메뉴 건너뛰기




Volumn 112, Issue 1, 1996, Pages 59-68

Clinical experience with the carbomedics valve: Early results with a new bileaflet mechanical prosthesis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA VALVE REPLACEMENT; ARTICLE; CLINICAL OBSERVATION; DEVICE; FEMALE; FOLLOW UP; HEART VALVE PROSTHESIS; HUMAN; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REPLACEMENT; PRIORITY JOURNAL; REOPERATION; THROMBOGENESIS; THROMBOSIS;

EID: 0029756633     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-5223(96)70178-2     Document Type: Article
Times cited : (26)

References (28)
  • 1
    • 0000882118 scopus 로고
    • Valvular heart disease: cardiac valve replacement
    • FJ. Schoen Valvular heart disease: cardiac valve replacement FJ Schoen Interventional and surgical cardiovascular pathology: clinical correlations and basic principles 1989 WB Saunders Philadelphia 109 171
    • (1989) , pp. 109-171
    • Schoen, FJ.1
  • 2
    • 0022971195 scopus 로고
    • Durability and low thrombogenicity of the St. Jude Medical valve at 5-year follow-up
    • JM Duncan DA Cooley GJ Reul Durability and low thrombogenicity of the St. Jude Medical valve at 5-year follow-up Ann Thorac Surg 42 1986 500 505
    • (1986) Ann Thorac Surg , vol.42 , pp. 500-505
    • Duncan, JM1    Cooley, DA2    Reul, GJ3
  • 3
    • 0027359452 scopus 로고
    • St. Jude prosthesis for aortic and mitral valve replacement: a ten year experience
    • JM Kratz FA Crawford RM Sade AJ Crumbley MR. Stroud St. Jude prosthesis for aortic and mitral valve replacement: a ten year experience Ann Thorac Surg 56 1993 462 468
    • (1993) Ann Thorac Surg , vol.56 , pp. 462-468
    • Kratz, JM1    Crawford, FA2    Sade, RM3    Crumbley, AJ4    Stroud, MR.5
  • 4
    • 0028099745 scopus 로고
    • The St. Jude Medical valve: experience with 1000 cases
    • S Khan A Chaux J Matloff The St. Jude Medical valve: experience with 1000 cases J Thorac Cardiovasc Surg 108 1994 1010 1020
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 1010-1020
    • Khan, S1    Chaux, A2    Matloff, J3
  • 6
    • 0023758391 scopus 로고
    • Guidelines for reporting morbidity and mortality after cardiac valvular operations
    • LH Edmunds RE Clark LH Cohn DC Miller RD. Wesel Guidelines for reporting morbidity and mortality after cardiac valvular operations J Thorac Cardiovasc Surg 96 1988 351 353
    • (1988) J Thorac Cardiovasc Surg , vol.96 , pp. 351-353
    • Edmunds, LH1    Clark, RE2    Cohn, LH3    Miller, DC4    Wesel, RD.5
  • 7
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • EL Kaplan P. Meier Nonparametric estimation from incomplete observations J Am Stat Assoc 53 1958 457 481
    • (1958) J Am Stat Assoc , vol.53 , pp. 457-481
    • Kaplan, EL1    Meier, P.2
  • 9
    • 0002076273 scopus 로고
    • Evaluation of a double-leaflet prosthetic heart valve of new design for clinical use
    • BR Kalke CW Lillehei RL. Kaster Evaluation of a double-leaflet prosthetic heart valve of new design for clinical use LA Brewer Prosthetic heart valves 1969 Charles Thomas Springfield, Illinois 285 302
    • (1969) , pp. 285-302
    • Kalke, BR1    Lillehei, CW2    Kaster, RL.3
  • 10
    • 0018743410 scopus 로고
    • A new cardiac prosthesis: the St. Jude Medical cardiac valve–in vivo results
    • RW Emery E Mettler DM. Nicoloff A new cardiac prosthesis: the St. Jude Medical cardiac valve–in vivo results Circulation 60 Suppl 1979 II148 II154
    • (1979) Circulation , vol.60 , Issue.Suppl , pp. II148-II154
    • Emery, RW1    Mettler, E2    Nicoloff, DM.3
  • 12
    • 0018722398 scopus 로고
    • The St. Jude Medical cardiac valve prosthesis: in vitro studies
    • RW Emery DM. Nicoloff The St. Jude Medical cardiac valve prosthesis: in vitro studies J Thorac Cardiovasc Surg 78 1979 269 276
    • (1979) J Thorac Cardiovasc Surg , vol.78 , pp. 269-276
    • Emery, RW1    Nicoloff, DM.2
  • 13
    • 0021742736 scopus 로고
    • The St. Jude Medical bileaflet valve prosthesis: a 5 year experience
    • A Chaux LSC Czer JM Matloff The St. Jude Medical bileaflet valve prosthesis: a 5 year experience J Thorac Cardiovasc Surg 88 1984 706 717
    • (1984) J Thorac Cardiovasc Surg , vol.88 , pp. 706-717
    • Chaux, A1    Czer, LSC2    Matloff, JM3
  • 14
    • 0024339701 scopus 로고
    • Clinical and ultrasound results after aortic valve replacement: intermediate-term follow-up with the St. Jude Medical prosthesis
    • G Montalescot D Thomas G Drobinsky Clinical and ultrasound results after aortic valve replacement: intermediate-term follow-up with the St. Jude Medical prosthesis Am Heart J 118 1989 104 113
    • (1989) Am Heart J , vol.118 , pp. 104-113
    • Montalescot, G1    Thomas, D2    Drobinsky, G3
  • 16
    • 0026757239 scopus 로고
    • Analysis of left ventricular motion after mitral valve replacement with a technique of preservation of all chordae tendineae: comparison with conventional mitral valve replacement or mitral valve repair
    • Y Okita S Miki K Kusuhara Analysis of left ventricular motion after mitral valve replacement with a technique of preservation of all chordae tendineae: comparison with conventional mitral valve replacement or mitral valve repair J Thorac Cardiovasc Surg 104 1992 786 795
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 786-795
    • Okita, Y1    Miki, S2    Kusuhara, K3
  • 17
    • 0026527253 scopus 로고
    • Hemodynamic evaluation of the CarboMedics prosthetic heart valve in the aortic position: comparison of noninvasive and invasive techniques
    • H Ihlen P Mostad S Simonsen Hemodynamic evaluation of the CarboMedics prosthetic heart valve in the aortic position: comparison of noninvasive and invasive techniques Am Heart J 123 1992 151 159
    • (1992) Am Heart J , vol.123 , pp. 151-159
    • Ihlen, H1    Mostad, P2    Simonsen, S3
  • 18
    • 0027499532 scopus 로고
    • Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve
    • J Chambers M Cross PB Deverall E. Sowton Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve J Am Coll Cardiol 21 1993 398 405
    • (1993) J Am Coll Cardiol , vol.21 , pp. 398-405
    • Chambers, J1    Cross, M2    Deverall, PB3    Sowton, E.4
  • 19
    • 0022592192 scopus 로고
    • Significant patient-related determinants of prosthetic valve performance
    • RS Mitchell DC Miller EB Stinson Significant patient-related determinants of prosthetic valve performance J Thorac Cardiovasc Surg 91 1986 807 817
    • (1986) J Thorac Cardiovasc Surg , vol.91 , pp. 807-817
    • Mitchell, RS1    Miller, DC2    Stinson, EB3
  • 20
    • 0020694804 scopus 로고
    • Valvular heart disease: a perspective
    • SH. Rahimtoola Valvular heart disease: a perspective J Am Coll Cardiol 1 1983 199 215
    • (1983) J Am Coll Cardiol , vol.1 , pp. 199-215
    • Rahimtoola, SH.1
  • 21
    • 0026658628 scopus 로고
    • Oral anticoagulants: mechanism of action, clinical effectiveness and optimal theraupeutic range
    • J Hirsh JE Dalen D Deykin L. Poller Oral anticoagulants: mechanism of action, clinical effectiveness and optimal theraupeutic range Chest 102 Suppl 1992 445S 455S
    • (1992) Chest , vol.102 , Issue.Suppl , pp. 445S-455S
    • Hirsh, J1    Dalen, JE2    Deykin, D3    Poller, L.4
  • 22
    • 4243624816 scopus 로고
    • Five years experience with the Björk-Shiley Monostrut valve in 2726 patients: a Spanish multicentre study
    • L Castillón JG Pareja MC Ruiz MAG Jiménez C Infantes E. Pérez-Duarte Five years experience with the Björk-Shiley Monostrut valve in 2726 patients: a Spanish multicentre study E Bodnar Surgery for heart valve disease. 1989 Proceedings of the 1989 Symposium London 268 285
    • (1989) , pp. 268-285
    • Castillón, L1    Pareja, JG2    Ruiz, MC3    Jiménez, MAG4    Infantes, C5    Pérez-Duarte, E.6
  • 23
    • 0028890546 scopus 로고
    • An international experience with the CarboMedics prosthetic heart valve
    • JG. Copeland An international experience with the CarboMedics prosthetic heart valve J Heart Valve Dis 4 1995 56 62
    • (1995) J Heart Valve Dis , vol.4 , pp. 56-62
    • Copeland, JG.1
  • 25
    • 0025762084 scopus 로고
    • Comparison of two levels of anticoagulant therapy in patients with substitute heart valves
    • R Altman J Rouvier E Gurfinkel Comparison of two levels of anticoagulant therapy in patients with substitute heart valves J Thorac Cardiovasc Surg 101 1991 427 431
    • (1991) J Thorac Cardiovasc Surg , vol.101 , pp. 427-431
    • Altman, R1    Rouvier, J2    Gurfinkel, E3
  • 26
    • 0025128956 scopus 로고
    • Trial of different intensities of anticoagulation in patients with prosthetic heart valves
    • JN Saour JO Steck LAR Mamo AS. Gallus Trial of different intensities of anticoagulation in patients with prosthetic heart valves N Engl J Med 322 1990 428 432
    • (1990) N Engl J Med , vol.322 , pp. 428-432
    • Saour, JN1    Steck, JO2    Mamo, LAR3    Gallus, AS.4
  • 28
    • 0029041949 scopus 로고
    • Aiming for safe anticoagulation
    • SD. Fihn Aiming for safe anticoagulation N Engl J Med 333 1995 54 55
    • (1995) N Engl J Med , vol.333 , pp. 54-55
    • Fihn, SD.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.