메뉴 건너뛰기




Volumn 11, Issue 4, 1996, Pages 326-332

Complement activation during and after open-heart surgery is only marginally affected by the choice of fluid for volume replacement

Author keywords

[No Author keywords available]

Indexed keywords

ALBUMIN; DEXTRAN 70; POLYGELINE; RINGER ACETATE;

EID: 0029766194     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1177/026765919601100405     Document Type: Article
Times cited : (4)

References (22)
  • 1
    • 0019418860 scopus 로고
    • Complement activation during cardiopulmonary bypass. Evidence for generation of C3a and C5a analphylatoxins
    • Chenoweth DE, Cooper SW, Hugli TE, Stewart RW, Blackstone EH, Kirklin JW. Complement activation during cardiopulmonary bypass. Evidence for generation of C3a and C5a analphylatoxins. N Engl J Med 1981; 304: 497-503.
    • (1981) N Engl J Med , vol.304 , pp. 497-503
    • Chenoweth, D.E.1    Cooper, S.W.2    Hugli, T.E.3    Stewart, R.W.4    Blackstone, E.H.5    Kirklin, J.W.6
  • 3
    • 0023265798 scopus 로고
    • Complement activation during major operations with and without cardiopulmonary bypass
    • Fosse E, Mollnes TE, Ingvaldsen B. Complement activation during major operations with and without cardiopulmonary bypass. J Thorac Cardiovasc Surg 1987; 93: 806-66.
    • (1987) J Thorac Cardiovasc Surg , vol.93 , pp. 806-866
    • Fosse, E.1    Mollnes, T.E.2    Ingvaldsen, B.3
  • 4
  • 6
    • 0023907877 scopus 로고
    • Complement activation during cardiopulmonary bypass: Comparison between the use of large volumes of plasma and dextran 70
    • Mellbye OJ, Frøland SS, Lilleaasen P, Svennevig JL, Mollnes TE. Complement activation during cardiopulmonary bypass: comparison between the use of large volumes of plasma and dextran 70. Eur Surg Res 1988; 20: 101-109.
    • (1988) Eur Surg Res , vol.20 , pp. 101-109
    • Mellbye, O.J.1    Frøland, S.S.2    Lilleaasen, P.3    Svennevig, J.L.4    Mollnes, T.E.5
  • 7
    • 0025257339 scopus 로고
    • Reduction of complement activation during bypass by prime manipulation
    • Bonser RS, Dave JR, Davies ET et al. Reduction of complement activation during bypass by prime manipulation. Ann Thorac Surg 1990; 49: 279-83.
    • (1990) Ann Thorac Surg , vol.49 , pp. 279-283
    • Bonser, R.S.1    Dave, J.R.2    Davies, E.T.3
  • 8
    • 0028303633 scopus 로고
    • Human complement activation by polygeline and dextran 70
    • Videm V, Mollnes TE. Human complement activation by polygeline and dextran 70. Scand J Immunol 1994; 39: 314-20.
    • (1994) Scand J Immunol , vol.39 , pp. 314-320
    • Videm, V.1    Mollnes, T.E.2
  • 9
    • 0023682533 scopus 로고
    • Complement activation by extracorporeal circulation: Effects of precoating a membrane oxygenator circuit with human whole blood
    • Videm V, Fosse E, Mollnes TE, Garred P. Complement activation by extracorporeal circulation: effects of precoating a membrane oxygenator circuit with human whole blood. Scand J Thorac Cardiovasc Surg 1988; 22: 251-56.
    • (1988) Scand J Thorac Cardiovasc Surg , vol.22 , pp. 251-256
    • Videm, V.1    Fosse, E.2    Mollnes, T.E.3    Garred, P.4
  • 10
  • 11
    • 0023848819 scopus 로고
    • Quantification in ELISA of a C3 neoepitope expressed on activated human complement factor C3
    • Garred P, Mollnes TE, Lea T. Quantification in ELISA of a C3 neoepitope expressed on activated human complement factor C3. Scand J Immunol 1988; 27: 329-35.
    • (1988) Scand J Immunol , vol.27 , pp. 329-335
    • Garred, P.1    Mollnes, T.E.2    Lea, T.3
  • 12
    • 0021850228 scopus 로고
    • Quantification of the terminal complement complex in human plasma by an enzyme-linked immunosorbent assay based on monoclonal antibodies against neoantigen on the complex
    • Mollnes TE, Lea T, Frøland SS, Harboe M. Quantification of the terminal complement complex in human plasma by an enzyme-linked immunosorbent assay based on monoclonal antibodies against neoantigen on the complex. Scand J Immunol 1985; 22: 197-202.
    • (1985) Scand J Immunol , vol.22 , pp. 197-202
    • Mollnes, T.E.1    Lea, T.2    Frøland, S.S.3    Harboe, M.4
  • 13
    • 0017355708 scopus 로고
    • The effects of cardiopulmonary bypass with crystalloid and colloid hemodilution on myocardial extravascular water
    • Laks H, Standeven J, Blair O, Hahn J, Jellinek M, Willman VL. The effects of cardiopulmonary bypass with crystalloid and colloid hemodilution on myocardial extravascular water. J Thorac Cardiovasc Surg 1977; 73: 129-37.
    • (1977) J Thorac Cardiovasc Surg , vol.73 , pp. 129-137
    • Laks, H.1    Standeven, J.2    Blair, O.3    Hahn, J.4    Jellinek, M.5    Willman, V.L.6
  • 14
    • 0023238526 scopus 로고
    • Restoration of volume by crystalloid versus colloid after coronary artery bypass: Hemodynamics, lung water, oxygenation, and outcome
    • Karenko MS, Klossner JA, Laaksonen VO. Restoration of volume by crystalloid versus colloid after coronary artery bypass: hemodynamics, lung water, oxygenation, and outcome. Crit Care Med 1987; 15: 559-66.
    • (1987) Crit Care Med , vol.15 , pp. 559-566
    • Karenko, M.S.1    Klossner, J.A.2    Laaksonen, V.O.3
  • 15
    • 0025008769 scopus 로고
    • Crystalloid versus colloid fluid therapy after cardiac surgery
    • Ley SJ, Miller K, Skov P, Preisig P. Crystalloid versus colloid fluid therapy after cardiac surgery. Heart Lung 1990; 19: 31-40.
    • (1990) Heart Lung , vol.19 , pp. 31-40
    • Ley, S.J.1    Miller, K.2    Skov, P.3    Preisig, P.4
  • 16
    • 0023942152 scopus 로고
    • Complement activation during cardiopulmonary bypass: Attenuation by hypothermia, heparin, and hemodilution
    • Tamiya T, Yamasaki M, Maeo Y, Yamashiro T, Ogoshi S, Fujimoto S. Complement activation during cardiopulmonary bypass: attenuation by hypothermia, heparin, and hemodilution. Ann Surg 1988; 208: 95-193.
    • (1988) Ann Surg , vol.208 , pp. 95-193
    • Tamiya, T.1    Yamasaki, M.2    Maeo, Y.3    Yamashiro, T.4    Ogoshi, S.5    Fujimoto, S.6
  • 17
    • 0021878943 scopus 로고
    • Deleterious effects of cardiopulmonary bypass. A prospective study of bubble versus membrane oxygenation
    • van Oeveren W, Kazatchkene MD, Descamps-Latscha B et al. Deleterious effects of cardiopulmonary bypass. A prospective study of bubble versus membrane oxygenation. J Thorac Cardiovasc Surg 1985; 89: 888-99.
    • (1985) J Thorac Cardiovasc Surg , vol.89 , pp. 888-899
    • Van Oeveren, W.1    Kazatchkene, M.D.2    Descamps-Latscha, B.3
  • 18
    • 0025054633 scopus 로고
    • Complement activation with bubble and membrane oxygenators in aortocoronary bypass surgery
    • Videm V, Fosse E, Mollnes TE, Garred P, Svennevig JL. Complement activation with bubble and membrane oxygenators in aortocoronary bypass surgery. Ann Thorac Surg 1990; 50: 387-91.
    • (1990) Ann Thorac Surg , vol.50 , pp. 387-391
    • Videm, V.1    Fosse, E.2    Mollnes, T.E.3    Garred, P.4    Svennevig, J.L.5
  • 21
    • 0023942152 scopus 로고
    • The effects of complement activation during cardiopulmonary bypass: Attenuation by hypothermia, heparin, and hemodilution
    • Moore FD, Warner KG, Assousa S, Valeri CR, Khuri SF. The effects of complement activation during cardiopulmonary bypass: attenuation by hypothermia, heparin, and hemodilution. Ann Surg 1988; 208: 95-103.
    • (1988) Ann Surg , vol.208 , pp. 95-103
    • Moore, F.D.1    Warner, K.G.2    Assousa, S.3    Valeri, C.R.4    Khuri, S.F.5
  • 22
    • 84970301722 scopus 로고
    • Complement consumption during cardiopulmonary bypass: Bubble versus membrane oxygenators
    • Mickleborough LL, Arnold G, Chiu RC. Complement consumption during cardiopulmonary bypass: bubble versus membrane oxygenators. Perfusion 1986; 1: 261-69.
    • (1986) Perfusion , vol.1 , pp. 261-269
    • Mickleborough, L.L.1    Arnold, G.2    Chiu, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.