메뉴 건너뛰기




Volumn 14, Issue 1, 1996, Pages 103-114

In vivo pO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field

Author keywords

F 19 NMR; Fluorine 19 magnetic resonance imaging (MRI); Liver; Lung; Oxygen imaging; Perfluorocarbon F 19 NMR; pO2 imaging; Spleen

Indexed keywords

FLUOROCARBON; PERFLUOROTRIBUTYLAMINE; POLOXAMER; BLOOD SUBSTITUTE; OXYGEN;

EID: 0029665210     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/0730-725X(95)02046-V     Document Type: Article
Times cited : (35)

References (37)
  • 1
    • 85030194110 scopus 로고    scopus 로고
    • Alpha Therapeutic Corporation, 5555 Valley Blvd., Los Angeles, CA 92121 (Distributor) and Green Cross Corporation, Osaka, 932-1201 1/3, Camon-Cho, Joto-ku, Japan (Manufacturer). (Products: Fluosol-DA and Oxypherol-ET.)
    • Alpha Therapeutic Corporation, 5555 Valley Blvd., Los Angeles, CA 92121 (Distributor) and Green Cross Corporation, Osaka, 932-1201 1/3, Camon-Cho, Joto-ku, Japan (Manufacturer). (Products: Fluosol-DA and Oxypherol-ET.)
  • 2
    • 85030190731 scopus 로고    scopus 로고
    • Alliance Pharmaceutical Corp., 3040 Science Park Road, San Diego, CA 92121. (Product: Oxygent-HT.)
    • Alliance Pharmaceutical Corp., 3040 Science Park Road, San Diego, CA 92121. (Product: Oxygent-HT.)
  • 3
    • 85030195291 scopus 로고    scopus 로고
    • HemaGen/PFC. 11810 Borman Drive, St. Louis, MO 63146
    • HemaGen/PFC. 11810 Borman Drive, St. Louis, MO 63146.
  • 4
    • 0011628249 scopus 로고
    • Perfluorochemical emulsions as blood substitutes
    • J. Sjoblom (Ed). The Netherlands: Kluwer Academic Publishers
    • Kaufman, R.J. Perfluorochemical emulsions as blood substitutes. In: J. Sjoblom (Ed). Emulsions - A Fundamental and Practical Approach. The Netherlands: Kluwer Academic Publishers; 1992: pp. 207-226.
    • (1992) Emulsions - A Fundamental and Practical Approach , pp. 207-226
    • Kaufman, R.J.1
  • 5
    • 0028434245 scopus 로고
    • The design and development of improved fluorocarbon-based products for use in medicine and biology
    • Riess, J.G. The design and development of improved fluorocarbon-based products for use in medicine and biology. Art. Cells Blood Subs Immob. Biotechnol. 22: 215-254; 1994.
    • (1994) Art. Cells Blood Subs Immob. Biotechnol. , vol.22 , pp. 215-254
    • Riess, J.G.1
  • 6
    • 0026761155 scopus 로고
    • Overview of progress in the fluorocarbon approach to in vivo oxygen delivery
    • Riess, J.G. Overview of progress in the fluorocarbon approach to in vivo oxygen delivery. Biomat. Art. Cells Immob. Biotechnol. 20(2-4): 183-202; 1992.
    • (1992) Biomat. Art. Cells Immob. Biotechnol. , vol.20 , Issue.2-4 , pp. 183-202
    • Riess, J.G.1
  • 7
    • 0003025689 scopus 로고
    • The solubility of oxygen in highly fluoridated liquids
    • Wessler, E.P.; Iltis, R.; Clark, L.C., Jr. The solubility of oxygen in highly fluoridated liquids. J. Fluor. Chem. 9:137-146; 1977.
    • (1977) J. Fluor. Chem. , vol.9 , pp. 137-146
    • Wessler, E.P.1    Iltis, R.2    Clark L.C., Jr.3
  • 8
    • 0002224867 scopus 로고
    • The biomedical applications of fluorine-19 NMR
    • C.L. Partain, R.R. Price, J.A. Patton, et al. (Eds). Philadelphia: W.b. Saunders
    • Thomas, S.R. The biomedical applications of fluorine-19 NMR. In: C.L. Partain, R.R. Price, J.A. Patton, et al. (Eds). Magnetic Resonance Imaging, Second Edition, Vol. II: Physical Principles and Instrumentation. Philadelphia: W.B. Saunders; 1988: pp. 1536-1552.
    • (1988) Magnetic Resonance Imaging, Second Edition, Vol. II: Physical Principles and Instrumentation , vol.2 , pp. 1536-1552
    • Thomas, S.R.1
  • 11
    • 0023162430 scopus 로고
    • Oxygen-sensitive F-19 NMR imaging of the vascular system in vivo
    • Fishman, J.E.; Joseph, P.M.; Floyd, T.F.; et al. Oxygen-sensitive F-19 NMR imaging of the vascular system in vivo. Magn. Reson. Imaging 5:279-285; 1987.
    • (1987) Magn. Reson. Imaging , vol.5 , pp. 279-285
    • Fishman, J.E.1    Joseph, P.M.2    Floyd, T.F.3
  • 12
    • 0026800866 scopus 로고
    • A noninvasive assessment of myocardial oxygen tension: 19F NMR spectroscopy of sequestered perfluorocarbon emulsion
    • Mason, R.P.; Jeffrey, F.M.H.; Malloy, C.R.; Babcock, E.E.; Antich, P.P. A noninvasive assessment of myocardial oxygen tension: 19F NMR spectroscopy of sequestered perfluorocarbon emulsion. Magn. Reson. Med. 27:310-317; 1992.
    • (1992) Magn. Reson. Med. , vol.27 , pp. 310-317
    • Mason, R.P.1    Jeffrey, F.M.H.2    Malloy, C.R.3    Babcock, E.E.4    Antich, P.P.5
  • 14
    • 0026687585 scopus 로고
    • Measurement of preretinal oxygen tension in vitrectomized human eye using fluorine-19 magnetic resonance spectroscopy
    • Wilson, C.A.; Berkowitz, B.A.; McCuen, B.W., II; Charles, H.C. Measurement of preretinal oxygen tension in vitrectomized human eye using fluorine-19 magnetic resonance spectroscopy. Arch. Ophthalmol. 110:1098-1100; 1992.
    • (1992) Arch. Ophthalmol. , vol.110 , pp. 1098-1100
    • Wilson, C.A.1    Berkowitz, B.A.2    McCuen B.W. II3    Charles, H.C.4
  • 15
    • 0027534422 scopus 로고
    • In vivo oxygen tension and temperature: Simultaneous determination using 19F NMR spectroscopy of perfluorocarbon
    • Mason, R.P.; Shukla, H.; Antich, P.P. In vivo oxygen tension and temperature: Simultaneous determination using 19F NMR spectroscopy of perfluorocarbon. Magn. Reson. Med. 29:296-302; 1993.
    • (1993) Magn. Reson. Med. , vol.29 , pp. 296-302
    • Mason, R.P.1    Shukla, H.2    Antich, P.P.3
  • 17
    • 0001688338 scopus 로고
    • Fluorine-19 relaxation study of perfluoro chemicals as oxygen carriers
    • Parhami, P.; Fung, B.M. Fluorine-19 relaxation study of perfluoro chemicals as oxygen carriers. J. Phys. Chem. 87:1928-1931; 1983.
    • (1983) J. Phys. Chem. , vol.87 , pp. 1928-1931
    • Parhami, P.1    Fung, B.M.2
  • 18
    • 0004427862 scopus 로고
    • Effect of oxygen and the lipid spin label TEMPO-laurate on fluorine-19 and proton relaxation rates of the perfluorochemical blood substitute, FC-43 emulsion
    • Lai, C.S.; Stair, S.J.; Miziorko, H.; Hyde, J.S. Effect of oxygen and the lipid spin label TEMPO-laurate on fluorine-19 and proton relaxation rates of the perfluorochemical blood substitute, FC-43 emulsion. J. Magn. Reson. 57:447-452; 1984.
    • (1984) J. Magn. Reson. , vol.57 , pp. 447-452
    • Lai, C.S.1    Stair, S.J.2    Miziorko, H.3    Hyde, J.S.4
  • 21
    • 0343972010 scopus 로고
    • Potential uses of perfluorochemical artificial blood for experimental studies in physiology, biology, biochemistry, chemotherapy, toxicology, metabolism, etc. FC-43 emulsion
    • September 4
    • The Green Cross Corporation. Potential uses of perfluorochemical artificial blood for experimental studies in physiology, biology, biochemistry, chemotherapy, toxicology, metabolism, etc. FC-43 emulsion. Technical Information Series No. 3, September 4, 1976.
    • (1976) Technical Information Series No. 3 , vol.3
  • 22
    • 0016318706 scopus 로고
    • Determination of particle size distribution of fluorocarbon emulsion by means of centrifugal sedimentation
    • Tokyo
    • Yokoyama, K.; Suzuki, A.; Utsumi, I.; Naito, R. Determination of particle size distribution of fluorocarbon emulsion by means of centrifugal sedimentation. Chem. Pharm. Bull. (Tokyo) 22:2966-2971; 1974.
    • (1974) Chem. Pharm. Bull. , vol.22 , pp. 2966-2971
    • Yokoyama, K.1    Suzuki, A.2    Utsumi, I.3    Naito, R.4
  • 25
    • 0021740419 scopus 로고
    • Practical aspects involved in the design and set up of a 0.15T, 6-coil resistive magnet, whole body NMR imaging facility
    • Thomas, S.R.; Ackerman, J.L.; Kereiakes, J.G. Practical aspects involved in the design and set up of a 0.15T, 6-coil resistive magnet, whole body NMR imaging facility. Magn. Reson. Imaging 2:341-348; 1984.
    • (1984) Magn. Reson. Imaging , vol.2 , pp. 341-348
    • Thomas, S.R.1    Ackerman, J.L.2    Kereiakes, J.G.3
  • 26
    • 0023888567 scopus 로고
    • Resonator coils for magnetic resonance imaging at 6 MHz
    • Samaratunga, R.C.; Busse, L.J.; Pratt, R.G.; Thomas, S.R. Resonator coils for magnetic resonance imaging at 6 MHz. Med. Phys. 15(2):235-240; 1988.
    • (1988) Med. Phys. , vol.15 , Issue.2 , pp. 235-240
    • Samaratunga, R.C.1    Busse, L.J.2    Pratt, R.G.3    Thomas, S.R.4
  • 28
    • 0020636464 scopus 로고
    • Measurement of spin-lattice relaxation times in nuclear magnetic resonance imaging
    • Pykett, I.L.; Rosen, B.R.; Buonanno, F.S.; Brady, T.J. Measurement of spin-lattice relaxation times in nuclear magnetic resonance imaging. Phys. Med. Biol. 28:723-729; 1983.
    • (1983) Phys. Med. Biol. , vol.28 , pp. 723-729
    • Pykett, I.L.1    Rosen, B.R.2    Buonanno, F.S.3    Brady, T.J.4
  • 30
    • 85030189955 scopus 로고    scopus 로고
    • Doctoral dissertation (Ph.D. thesis, unpublished). Department of Physics, University of Cincinnati, Cincinnati, OH 45220-0011
    • 2) using F-19 in nuclear magnetic resonance (NMR) imaging. Doctoral dissertation (Ph.D. thesis, unpublished). Department of Physics, University of Cincinnati, Cincinnati, OH 45220-0011.
    • 2) Using F-19 in Nuclear Magnetic Resonance (NMR) Imaging
    • Tan, K.K.1
  • 32
    • 0002321597 scopus 로고
    • Design, synthesis and evaluation of fluorocarbons and surfactants for in vivo applications: New perfluoroalkylated polyhydroxylated surfactants
    • R.M.S. Chang, R.P. Geyer (Eds). New York: Marcel Dek-ker, Inc.
    • Reiss, J.G.; Arlen, C.; Greiner, J.; Le Blanc, M.; Manfredi, A.; Pace, C.; Varescon, C.; Zarif, L. Design, synthesis and evaluation of fluorocarbons and surfactants for in vivo applications: New perfluoroalkylated polyhydroxylated surfactants. In: R.M.S. Chang, R.P. Geyer (Eds). Blood Substitutes. New York: Marcel Dek-ker, Inc.; 1989: pp. 421-430.
    • (1989) Blood Substitutes , pp. 421-430
    • Reiss, J.G.1    Arlen, C.2    Greiner, J.3    Le Blanc, M.4    Manfredi, A.5    Pace, C.6    Varescon, C.7    Zarif, L.8
  • 33
    • 0343536077 scopus 로고
    • Alveolar ventilation
    • Chicago: Yearbook Medical Publishers, Inc.
    • Comroe, J.M., Jr. Alveolar ventilation. In: Physiology of Respiration, 2nd ed. Chicago: Yearbook Medical Publishers, Inc.; 1974: pp. 8-21.
    • (1974) Physiology of Respiration, 2nd Ed. , pp. 8-21
    • Comroe J.M., Jr.1
  • 34
    • 0026635496 scopus 로고
    • Spatial correlation of regional pulmonary perfusion
    • Glenny, R. W. Spatial correlation of regional pulmonary perfusion. J. Appl. Physiol. 72(6):2378-2386; 1992.
    • (1992) J. Appl. Physiol. , vol.72 , Issue.6 , pp. 2378-2386
    • Glenny, R.W.1
  • 35
    • 0021165066 scopus 로고
    • Perfluorochemicals: Morphologic changes in infused liver, spleen, lung, and kidney of rabbits
    • Nanney, L.; Fink, L.M. and Virmani, R. Perfluorochemicals: Morphologic changes in infused liver, spleen, lung, and kidney of rabbits. Arch. Pathol. Lab. Med. 108: 631-637; 1984.
    • (1984) Arch. Pathol. Lab. Med. , vol.108 , pp. 631-637
    • Nanney, L.1    Fink, L.M.2    Virmani, R.3
  • 36
    • 0002158779 scopus 로고
    • 2-supply of the liver
    • D.W. Lübbers, et al. (Eds). Stuttgart: George Thiem Verlag
    • 2-supply of the liver. In: D.W. Lübbers, et al. (Eds). Oxygen Transport in Blood and Tissue. Stuttgart: George Thiem Verlag; 1968: pp. 242-251.
    • (1968) Oxygen Transport in Blood and Tissue , pp. 242-251
    • Kessler, M.1
  • 37
    • 0342665874 scopus 로고
    • The end of a postulate: There are no hostile metabolic conditions within the normal spleen
    • Karger, Basel
    • Vaupel, P.; Frinak, S.; Müller-Klieser, W.; Manz, R. The end of a postulate: There are no hostile metabolic conditions within the normal spleen. Biblthca. Anat., No. 209:403-406 (Karger, Basel); 1981.
    • (1981) Biblthca. Anat. , vol.209 , pp. 403-406
    • Vaupel, P.1    Frinak, S.2    Müller-Klieser, W.3    Manz, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.