메뉴 건너뛰기




Volumn 6, Issue 1, 1996, Pages 47-66

Prevention of platelet adhesion on the polysulfone porous catheter by saline solution perfusion, I. In vitro investigation

Author keywords

Blood compatibility; Platelet adhesion; Polysulfone porous catheter tube; Saline perfusion; Surface modification

Indexed keywords

BIOMATERIAL; CETOMACROGOL; MACROGOL DERIVATIVE; POLITEF; POLYMER; POLYOXYETHYLENE OLEYL ETHER; POLYSULFONE P 1700; SODIUM CHLORIDE; SULFONE; SURFACTANT; VEGETABLE OIL;

EID: 0029705392     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: 10.3233/bme-1996-6104     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0028301955 scopus 로고
    • New processes for surface treatment of catheter
    • P. Sioshansi, New processes for surface treatment of catheter, Artif. Organs. 18 (1994), 266-271.
    • (1994) Artif. Organs , vol.18 , pp. 266-271
    • Sioshansi, P.1
  • 2
    • 0027657488 scopus 로고
    • Surface modification of intravenous catheter to reduce local tissue reactions
    • J.-H. Elam and M. Elam, Surface modification of intravenous catheter to reduce local tissue reactions, Biomaterials 14 (1993), 861-864.
    • (1993) Biomaterials , vol.14 , pp. 861-864
    • Elam, J.-H.1    Elam, M.2
  • 4
    • 0018653030 scopus 로고
    • Thrombus formation and renal infarction induced by aortic catheters in sheep
    • J.F. Hecker, Thrombus formation and renal infarction induced by aortic catheters in sheep, Trans. Am. Soc. Artificial Internal Organs. 25 (1979), 294-297.
    • (1979) Trans. Am. Soc. Artificial Internal Organs , vol.25 , pp. 294-297
    • Hecker, J.F.1
  • 5
    • 0022044951 scopus 로고
    • Roughness and thrombogenicity of the outer surfaces of intravascular catheter
    • J.F. Hecker and L.A. Scandrett, Roughness and thrombogenicity of the outer surfaces of intravascular catheter, J. Biomed. Mater. Res. 19 (1985), 381-395.
    • (1985) J. Biomed. Mater. Res. , vol.19 , pp. 381-395
    • Hecker, J.F.1    Scandrett, L.A.2
  • 6
    • 0000368601 scopus 로고
    • Surface modification of polymers for improved blood compatibility
    • S.W. Kim and J. Feijen, Surface modification of polymers for improved blood compatibility, CRC Critical Rev. Biocompatibility 1 (1985), 229-260.
    • (1985) CRC Critical Rev. Biocompatibility , vol.1 , pp. 229-260
    • Kim, S.W.1    Feijen, J.2
  • 7
    • 0023613971 scopus 로고
    • Modification of material surfaces to affect how they interact with blood
    • A.S. Hoffman, Modification of material surfaces to affect how they interact with blood, Annal. New York Acad. Sci. 516 (1987), 96-101.
    • (1987) Annal. New York Acad. Sci. , vol.516 , pp. 96-101
    • Hoffman, A.S.1
  • 8
    • 85167422727 scopus 로고
    • The importance of vascular graft surface composition as demonstrated by a new gas discharge treatment for small diameter grafts, in
    • H. Kambic, A. Kantorwitz and P. Sung, eds, ASTM, Philadelphia
    • A.S. Hoffman, B.D. Ratner, A.M. Garfinkle, L.O. Reynolds, T.A. Horbert and S.R. Hanson, The importance of vascular graft surface composition as demonstrated by a new gas discharge treatment for small diameter grafts, in: Vascular Graft Update, H. Kambic, A. Kantorwitz and P. Sung, eds, ASTM, Philadelphia, 1986, pp. 137-155.
    • (1986) Vascular Graft Update , pp. 137-155
    • Hoffman, A.S.1    Ratner, B.D.2    Garfinkle, A.M.3    Reynolds, L.O.4    Horbert, T.A.5    Hanson, S.R.6
  • 10
    • 0024635932 scopus 로고
    • Protein-resistant surfaces prepared by PEO-containing block copolymer surfactant
    • J.H. Lee, J. Kopececk and J.D. Andrade, Protein-resistant surfaces prepared by PEO-containing block copolymer surfactant, J. Biomed. Mater. Res. 23 (1989), 351-368.
    • (1989) J. Biomed. Mater. Res. , vol.23 , pp. 351-368
    • Lee, J.H.1    Kopececk, J.2    Andrade, J.D.3
  • 11
    • 0017534257 scopus 로고    scopus 로고
    • Blood-compatible materials by fluid perfusion
    • P. Predecki and P.A. Russell, Blood-compatible materials by fluid perfusion, J. Biomed. Mater. Res. 11 (1997), 767-786.
    • (1997) J. Biomed. Mater. Res. , vol.11 , pp. 767-786
    • Predecki, P.1    Russell, P.A.2
  • 12
    • 0019036910 scopus 로고
    • Prevention of platelet adhesion to porous surfaces
    • P. Predecki, L. Life and M.M. Newman, Prevention of platelet adhesion to porous surfaces, J. Biomed. Mater. Res. 14 (1980), 405-415.
    • (1980) J. Biomed. Mater. Res. , vol.14 , pp. 405-415
    • Predecki, P.1    Life, L.2    Newman, M.M.3
  • 13
    • 0019378239 scopus 로고
    • Prevention of erythrocyte adhesion onto porous surfaces by fluid perfusion
    • D.R. Clark and J.B. Park, Prevention of erythrocyte adhesion onto porous surfaces by fluid perfusion, Biomaterials 2 (1981), 9-13.
    • (1981) Biomaterials , vol.2 , pp. 9-13
    • Clark, D.R.1    Park, J.B.2
  • 14
    • 0027620855 scopus 로고
    • Prevention of blood cell adhesion of porous inner wall of double-layered tube by saline perfusion
    • S.S. Kim and J.B. Park, Prevention of blood cell adhesion of porous inner wall of double-layered tube by saline perfusion, Bio-Med. Mat. Eng. 3 (1993), 85-100.
    • (1993) Bio-Med. Mat. Eng. , vol.3 , pp. 85-100
    • Kim, S.S.1    Park, J.B.2
  • 15
    • 0027620679 scopus 로고
    • Prevention of mural thrombus in porous inner tube of double-layered tube by saline perfusion
    • J.B. Park and S.S. Kim, Prevention of mural thrombus in porous inner tube of double-layered tube by saline perfusion, Bio-Med. Mat. Eng. 3 (1993), 101-116.
    • (1993) Bio-Med. Mat. Eng. , vol.3 , pp. 101-116
    • Park, J.B.1    Kim, S.S.2
  • 16
    • 0029440789 scopus 로고
    • Biocompatibility of polysulfone. I, Surface treatment and characterizations
    • G. Khang, H.B. Lee and J.B. Park, Biocompatibility of polysulfone. I, Surface treatment and characterizations, Bio-Med. Mat. Eng. 5 (1995), 245-258.
    • (1995) Bio-Med. Mat. Eng. , vol.5 , pp. 245-258
    • Khang, G.1    Lee, H.B.2    Park, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.