메뉴 건너뛰기




Volumn 51, Issue 8, 1996, Pages 752-756

Control of end-tidal carbon dioxide during IPPV. Variable functional apparatus deadspace

Author keywords

Carbon dioxide, elimination, end tidal; Ventilation, deadspace

Indexed keywords

ADULT; AGED; AIRFLOW; ARTICLE; CLINICAL ARTICLE; CONTROL; END TIDAL CARBON DIOXIDE TENSION; GAS FLOW; GENERAL ANESTHESIA; HUMAN; INTERMITTENT POSITIVE PRESSURE VENTILATION; LUNG MINUTE VOLUME; NERVE BLOCK; REPRODUCIBILITY;

EID: 0029766513     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.1996.tb07890.x     Document Type: Article
Times cited : (3)

References (15)
  • 1
    • 0024989322 scopus 로고
    • Carbon dioxide cylinders on anaesthetic apparatus
    • NUNN JF. Carbon dioxide cylinders on anaesthetic apparatus. British Journal of Anaesthesia 1990; 65: 155-6.
    • (1990) British Journal of Anaesthesia , vol.65 , pp. 155-156
    • Nunn, J.F.1
  • 2
    • 0026355063 scopus 로고
    • Variable apparatus deadspace
    • SCOTT PV, JONES RP. Variable apparatus deadspace. Anaesthesia 1991; 46: 1047-9.
    • (1991) Anaesthesia , vol.46 , pp. 1047-1049
    • Scott, P.V.1    Jones, R.P.2
  • 6
    • 0023334879 scopus 로고
    • Smoking age and the arterial-end tidal Pco: Difference
    • FLETCHER R. Smoking age and the arterial-end tidal Pco: difference. Acta Anaesthesiologica Scandinavica 1987; 31: 355-6.
    • (1987) Acta Anaesthesiologica Scandinavica , vol.31 , pp. 355-356
    • Fletcher, R.1
  • 7
    • 0026637628 scopus 로고
    • The variable deadspace is not necessary
    • FLETCHER R. The variable deadspace is not necessary. Anaesthesia 1992; 47: 623-4.
    • (1992) Anaesthesia , vol.47 , pp. 623-624
    • Fletcher, R.1
  • 9
    • 0027493201 scopus 로고
    • Comparison of end-tidal and arterial carbon dioxide measurements during anaesthesia with the laryngeal mask airway
    • HICKS IR, SONI NC, SHEPHARD JN. Comparison of end-tidal and arterial carbon dioxide measurements during anaesthesia with the laryngeal mask airway. British Journal of Anaesthesia 1993; 71: 734-5.
    • (1993) British Journal of Anaesthesia , vol.71 , pp. 734-735
    • Hicks, I.R.1    Soni, N.C.2    Shephard, J.N.3
  • 10
    • 0028823943 scopus 로고
    • The quality of breathing and capnography during laryngeal mask and facemask ventilation
    • IVENS D, VERBORGH C, PHAN THI H, CAMU F. The quality of breathing and capnography during laryngeal mask and facemask ventilation. Anaesthesia 1995; 50: 858-62.
    • (1995) Anaesthesia , vol.50 , pp. 858-862
    • Ivens, D.1    Verborgh, C.2    Phan Thi, H.3    Camu, F.4
  • 13
    • 0026637628 scopus 로고
    • The variable deadspace is not necessary
    • SCOTT PV, JONES RP. The variable deadspace is not necessary. Anaesthesia 1992; 47: 624.
    • (1992) Anaesthesia , vol.47 , pp. 624
    • Scott, P.V.1    Jones, R.P.2
  • 15
    • 0029393578 scopus 로고
    • 2 cylinders on anaesthetic machines
    • 2 cylinders on anaesthetic machines. Anaesthesia 1995; 50: 911-2.
    • (1995) Anaesthesia , vol.50 , pp. 911-912
    • Todd, D.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.