메뉴 건너뛰기




Volumn 36, Issue 1, 1996, Pages 61-65

T1 and T2 of ferritin solutions: Effect of loading factor

Author keywords

ferritin; iron; relaxation enhancement; relaxometry

Indexed keywords

IRON; METAL IONS; PROTEINS; QUANTUM THEORY;

EID: 0029665601     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910360111     Document Type: Article
Times cited : (80)

References (43)
  • 1
    • 0020559433 scopus 로고
    • Nuclear magnetic resonance imaging of experimentally induced liver disease
    • D. D. Stark, N. M. Bass, A. A. Moss, et al., Nuclear magnetic resonance imaging of experimentally induced liver disease. Radiology 148, 743-751 (1983).
    • (1983) Radiology , vol.148 , pp. 743-751
    • Stark, D.D.1    Bass, N.M.2    Moss, A.A.3
  • 5
    • 0345312617 scopus 로고
    • Magnetic resonance imaging of brain iron using a 4 Tesla whole-body scanner
    • R. B. Frankel, R. P. Blakemore, Eds., Plenum Press, New York
    • J. F. Schenck, O. M. Mueller, S. P. Souza, C. L. Dumoulin, Magnetic resonance imaging of brain iron using a 4 Tesla whole-body scanner, in "Iron Biominerals" (R. B. Frankel, R. P. Blakemore, Eds.), pp. 373-385, Plenum Press, New York, 1990.
    • (1990) Iron Biominerals , pp. 373-385
    • Schenck, J.F.1    Mueller, O.M.2    Souza, S.P.3    Dumoulin, C.L.4
  • 6
    • 0027449943 scopus 로고
    • Age distribution and iron dependency of the T2 relaxation time in the globus pallidus and putamen
    • C. Schenker, D. Meier, W. Wichmann, P. Boesiger, A. Alavanis, Age distribution and iron dependency of the T2 relaxation time in the globus pallidus and putamen. Neuroradiology 35, 119-124 (1993).
    • (1993) Neuroradiology , vol.35 , pp. 119-124
    • Schenker, C.1    Meier, D.2    Wichmann, W.3    Boesiger, P.4    Alavanis, A.5
  • 7
    • 0024325997 scopus 로고
    • T2 values in the human brain: Comparison with quantitative assays of iron and ferritin
    • J. C. Chen, P. A. Hardy, M. Clausberg, et al., T2 values in the human brain: comparison with quantitative assays of iron and ferritin. Radiology 173, 521-526 (1989).
    • (1989) Radiology , vol.173 , pp. 521-526
    • Chen, J.C.1    Hardy, P.A.2    Clausberg, M.3
  • 8
    • 0024763349 scopus 로고
    • Basal ganglia: Significance of signal hypointensity on T2-weighted MR images
    • B. P. Drayer, Basal ganglia: significance of signal hypointensity on T2-weighted MR images. Radiology 173, 311-312 (1989).
    • (1989) Radiology , vol.173 , pp. 311-312
    • Drayer, B.P.1
  • 9
    • 0027157364 scopus 로고
    • MR of human postmortem brain tissue: Correlative study between T2 and assays of iron and ferritin in Parkinson and Huntington disease
    • J. C. Chen, P. A. Hardy, W. Kucharczyk, et al., MR of human postmortem brain tissue: correlative study between T2 and assays of iron and ferritin in Parkinson and Huntington disease. AJNR 14, 275-281 (1993).
    • (1993) AJNR , vol.14 , pp. 275-281
    • Chen, J.C.1    Hardy, P.A.2    Kucharczyk, W.3
  • 11
    • 0027250678 scopus 로고
    • The relation between regional brain iron and T2-shortening
    • J.M. Gomori, R. I. Grossman, The relation between regional brain iron and T2-shortening. AJNR 14, 1049-1050 (1993).
    • (1993) AJNR , vol.14 , pp. 1049-1050
    • Gomori, J.M.1    Grossman, R.I.2
  • 12
    • 0025141166 scopus 로고
    • Role of iron and ferritin in MR imaging of the brain: A study in primates at different field strengths
    • A. Bizzi, R. A. Brooks, A. Brunetti, et al. Role of iron and ferritin in MR imaging of the brain: a study in primates at different field strengths. Radiology 177, 59-65 (1990).
    • (1990) Radiology , vol.177 , pp. 59-65
    • Bizzi, A.1    Brooks, R.A.2    Brunetti, A.3
  • 13
    • 0002918147 scopus 로고
    • Studies of diffusion in random fields produced by variations in susceptibility
    • S. Majumdar, J. C. Gore, Studies of diffusion in random fields produced by variations in susceptibility. J. Magn. Reson. 78, 41-55 (1988).
    • (1988) J. Magn. Reson. , vol.78 , pp. 41-55
    • Majumdar, S.1    Gore, J.C.2
  • 14
    • 0024400136 scopus 로고
    • Transverse relaxation rate enhancement caused by magnetic particulates
    • P. A. Hardy, R. M. Henkelman, Transverse relaxation rate enhancement caused by magnetic particulates. Magn. Reson. Imaging 7, 265-275 (1989).
    • (1989) Magn. Reson. Imaging , vol.7 , pp. 265-275
    • Hardy, P.A.1    Henkelman, R.M.2
  • 15
    • 0025976594 scopus 로고
    • On the transverse relaxation rate enhancement induced by diffusion of spins through inhomogeneous fields
    • P. A. Hardy, M. Henkelman, On the transverse relaxation rate enhancement induced by diffusion of spins through inhomogeneous fields. Magn. Reson. Med. 17, 348-356 (1991).
    • (1991) Magn. Reson. Med. , vol.17 , pp. 348-356
    • Hardy, P.A.1    Henkelman, M.2
  • 16
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numerical simulations and applications to cerebral physiology
    • C. R. Fisel, J. L. Ackerman, R. B. Buxton, L. Garrido, J. W. Belliveau, B. R. Rosen, T. J. Brady, MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Magn. Reson. Med. 17, 336-347 (1991).
    • (1991) Magn. Reson. Med. , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3    Garrido, L.4    Belliveau, J.W.5    Rosen, B.R.6    Brady, T.J.7
  • 17
    • 0026335291 scopus 로고
    • Transverse relaxivity of particulate MRI contrast media: From theories to experiments
    • R. N. Muller, P. Gillis, F. Moiny, A. Roch, Transverse relaxivity of particulate MRI contrast media: from theories to experiments. Magn. Reson. Med. 22, 178-182 (1991).
    • (1991) Magn. Reson. Med. , vol.22 , pp. 178-182
    • Muller, R.N.1    Gillis, P.2    Moiny, F.3    Roch, A.4
  • 18
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: Theory and experiment
    • R. M. Weisskoff, C. S. Zuo, J. L. Boxerman, B. R. Rosen, Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn. Reson. Med. 31, 601-610 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 601-610
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 19
    • 0028843058 scopus 로고
    • Proton transverse nuclear magnetic relaxation in oxidized blood: A numerical approach
    • P. Gillis, S. Peto, F. Moiny, J. Mispelter, C. A. Cuenod, Proton transverse nuclear magnetic relaxation in oxidized blood: a numerical approach. Magn. Reson. Med. 33, 93-100 (1995).
    • (1995) Magn. Reson. Med. , vol.33 , pp. 93-100
    • Gillis, P.1    Peto, S.2    Moiny, F.3    Mispelter, J.4    Cuenod, C.A.5
  • 20
    • 0027420138 scopus 로고
    • Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores
    • G. Bartzokis, M. Aravagiri, W. H. Oldendorf, J. Mintz, S. R. Marder, Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores. Magn. Reson. Med. 29, 459-464 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 459-464
    • Bartzokis, G.1    Aravagiri, M.2    Oldendorf, W.H.3    Mintz, J.4    Marder, S.R.5
  • 21
    • 0028318873 scopus 로고
    • In vivo MR evaluation of age-related increases in brain iron
    • G. Bartzokis, J. Mintz, D. Sultzer, et al., In vivo MR evaluation of age-related increases in brain iron. Am. J. Neuroradiol. 15, 1129-1138 (1994).
    • (1994) Am. J. Neuroradiol. , vol.15 , pp. 1129-1138
    • Bartzokis, G.1    Mintz, J.2    Sultzer, D.3
  • 24
    • 0029364588 scopus 로고
    • The quantitative relation between T2 and T2-weighted MRI of normal gray matter and iron concentration
    • J. Vymazal, M. Hajek, N. Patronas, J. N. Giedd, J. W. M. Bulte, R. A. Brooks, The quantitative relation between T2 and T2-weighted MRI of normal gray matter and iron concentration. J. Magn. Reson. Imaging 5, 554-560 (1995).
    • (1995) J. Magn. Reson. Imaging , vol.5 , pp. 554-560
    • Vymazal, J.1    Hajek, M.2    Patronas, N.3    Giedd, J.N.4    Bulte, J.W.M.5    Brooks, R.A.6
  • 30
    • 0013781121 scopus 로고
    • Determination of iron in heme compounds. 2. Hemoglobin and myoglobin
    • B. F. Cameron, Determination of iron in heme compounds. 2. Hemoglobin and myoglobin. Anal. Biochem. 11, 164-169 (1985).
    • (1985) Anal. Biochem. , vol.11 , pp. 164-169
    • Cameron, B.F.1
  • 32
    • 0028946290 scopus 로고
    • Permeation of small molecules into the cavity of ferritin as revealed by proton nuclear magnetic resonance relaxation
    • D. Yang, K. Nagayama, Permeation of small molecules into the cavity of ferritin as revealed by proton nuclear magnetic resonance relaxation. Biochem. J. 307, 253-256 (1995).
    • (1995) Biochem. J. , vol.307 , pp. 253-256
    • Yang, D.1    Nagayama, K.2
  • 33
    • 0004690906 scopus 로고    scopus 로고
    • Longitudinal relaxation of water protons in colloidal suspensions of superparamagnetic crystals
    • A. Roch, R. N. Muller, Longitudinal relaxation of water protons in colloidal suspensions of superparamagnetic crystals, in "Proc., SMRM, 11th Annual Meeting, Berlin, 1992," p. 1447.
    • Proc., SMRM, 11th Annual Meeting, Berlin, 1992 , pp. 1447
    • Roch, A.1    Muller, R.N.2
  • 34
    • 0000803940 scopus 로고
    • Ferritin III. The magnetic properties of ferritin and some other colloidal ferric compounds
    • L. Michaelis, C. D. Coryell, S. Granick, Ferritin III. The magnetic properties of ferritin and some other colloidal ferric compounds. J. Biol. Chem. 148, 463-480 (1943).
    • (1943) J. Biol. Chem. , vol.148 , pp. 463-480
    • Michaelis, L.1    Coryell, C.D.2    Granick, S.3
  • 35
    • 7344231027 scopus 로고
    • Observation par mesures magnétique et effet Mossbauer d'un antiferromagnétisme de grains fins dans la ferritine
    • Groupe 5
    • A. Blaise, J. Chappert, J. -L. Girardet, Observation par mesures magnétique et effet Mossbauer d'un antiferromagnétisme de grains fins dans la ferritine. C. R. Acad. Sci. III 261(Groupe 5), 2310-2313 (1965).
    • (1965) C. R. Acad. Sci. III , vol.261 , pp. 2310-2313
    • Blaise, A.1    Chappert, J.2    Girardet, J.L.3
  • 36
    • 0008844466 scopus 로고
    • Superparamagnétisme des grains très fins antiferromagnétiques
    • L. Néel, Superparamagnétisme des grains très fins antiferromagnétiques. C. R. Acad. Sci. III 252, 4075-4080 (1961).
    • (1961) C. R. Acad. Sci. III , vol.252 , pp. 4075-4080
    • Néel, L.1
  • 37
    • 36849127400 scopus 로고
    • Nuclear magnetic resonance study of tho protolysis of trimethylammonium ion in aqueous solution - Order of the reaction with respect to solvent
    • Z. Luz, S. Meiboom, Nuclear magnetic resonance study of tho protolysis of trimethylammonium ion in aqueous solution - order of the reaction with respect to solvent. J. Chem. Phys. 39, 366-370 (1963).
    • (1963) J. Chem. Phys. , vol.39 , pp. 366-370
    • Luz, Z.1    Meiboom, S.2
  • 38
    • 0020073799 scopus 로고
    • Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field
    • K. R. Thulborn, J. C. Waterton, P. M. Matthews, G. K. Radda, Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim. Biophys. Acta 714, 265-270 (1982).
    • (1982) Biochim. Biophys. Acta , vol.714 , pp. 265-270
    • Thulborn, K.R.1    Waterton, J.C.2    Matthews, P.M.3    Radda, G.K.4
  • 39
    • 0023588185 scopus 로고
    • Magnetic resonance imaging of stationary blood: A review
    • R. A. Brooks, G. Di Chiro, Magnetic resonance imaging of stationary blood: a review. Med. Phys. 14, 903-913 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 903-913
    • Brooks, R.A.1    Di Chiro, G.2
  • 40
    • 0023854359 scopus 로고
    • MR relaxation times and iron content of thalassemic spleens: An in vitro study
    • J. M. Gomori, R. I. Grossman, H. R. Drott, MR relaxation times and iron content of thalassemic spleens: an in vitro study. Am. J. Roentgenol. 150, 567-569 (1988).
    • (1988) Am. J. Roentgenol. , vol.150 , pp. 567-569
    • Gomori, J.M.1    Grossman, R.I.2    Drott, H.R.3
  • 41
    • 0024323153 scopus 로고
    • The influence of pulse sequence on the relaxation effects of superparamagnetic iron oxide contrast agents
    • S. Majumdar, S. S. Zoghbi, J. C. Gore, The influence of pulse sequence on the relaxation effects of superparamagnetic iron oxide contrast agents. Magn. Reson. Mad. 10, 289-301 (1989).
    • (1989) Magn. Reson. Mad. , vol.10 , pp. 289-301
    • Majumdar, S.1    Zoghbi, S.S.2    Gore, J.C.3
  • 42
    • 0028998624 scopus 로고
    • Increased iron-related MRI contrast in the substantia nigra in Parkinson's disease
    • J. M. Gorell, R. J. Ordidge, G. G. Brown, J. -C. Deniau, N. M. Buderer, J. A. Helpern, Increased iron-related MRI contrast in the substantia nigra in Parkinson's disease. Neurology 45, 1138-1143 (1995).
    • (1995) Neurology , vol.45 , pp. 1138-1143
    • Gorell, J.M.1    Ordidge, R.J.2    Brown, G.G.3    Deniau, J.C.4    Buderer, N.M.5    Helpern, J.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.