensional and four-dimensional transesophageal echocardiographic imaging of the heart and aorta in humans using a computed tomographic probe
    • NG Pandian NC Nanda SL Schwartz P Fan QL Cao R Sanyal Three-dimensional and four-dimensional transesophageal echocardiographic imaging of the heart and aorta in humans using a computed tomographic probe Echocardiography 9 1992 677 687
    • (1992) Echocardiography , vol.9 , pp. 677-687
    • Pandian, NG1    Nanda, NC2    Schwartz, SL3    Fan, P4    Cao, QL5    Sanyal, R6
  • 10
    • 0027526385 scopus 로고
    • Three- and four-dimensional cardiovascular ultrasound imaging: a new era for echocardiography
    • M Belohlavek DA Foley TC Gerber TM Kinter JF Greenleaf JB Seward Three- and four-dimensional cardiovascular ultrasound imaging: a new era for echocardiography Mayo Clin Proc 68 1993 221 240
    • (1993) Mayo Clin Proc , vol.68 , pp. 221-240
    • Belohlavek, M1    Foley, DA2    Gerber, TC3    Kinter, TM4    Greenleaf, JF5    Seward, JB6
  • 11
    • 0028268604 scopus 로고
    • Simulation of intraoperative visualization of cardiac structure and study of dynamic surgical anatomy with real-time three-dimensional echocardiography in patients
    • SL Schwartz QL Cao J Azevedo NG Pandian Simulation of intraoperative visualization of cardiac structure and study of dynamic surgical anatomy with real-time three-dimensional echocardiography in patients Am J Cardiol 73 1994 501 507
    • (1994) Am J Cardiol , vol.73 , pp. 501-507
    • Schwartz, SL1    Cao, QL2    Azevedo, J3    Pandian, NG4
  • 12
    • 0027376658 scopus 로고
    • Three-dimensional ultrasound of the atrial septum: normal and pathologic anatomy
    • M Belohlavek DA Foley TC Gerber JF Greenleef JB Seward Three-dimensional ultrasound of the atrial septum: normal and pathologic anatomy J Am Coll Cardiol 22 1993 1673 1678
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1673-1678
    • Belohlavek, M1    Foley, DA2    Gerber, TC3    Greenleef, JF4    Seward, JB5
  • 13
    • 0028814182 scopus 로고
    • Delineation of site, relative size and dynamic geometry of atrial septal defect by real-time three-dimensional echocardiography
    • GR Marx DR Fulton NG Pandian M Vogel QL Cao A Ludomirsky Delineation of site, relative size and dynamic geometry of atrial septal defect by real-time three-dimensional echocardiography J Am Coll Cardiol 25 1995 482 490
    • (1995) J Am Coll Cardiol , vol.25 , pp. 482-490
    • Marx, GR1    Fulton, DR2    Pandian, NG3    Vogel, M4    Cao, QL5    Ludomirsky, A6
  • 14
    • 0028113558 scopus 로고
    • Enhanced comprehension of dynamic cardiovascular anatomy by three-dimensional echocardiography with the use of mixed shading technique
    • QL Cao NG Pandian J Azevedo SL Schwartz M Vogel D Fulton Enhanced comprehension of dynamic cardiovascular anatomy by three-dimensional echocardiography with the use of mixed shading technique Echocardiography 11 1994 627 633
    • (1994) Echocardiography , vol.11 , pp. 627-633
    • Cao, QL1    Pandian, NG2    Azevedo, J3    Schwartz, SL4    Vogel, M5    Fulton, D6
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurements
    • JM Bland DG Altman Statistical methods for assessing agreement between two methods of clinical measurements Lancet 1 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, JM1    Altman, DG2
  • 16
    • 0017300623 scopus 로고
    • Secundum atrial septal defects: nonoperative closure during cardiac catheterization
    • TD King NL Mills Secundum atrial septal defects: nonoperative closure during cardiac catheterization JAMA 235 1976 2506 2509
    • (1976) JAMA , vol.235 , pp. 2506-2509
    • King, TD1    Mills, NL2
  • 17
    • 0024554238 scopus 로고
    • Transcatheter closure of atrial septal defect: experimental studies
    • JE Lock JJ Rome R Davis SV Praagh SB Perry RV Praagh Transcatheter closure of atrial septal defect: experimental studies Circulation 79 1989 1091 1099
    • (1989) Circulation , vol.79 , pp. 1091-1099
    • Lock, JE1    Rome, JJ2    Davis, R3    Praagh, SV4    Perry, SB5    Praagh, RV6
  • 18
    • 0024991050 scopus 로고
    • Double umbrella closure of atrial defect
    • JJ Rome JF Keane SB Perry PJ Spevak JE Lock Double umbrella closure of atrial defect Initial clinical applications 3rd ed. Circulation 82 1990 751 758
    • (1990) , pp. 751-758
    • Rome, JJ1    Keane, JF2    Perry, SB3    Spevak, PJ4    Lock, JE5
  • 20
    • 0028008388 scopus 로고
    • Atrial septal defect occlusion with the buttoned device (a multi-institutional US trial)
    • TR Loyd PS Rao RH Beekman AM Mendelsohn EB Sideris Atrial septal defect occlusion with the buttoned device (a multi-institutional US trial) Am J Cardiol 73 1994 286 291
    • (1994) Am J Cardiol , vol.73 , pp. 286-291
    • Loyd, TR1    Rao, PS2    Beekman, RH3    Mendelsohn, AM4    Sideris, EB5
  • 21
    • 0027515761 scopus 로고
    • Experimental atrial septal defect closure with a new, transcatheter, self-centering device
    • GS Das G Voss G Jarvis K Wyche R Gunther RF Wilson Experimental atrial septal defect closure with a new, transcatheter, self-centering device Circulation 88 1993 1754 1764 (part 1)
    • (1993) Circulation , vol.88 , pp. 1754-1764
    • Das, GS1    Voss, G2    Jarvis, G3    Wyche, K4    Gunther, R5    Wilson, RF6
  • 22
    • 0017863110 scopus 로고
    • Measurements of atrial septal defect during cardiac catheterization
    • TD King SL Thompson NL Mills Measurements of atrial septal defect during cardiac catheterization Experimental and clinical results 3rd ed. Am J Cardiol 41 1978 537 542
    • (1978) , pp. 537-542
    • King, TD1    Thompson, SL2    Mills, NL3
  • 23
    • 0026530603 scopus 로고
    • Role of “buttoned” double-disk device in the management of atrial septal defects
    • PS Rao AD Wilson JM Levy VK Gupta PS Chopra Role of “buttoned” double-disk device in the management of atrial septal defects Am Heart J 123 1992 191 200
    • (1992) Am Heart J , vol.123 , pp. 191-200
    • Rao, PS1    Wilson, AD2    Levy, JM3    Gupta, VK4    Chopra, PS5
  • 24
    • 0008274818 scopus 로고
    • Patient selection for transcatheter occlusion of atrial septal defect: 2-D echocardiographic criteria
    • AK Cabalka Ludomirski MP O'Laughlin CE Mullins Patient selection for transcatheter occlusion of atrial septal defect: 2-D echocardiographic criteria Circulation 82 suppl III 1990 402
    • (1990) Circulation , vol.82 , Issue.suppl III , pp. 402
    • Cabalka, AK1    Ludomirski2    O'Laughlin, MP3    Mullins, CE4
  • 25
    • 0027452713 scopus 로고
    • Intracardiac echocardiography in humans using a small-sized (6F), low-frequency (12.5 MHz) ultrasound catheter: methods, imaging planes and clinical experience
    • SL Schwartz LD Gillam AR Weintraub BW Sanzobrino JA Hirst T Hsu Intracardiac echocardiography in humans using a small-sized (6F), low-frequency (12.5 MHz) ultrasound catheter: methods, imaging planes and clinical experience J Am Coll Cardiol 21 1993 189 198
    • (1993) J Am Coll Cardiol , vol.21 , pp. 189-198
    • Schwartz, SL1    Gillam, LD2    Weintraub, AR3    Sanzobrino, BW4    Hirst, JA5    Hsu, T6
  • 26
    • 0029143038 scopus 로고
    • Intracardiac ultrasonographic assessment of atrial septal defect area: in vitro validation and technical considerations
    • JA Vazquez de Prada L Jiang MH Chen LR Padial JL Guerrero E Schwammenthal Intracardiac ultrasonographic assessment of atrial septal defect area: in vitro validation and technical considerations Am Heart J 130 1995 302 306
    • (1995) Am Heart J , vol.130 , pp. 302-306
    • Vazquez de Prada, JA1    Jiang, L2    Chen, MH3    Padial, LR4    Guerrero, JL5    Schwammenthal, E6
  • 27
    • 1842382943 scopus 로고
    • Quantitative three-dimensional echocardiographic evaluation of the size and geometry of ventricular septal defect
    • QL Cao A Delabays L Sugeng M Krauss A Ludomirski N Pandian Quantitative three-dimensional echocardiographic evaluation of the size and geometry of ventricular septal defect Circulation 90 1994 I 530
    • (1994) Circulation , vol.90 , pp. I-530
    • Cao, QL1    Delabays, A2    Sugeng, L3    Krauss, M4    Ludomirski, A5    Pandian, N6
  • 28
    • 0343886217 scopus 로고
    • Evaluation of the accuracy of new quantitative image processing method in measuring the size of ventricular septal defect directly on three-dimensional echocardiograms and factors influencing its reliability
    • L Sugeng QL Cao A Delabays G Magni G Marx A Ludomirski Evaluation of the accuracy of new quantitative image processing method in measuring the size of ventricular septal defect directly on three-dimensional echocardiograms and factors influencing its reliability [abstract] J Am Coll Cardiol 25 1995 185A (suppl)
    • (1995) J Am Coll Cardiol , vol.25 , pp. 185A
    • Sugeng, L1    Cao, QL2    Delabays, A3    Magni, G4    Marx, G5    Ludomirski, A6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.