메뉴 건너뛰기




Volumn 42, Issue 9, 1996, Pages 1405-1411

Determination of serum and urinary aluminum by HPLC with fluorometric detection of Al-lumogallion complex

Author keywords

inter method comparison; occupational exposure; toxicology

Indexed keywords

ALUMINUM;

EID: 0029776054     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/42.9.1405     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 0026632279 scopus 로고
    • Toxicity of aluminum: A historical review
    • Winship KA. Toxicity of aluminum: a historical review, part 1. Adverse Drug React Toxicol Rev 1992;11:123-41.
    • (1992) Adverse Drug React Toxicol Rev , vol.11 , Issue.1 PART , pp. 123-141
    • Winship, K.A.1
  • 2
    • 0027292713 scopus 로고
    • Toxicity of aluminum: A historical review
    • Winship KA. Toxicity of aluminum: a historical review, part 2. Adverse Drug React Toxicol Rev 1993;12:177-211.
    • (1993) Adverse Drug React Toxicol Rev , vol.12 , Issue.2 PART , pp. 177-211
    • Winship, K.A.1
  • 5
    • 9544229968 scopus 로고
    • Blood and urine concentration of aluminum among workers exposed to aluminum flake powders
    • Ljunggren KG, Lidums V, Sjoren B. Blood and urine concentration of aluminum among workers exposed to aluminum flake powders. Br J Ind Med 1991;15:66-70.
    • (1991) Br J Ind Med , vol.15 , pp. 66-70
    • Ljunggren, K.G.1    Lidums, V.2    Sjoren, B.3
  • 7
    • 0028569467 scopus 로고
    • The biological speciation and toxicokinetics of aluminum
    • DeVoto E, Yokel RA. The biological speciation and toxicokinetics of aluminum [Review]. Environ Health Perspect 1994;102:940-51.
    • (1994) Environ Health Perspect , vol.102 , pp. 940-951
    • Devoto, E.1    Yokel, R.A.2
  • 8
    • 0021796116 scopus 로고
    • Measurement of aluminum in serum, blood, urine and tissues of chronic hemodialyzed patient by use of electrothermal atomic absorption spectrometry
    • D'Haese PC, van der Vyver FL, de Wolff FA, De Broe ME. Measurement of aluminum in serum, blood, urine and tissues of chronic hemodialyzed patient by use of electrothermal atomic absorption spectrometry. Clin Chem 1985;31:24-9.
    • (1985) Clin Chem , vol.31 , pp. 24-29
    • D'Haese, P.C.1    Van Der Vyver, F.L.2    De Wolff, F.A.3    De Broe, M.E.4
  • 9
    • 37049069053 scopus 로고
    • An overview of recent developments in the determination of aluminum in serum by furnace atomic absorption spectrometry
    • Slavin W. An overview of recent developments in the determination of aluminum in serum by furnace atomic absorption spectrometry. J Anal At Spectrom 1986;1:281-5.
    • (1986) J Anal at Spectrom , vol.1 , pp. 281-285
    • Slavin, W.1
  • 10
    • 0024473024 scopus 로고
    • Electrothermal atomic absorption spectrometric determination of aluminum: Elimination of serum matrix effects
    • Gitelman HJ, Alderman FR. Electrothermal atomic absorption spectrometric determination of aluminum: elimination of serum matrix effects. Clin Chem 1989;35:1517-9.
    • (1989) Clin Chem , vol.35 , pp. 1517-1519
    • Gitelman, H.J.1    Alderman, F.R.2
  • 11
    • 0026063933 scopus 로고
    • Aluminum levels in normal human serum and urine as determined by Zeeman atomic absorption spectrometry
    • Wang ST, Pizzolato S, Demshar HP. Aluminum levels in normal human serum and urine as determined by Zeeman atomic absorption spectrometry. J Anal Toxicol 1991;15:66-70.
    • (1991) J Anal Toxicol , vol.15 , pp. 66-70
    • Wang, S.T.1    Pizzolato, S.2    Demshar, H.P.3
  • 12
    • 0020511912 scopus 로고
    • Excretion and retention of low or moderate levels of aluminum by human subjects
    • Greger JL, Baier MJ. Excretion and retention of low or moderate levels of aluminum by human subjects. Food Chem Toxicol 1983;21:473-7.
    • (1983) Food Chem Toxicol , vol.21 , pp. 473-477
    • Greger, J.L.1    Baier, M.J.2
  • 13
    • 0029345070 scopus 로고
    • Aqueous AI (III) speciation by high-performance cation-exchange chromatography with fluorescence detection of the aluminum-lumogallion complex
    • Sutheimer SH, Cabaniss SE. Aqueous AI (III) speciation by high-performance cation-exchange chromatography with fluorescence detection of the aluminum-lumogallion complex. Anal Chem 1995;67:2342-9.
    • (1995) Anal Chem , vol.67 , pp. 2342-2349
    • Sutheimer, S.H.1    Cabaniss, S.E.2
  • 14
    • 0028955560 scopus 로고
    • Determination of serum aluminum using an ion-pair reversed-phase high-performance liquid chromatographic-fluorimetric system with lumogallion
    • Wu J, Zhou CY, Chi H, Wong MK, Lee HK, Ong HY, Ong CN. Determination of serum aluminum using an ion-pair reversed-phase high-performance liquid chromatographic-fluorimetric system with lumogallion. J Chromatogr 1995;663:247-53.
    • (1995) J Chromatogr , vol.663 , pp. 247-253
    • Wu, J.1    Zhou, C.Y.2    Chi, H.3    Wong, M.K.4    Lee, H.K.5    Ong, H.Y.6    Ong, C.N.7
  • 15
    • 0022870880 scopus 로고
    • The chemistry of aluminum as related to biology and medicine
    • Martin RB. The chemistry of aluminum as related to biology and medicine [Review]. Clin Chem 1986;32:1797-806.
    • (1986) Clin Chem , vol.32 , pp. 1797-1806
    • Martin, R.B.1
  • 16
    • 0022560413 scopus 로고
    • Metabolism and possible health effects of aluminum
    • Ganrot PO. Metabolism and possible health effects of aluminum. Environ Health Perspect 1986;65:363-441.
    • (1986) Environ Health Perspect , vol.65 , pp. 363-441
    • Ganrot, P.O.1
  • 17
    • 0023819346 scopus 로고
    • Aluminum, chemical physiology, and Alzheimer's disease
    • Birchall JD, Chappell JS. Aluminum, chemical physiology, and Alzheimer's disease. Lancet 1988;ii:1008-10.
    • (1988) Lancet , vol.2 , pp. 1008-1010
    • Birchall, J.D.1    Chappell, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.