메뉴 건너뛰기




Volumn 30, Issue 3, 1996, Pages 179-183

Performance of glucose biosensor based on oxygen electrode in physiological fluids and at body temperature

Author keywords

Glucose biosensor; Glucose monitoring; Oxygen electrodes

Indexed keywords

AMPEROMETRIC SENSORS; BLOOD GAS ANALYSIS; BODY FLUIDS; GAS SENSING ELECTRODES; IMPLANTS (SURGICAL); OXYGEN SENSORS; PHYSIOLOGY; POLYMERIC MEMBRANES; THERMAL EFFECTS;

EID: 0029754190     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/0925-4005(96)80046-3     Document Type: Article
Times cited : (13)

References (15)
  • 1
    • 84908830001 scopus 로고
    • Can continuous glucose monitoring be used for the treatment of diabetes
    • G. Reach and G.S. Wilson, Can continuous glucose monitoring be used for the treatment of diabetes, Anal. Chem., 64 (1992) 381A-386A.
    • (1992) Anal. Chem. , vol.64
    • Reach, G.1    Wilson, G.S.2
  • 3
    • 0024514006 scopus 로고
    • In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method
    • J. Bruckel, W. Kerner, H. Zeir, G. Steibach and E.F. Pfeiffer, In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method, Klin Wochenschr., 67 (1989) 491-495.
    • (1989) Klin Wochenschr. , vol.67 , pp. 491-495
    • Bruckel, J.1    Kerner, W.2    Zeir, H.3    Steibach, G.4    Pfeiffer, E.F.5
  • 4
    • 0026628622 scopus 로고
    • Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials
    • C.Y. Chen, M. Gotoh, H. Makino, Y.C. Su, E. Tamia and I. Karube, Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials, Anal. Chim. Acta, 265 (1992) 5-14.
    • (1992) Anal. Chim. Acta , vol.265 , pp. 5-14
    • Chen, C.Y.1    Gotoh, M.2    Makino, H.3    Su, Y.C.4    Tamia, E.5    Karube, I.6
  • 5
    • 0020134817 scopus 로고
    • Implanted electroenzymated glucose sensors
    • L.C. Clark and C. Duggon, Implanted electroenzymated glucose sensors, Diabetes Care, 5 (1982) 174-180.
    • (1982) Diabetes Care , vol.5 , pp. 174-180
    • Clark, L.C.1    Duggon, C.2
  • 6
    • 0026546742 scopus 로고
    • Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
    • D. Moatti-Sirat, F. Copron, V. Poitout, G. Reach, D.S. Bindra, Y. Zhang, G.S. Wilson and D.R. Thevenot, Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue, Diabetologia, 35 (1992) 224-230.
    • (1992) Diabetologia , vol.35 , pp. 224-230
    • Moatti-Sirat, D.1    Copron, F.2    Poitout, V.3    Reach, G.4    Bindra, D.S.5    Zhang, Y.6    Wilson, G.S.7    Thevenot, D.R.8
  • 7
    • 0027703663 scopus 로고
    • The use of polycarbonate membranes coated with charged polymers to reduce the interference effect on glucose measurements
    • R. Vaidya and E. Wilkins, The use of polycarbonate membranes coated with charged polymers to reduce the interference effect on glucose measurements, Biomed. Instrum. Technol., 27 (1993) 486-494.
    • (1993) Biomed. Instrum. Technol. , vol.27 , pp. 486-494
    • Vaidya, R.1    Wilkins, E.2
  • 8
    • 10244223555 scopus 로고
    • Electrode system for continuous monitoring in cardiovascular surgery
    • L.C. Clark and C. Lyons, Electrode system for continuous monitoring in cardiovascular surgery, Ann. N.Y. Acad. Sci., 102 (1962) 29-45.
    • (1962) Ann. N.Y. Acad. Sci. , vol.102 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 9
    • 0023346438 scopus 로고
    • Long term in vitro operation of enzyme electrode based glucose sensor
    • P.J. Conway and D.A. Gough, Long term in vitro operation of enzyme electrode based glucose sensor, Sensors and Actuators, 11 (1987) 305-308.
    • (1987) Sensors and Actuators , vol.11 , pp. 305-308
    • Conway, P.J.1    Gough, D.A.2
  • 10
    • 0023306484 scopus 로고
    • In vitro stability of an oxygen sensor
    • J.Y. Lucisano, J.C. Armor and D.A. Gough, In vitro stability of an oxygen sensor, Anal. Chem., 59 (1987) 736-739.
    • (1987) Anal. Chem. , vol.59 , pp. 736-739
    • Lucisano, J.Y.1    Armor, J.C.2    Gough, D.A.3
  • 11
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • J.C. Armor, J.Y. Lucisano, B.D. McKean and D.A. Gough, Application of chronic intravascular blood glucose sensor in dogs, Diabetes, 39 (1990) 1519-1526.
    • (1990) Diabetes , vol.39 , pp. 1519-1526
    • Armor, J.C.1    Lucisano, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 12
    • 0026220296 scopus 로고
    • Rechargeable glucose electrodes for long-term implantation
    • S.L. Xie and E. Wilkins, Rechargeable glucose electrodes for long-term implantation, J. Biomed. Eng., 13 (1991) 375-378.
    • (1991) J. Biomed. Eng. , vol.13 , pp. 375-378
    • Xie, S.L.1    Wilkins, E.2
  • 13
    • 0027624475 scopus 로고
    • A rechargeable glucose sensor - Long term activity and performance
    • E. Wilkins, A rechargeable glucose sensor - long term activity and performance, Biomed. Instrum. Technol., 27 (1993) 325-333.
    • (1993) Biomed. Instrum. Technol. , vol.27 , pp. 325-333
    • Wilkins, E.1
  • 14
    • 84973003408 scopus 로고
    • Glucose biosensor based on oxygen electrode. Part I: Silastic coated polycarbonate membranes for biosensor application
    • P. Atanasov and E. Wilkins, Glucose biosensor based on oxygen electrode. Part I: silastic coated polycarbonate membranes for biosensor application, Anal. Lett., 26 (1993) 1587-1612.
    • (1993) Anal. Lett. , vol.26 , pp. 1587-1612
    • Atanasov, P.1    Wilkins, E.2
  • 15
    • 0043230063 scopus 로고
    • Glucose biosensor based on oxygen electrode. Part II: Long term operational stability of the rechargeable glucose biosensor
    • P. Atanasov and E. Wilkins, Glucose biosensor based on oxygen electrode. Part II: long term operational stability of the rechargeable glucose biosensor, Anal. Lett., 26 (1993) 2079-2094.
    • (1993) Anal. Lett. , vol.26 , pp. 2079-2094
    • Atanasov, P.1    Wilkins, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.