메뉴 건너뛰기




Volumn 94, Issue 7, 1996, Pages 1545-1552

Determination of angiographic (TIMI grade) blood flow by intracoronary Doppler flow velocity during acute myocardial infarction

Author keywords

angioplasty; hemodynamics; myocardial infarction; regional blood flow; reperfusion

Indexed keywords

ACUTE HEART INFARCTION; ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; BLOOD FLOW VELOCITY; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; DOPPLER FLOWMETRY; FEMALE; HUMAN; MALE; PRIORITY JOURNAL; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 0029778750     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.94.7.1545     Document Type: Article
Times cited : (124)

References (28)
  • 1
    • 0000378172 scopus 로고
    • The Thrombolysis in Myocardial Infarction (TIMI) trial: Phase I findings
    • The TIMI Study Group. The Thrombolysis in Myocardial Infarction (TIMI) trial: phase I findings. N Engl J Med. 1984;33:523-530.
    • (1984) N Engl J Med , vol.33 , pp. 523-530
  • 2
    • 0024514359 scopus 로고
    • Comparison of invasive and conservative strategies after treatment with intravenous tissue plasminogen activator in acute myocardial infarction: Results of the Thrombolysis in Myocardial Infarction (TIMI) phase II trial
    • The TIMI Study Group. Comparison of invasive and conservative strategies after treatment with intravenous tissue plasminogen activator in acute myocardial infarction: results of the Thrombolysis in Myocardial Infarction (TIMI) phase II trial. N Engl J Med. 1989;320:618-627.
    • (1989) N Engl J Med , vol.320 , pp. 618-627
  • 3
    • 0027240597 scopus 로고
    • An international randomized trial comparing four thrombolytic strategies for acute myocardial infarction
    • The GUSTO Investigators. An international randomized trial comparing four thrombolytic strategies for acute myocardial infarction. N Engl J Med. 1993;329:673-682.
    • (1993) N Engl J Med , vol.329 , pp. 673-682
  • 4
    • 0027424433 scopus 로고
    • The effects of tissue plasminogen activator, streptokinase, or both on coronary artery patency, ventricular function, and survival after acute myocardial infarction
    • The GUSTO Angiographic Investigators. The effects of tissue plasminogen activator, streptokinase, or both on coronary artery patency, ventricular function, and survival after acute myocardial infarction. N Engl J Med. 1993;329:1615-1622.
    • (1993) N Engl J Med , vol.329 , pp. 1615-1622
  • 5
    • 0024380783 scopus 로고
    • Discrepancies between the effects of coronary reperfusion on survival and left ventricular function
    • Van Der Werf F. Discrepancies between the effects of coronary reperfusion on survival and left ventricular function. Lancet. 1989;1:1367-1369.
    • (1989) Lancet , vol.1 , pp. 1367-1369
    • Van Der Werf, F.1
  • 6
    • 0027245839 scopus 로고
    • Impact of early perfusion status of the infarct-related artery on short-term mortality after thrombolysis for acute myocardial infarction: Retrospective analysis of four German multicenter studies
    • Vogt A, von Essen R, Tebbe U, Feuerer W, Appel KF, Neuhaus KL. Impact of early perfusion status of the infarct-related artery on short-term mortality after thrombolysis for acute myocardial infarction: retrospective analysis of four German multicenter studies. J Am Coll Cardiol 1993 ;21:1391-1395.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1391-1395
    • Vogt, A.1    Von Essen, R.2    Tebbe, U.3    Feuerer, W.4    Appel, K.F.5    Neuhaus, K.L.6
  • 7
    • 0027172657 scopus 로고
    • TIMI perfusion grade 3 but not grade 2 results in improved outcome after thrombolysis for myocardial infarction: Ventriculographic, enzymatic, and electrocardiographic evidence from the TEAM-3 study
    • for the TEAM-3 Investigators.
    • Anderson JL, Karagounis LA, Becker LC, Sorensen SG, Menlove RL, for the TEAM-3 Investigators. TIMI perfusion grade 3 but not grade 2 results in improved outcome after thrombolysis for myocardial infarction: ventriculographic, enzymatic, and electrocardiographic evidence from the TEAM-3 study. Circulation. 1993;87:1829-1839.
    • (1993) Circulation , vol.87 , pp. 1829-1839
    • Anderson, J.L.1    Karagounis, L.A.2    Becker, L.C.3    Sorensen, S.G.4    Menlove, R.L.5
  • 9
    • 0026569906 scopus 로고
    • Does Thrombolysis in Myocardial Infarction (TIMI) perfusion grade 2 represent a mostly patent artery or a mostly occluded artery? Enzymatic and electrocardiographic evidence from the TEAM-2 study
    • for the TEAM-2 Investigators.
    • Karagounis L, Sorensen SG, Menlove RL, Moreno F, Anderson JL, for the TEAM-2 Investigators. Does Thrombolysis in Myocardial Infarction (TIMI) perfusion grade 2 represent a mostly patent artery or a mostly occluded artery? Enzymatic and electrocardiographic evidence from the TEAM-2 study. J Am Coll Cardiol. 1992;19:1-10.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1-10
    • Karagounis, L.1    Sorensen, S.G.2    Menlove, R.L.3    Moreno, F.4    Anderson, J.L.5
  • 10
    • 0023185453 scopus 로고
    • Quantitative measurement of coronary flow during medical revascularization (thrombolysis or angioplasty) in patients with acute infarction
    • Nicklas JM, Diltz EA, O'Neill WW, Bourdillon PDV, Walton JA Jr, Pitt B. Quantitative measurement of coronary flow during medical revascularization (thrombolysis or angioplasty) in patients with acute infarction. J Am Coll Cardiol. 1987;10:284-289.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 284-289
    • Nicklas, J.M.1    Diltz, E.A.2    O'Neill, W.W.3    Bourdillon, P.D.V.4    Walton Jr., J.A.5    Pitt, B.6
  • 11
    • 0027176964 scopus 로고
    • Impaired coronary flow reserve immediately after coronary angioplasty in patients with acute myocardial infarction
    • Ishihara M, Sato H, Tateishi H, Kawagoe T, Yoshimura M, Muraoka Y. Impaired coronary flow reserve immediately after coronary angioplasty in patients with acute myocardial infarction. Br Heart J. 1993;69:288-292.
    • (1993) Br Heart J , vol.69 , pp. 288-292
    • Ishihara, M.1    Sato, H.2    Tateishi, H.3    Kawagoe, T.4    Yoshimura, M.5    Muraoka, Y.6
  • 12
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM, Flynn AE, Goto M, Nassi M, Segal J. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation. 1992;85:1899-1911.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3    Flynn, A.E.4    Goto, M.5    Nassi, M.6    Segal, J.7
  • 15
    • 0021923120 scopus 로고
    • Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects
    • Rentrop KP, Cohen M, Blanke H, Phillips RA. Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects. J Am Coll Cardiol. 1985;5:587-592.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 587-592
    • Rentrop, K.P.1    Cohen, M.2    Blanke, H.3    Phillips, R.A.4
  • 19
    • 0027477325 scopus 로고
    • Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty
    • Ofili EO, Kern MJ, Labovitz AJ, St. Vrain JA, Segal J, Aguirre F, Castello R. Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty. J Am Coll Cardiol. 1993;21:308-316.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 308-316
    • Ofili, E.O.1    Kern, M.J.2    Labovitz, A.J.3    St. Vrain, J.A.4    Segal, J.5    Aguirre, F.6    Castello, R.7
  • 21
    • 0022613448 scopus 로고
    • Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve
    • Nissen SE, Eliot JL, Booth DC. Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve. Circulation. 1986:73:562-571.
    • (1986) Circulation , vol.73 , pp. 562-571
    • Nissen, S.E.1    Eliot, J.L.2    Booth, D.C.3
  • 22
    • 0027299011 scopus 로고
    • Variability of coronary flow reserve assessed by Doppler catheter after successful thrombolysis in patients with acute myocardial infarction
    • Crea F, Graham D, Crake T, Gaspardone A, Galassi A, Kaski JC, Maseri A. Variability of coronary flow reserve assessed by Doppler catheter after successful thrombolysis in patients with acute myocardial infarction. Am Heart J. 1993;125:1547-1552.
    • (1993) Am Heart J , vol.125 , pp. 1547-1552
    • Crea, F.1    Graham, D.2    Crake, T.3    Gaspardone, A.4    Galassi, A.5    Kaski, J.C.6    Maseri, A.7
  • 23
    • 0028226363 scopus 로고
    • Predictive value of reactive hyperemic response on reperfusion on recovery of regional myocardial function after coronary angioplasty in acute myocardial infarction
    • Suryapranata H, Zijlstra F, MacLeod DC, van den Brand M, de Feyter PJ, Serruys PW. Predictive value of reactive hyperemic response on reperfusion on recovery of regional myocardial function after coronary angioplasty in acute myocardial infarction. Circulation, 1994;89:1109-1117.
    • (1994) Circulation , vol.89 , pp. 1109-1117
    • Suryapranata, H.1    Zijlstra, F.2    MacLeod, D.C.3    Van Den Brand, M.4    De Feyter, P.J.5    Serruys, P.W.6
  • 24
    • 0028914981 scopus 로고
    • Link between the angiographic substudy and mortality outcomes in a large randomized trial of myocardial reperfusion: Importance of early and complete infarct artery reperfusion
    • for the GUSTO-I Investigators.
    • Simes RJ, Topol EJ, Holmes DR Jr. White HD, Rutsch WR, Vahanian A, Simoons ML, Morn's D, Betriu A, Califf RM, Ross AM, for the GUSTO-I Investigators. Link between the angiographic substudy and mortality outcomes in a large randomized trial of myocardial reperfusion: importance of early and complete infarct artery reperfusion. Circulation. 1995;91:1923-1928.
    • (1995) Circulation , vol.91 , pp. 1923-1928
    • Simes, R.J.1    Topol, E.J.2    Holmes Jr., D.R.3    White, H.D.4    Rutsch, W.R.5    Vahanian, A.6    Simoons, M.L.7    MorN'S, D.8    Betriu, A.9    Califf, R.M.10    Ross, A.M.11
  • 25
    • 0016698772 scopus 로고
    • Reduced myocardial reflow and increased coronary vascular resistance following prolonged myocardial ischemia in the dog
    • Willerson JT, Watson JT, Hutton I, Templeton GH, Fixler DE. Reduced myocardial reflow and increased coronary vascular resistance following prolonged myocardial ischemia in the dog. Circ Res. 1975:36:771-781.
    • (1975) Circ Res , vol.36 , pp. 771-781
    • Willerson, J.T.1    Watson, J.T.2    Hutton, I.3    Templeton, G.H.4    Fixler, D.E.5
  • 27
    • 0028308220 scopus 로고
    • Adenosine protects against attenuation of flow reserve and myocardial function after coronary occlusion and reperfusion
    • Nichols WW, Nicolini FA, Yang BC, Henson K, Stechmiller JK, Mehta JL. Adenosine protects against attenuation of flow reserve and myocardial function after coronary occlusion and reperfusion. Am Heart J. 1994;127:1201-1211.
    • (1994) Am Heart J , vol.127 , pp. 1201-1211
    • Nichols, W.W.1    Nicolini, F.A.2    Yang, B.C.3    Henson, K.4    Stechmiller, J.K.5    Mehta, J.L.6
  • 28
    • 0027392824 scopus 로고
    • Augmentation of coronary blood flow by intra-aortic balloon pumping in patients after coronary angioplasty
    • Kern MJ, Aguirre F, Bach R, Donohue T, Segal J. Augmentation of coronary blood flow by intra-aortic balloon pumping in patients after coronary angioplasty. Circulation. 1993;87;500-511.
    • (1993) Circulation , vol.87 , pp. 500-511
    • Kern, M.J.1    Aguirre, F.2    Bach, R.3    Donohue, T.4    Segal, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.