메뉴 건너뛰기




Volumn 30, Issue 2, 1996, Pages 137-141

Electrochemical adsorption of glucose oxidase onto polypyrrole film for the construction of a glucose biosensor

Author keywords

Electrochemical adsorption; Glucose biosensors; Glucose oxidase; Polypyrrole

Indexed keywords

ADSORPTION; AGENTS; DEPOSITION; DIFFUSION; ELECTROCHEMICAL ELECTRODES; ELECTROCHEMISTRY; ELECTROPOLYMERIZATION; ENZYMES; ORGANIC COMPOUNDS; ORGANIC POLYMERS; PLASTIC FILMS; PLATINUM;

EID: 0029772683     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/0925-4005(95)01756-L     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 0025671780 scopus 로고
    • Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film
    • C. Malitesta, F. Palmisano, L. Torsi and G. Zambonin, Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film, Anal. Chem., 62 (1990) 2735-2740.
    • (1990) Anal. Chem. , vol.62 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, G.4
  • 2
    • 0026693158 scopus 로고
    • Electrochemical response of an enzyme-loaded polyaniline film
    • J.C. Cooper and E.A.H. Hall, Electrochemical response of an enzyme-loaded polyaniline film, Biosensors Bioelectron., 5 (1992) 473-490.
    • (1992) Biosensors Bioelectron. , vol.5 , pp. 473-490
    • Cooper, J.C.1    Hall, E.A.H.2
  • 3
    • 25144432515 scopus 로고
    • A new conducting polymer-coated glucose sensor
    • P.C. Pandey, A new conducting polymer-coated glucose sensor, J. Chem. Soc., Faraday Trans. I, 84 (1988) 2259-2265.
    • (1988) J. Chem. Soc., Faraday Trans. I , vol.84 , pp. 2259-2265
    • Pandey, P.C.1
  • 4
    • 0023363285 scopus 로고
    • Electrochemical immobilization of enzymes. Part II. Glucose oxidase immobilized in poly-N-methylpyrrole
    • P.N. Bartlett and R.G. Whitaker, Electrochemical immobilization of enzymes. Part II. Glucose oxidase immobilized in poly-N-methylpyrrole, J. Electroanal. Chem., 224 (1987) 37-48.
    • (1987) J. Electroanal. Chem. , vol.224 , pp. 37-48
    • Bartlett, P.N.1    Whitaker, R.G.2
  • 6
    • 0001176752 scopus 로고
    • Electrochemical behavior of monolayerquinoprotein adsorbed in the electrode surface
    • G.F. Khan, H. Shinohara, Y. Ikariyama and M. Aizawa, Electrochemical behavior of monolayerquinoprotein adsorbed in the electrode surface, J. Electroanal. Chem., 315 (1991) 263-273.
    • (1991) J. Electroanal. Chem. , vol.315 , pp. 263-273
    • Khan, G.F.1    Shinohara, H.2    Ikariyama, Y.3    Aizawa, M.4
  • 7
    • 44049110752 scopus 로고
    • Bioelectrochemical responses of the polyaniline uricase electrode
    • M. Shaolin, K. Jinqing and Z. Jianbing, Bioelectrochemical responses of the polyaniline uricase electrode, J. Electroanal. Chem., 334 (1992) 121-232.
    • (1992) J. Electroanal. Chem. , vol.334 , pp. 121-232
    • Shaolin, M.1    Jinqing, K.2    Jianbing, Z.3
  • 8
    • 0026435795 scopus 로고
    • Amperometric polypyrrole enzyme electrodes: Effect of permeability and enzyme location
    • M. Hämmerle, W. Schuhmann and H.-L. Schmidt, Amperometric polypyrrole enzyme electrodes: effect of permeability and enzyme location, Sensors and Actuators B, 6 (1992) 106-112.
    • (1992) Sensors and Actuators B , vol.6 , pp. 106-112
    • Hämmerle, M.1    Schuhmann, W.2    Schmidt, H.-L.3
  • 9
    • 0027308953 scopus 로고
    • Selectivity of conduction polymer electrodes and their application in flow injection analysis of amino acids
    • J.C. Cooper, M. Hämmerle, W. Schuhmann and H.-L. Schmidt, Selectivity of conduction polymer electrodes and their application in flow injection analysis of amino acids, Biosensors Bioelectron., 8 (1993) 65-74.
    • (1993) Biosensors Bioelectron. , vol.8 , pp. 65-74
    • Cooper, J.C.1    Hämmerle, M.2    Schuhmann, W.3    Schmidt, H.-L.4
  • 10
    • 0042396175 scopus 로고
    • Use of different electropolymerization conditions for controlling the size-exclusion selectivity at polyaniline, polypyrrole and polyphenol films
    • J. Wang, S.-P. Chen and M.S. Lin, Use of different electropolymerization conditions for controlling the size-exclusion selectivity at polyaniline, polypyrrole and polyphenol films, J. Electroanal. Chem., 58 (1989) 2979-2983.
    • (1989) J. Electroanal. Chem. , vol.58 , pp. 2979-2983
    • Wang, J.1    Chen, S.-P.2    Lin, M.S.3
  • 11
    • 0023844606 scopus 로고
    • Preparation and electrocatalytic properties of conduction films of polypyrrole containing platinum microparticulates
    • S. Holderoft and B.L. Funt, Preparation and electrocatalytic properties of conduction films of polypyrrole containing platinum microparticulates, J. Electroanal. Chem., 240 (1988) 89-102.
    • (1988) J. Electroanal. Chem. , vol.240 , pp. 89-102
    • Holderoft, S.1    Funt, B.L.2
  • 12
    • 0025282643 scopus 로고
    • Optimization of a polypyrrole glucose oxidase biosensor
    • G. Fortier, E. Brassard and D. Belanger, Optimization of a polypyrrole glucose oxidase biosensor, Biosensors Bioelectron., 5 (1990) 473-490.
    • (1990) Biosensors Bioelectron. , vol.5 , pp. 473-490
    • Fortier, G.1    Brassard, E.2    Belanger, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.