메뉴 건너뛰기




Volumn 42, Issue 5, 1995, Pages 1483-1488

Approximate Reconstruction of Attenuation Map in SPECT Imaging

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; APPROXIMATION THEORY; DATA PROCESSING; ELECTROMAGNETIC WAVE ATTENUATION; IMAGE RECONSTRUCTION; INVERSE PROBLEMS; MATHEMATICAL MODELS; MATHEMATICAL TRANSFORMATIONS; MEDICAL IMAGING; NONDESTRUCTIVE EXAMINATION; NUCLEAR MEDICINE; NUMERICAL METHODS;

EID: 0029388057     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.467945     Document Type: Article
Times cited : (44)

References (29)
  • 2
    • 0026138703 scopus 로고
    • Activity quantitation in SPECT: A comparison of three attenuation correction methods in combination with pre-reconstruction restoration filtering
    • M. A. King, S. J. Glick, and B. C. Penney, “Activity quantitation in SPECT: A comparison of three attenuation correction methods in combination with pre-reconstruction restoration filtering,” IEEE Trans. Nucl. Sci., vol. 38, pp. 755–760, 1991.
    • (1991) IEEE Trans. Nucl. Sci. , vol.38 , pp. 755-760
    • King, M.A.1    Glick, S.J.2    Penney, B.C.3
  • 5
    • 0027429814 scopus 로고
    • A scanning line source for simultaneous emission and transmission measurements in SPECT
    • P. Tan, D. L. Bailey, S. R. Merke, S. Ebert, R. R. Fulton, and B. F. Hutton, “A scanning line source for simultaneous emission and transmission measurements in SPECT,” J. Nucl. Med., vol. 34, pp. 1752–1760, 1993.
    • (1993) J. Nucl. Med. , vol.34 , pp. 1752-1760
    • Tan, P.1    Bailey, D.L.2    Merke, S.R.3    Ebert, S.4    Fulton, R.R.5    Hutton, B.F.6
  • 6
    • 0026460467 scopus 로고
    • Simultaneous acquisition of emission and transmission data for improved thallium-201 cardiac SPECT imaging using a technetium-99m transmission source
    • E. C. Frey, B. M. W. Tsui, and J. R. Perry, “Simultaneous acquisition of emission and transmission data for improved thallium-201 cardiac SPECT imaging using a technetium-99m transmission source,” J. Nucl. Med., vol. 33, pp. 2238–2245, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 2238-2245
    • Frey, E.C.1    Tsui, B.M.W.2    Perry, J.R.3
  • 7
    • 0028711780 scopus 로고
    • Investigation of the use of X-ray CT images for attenuation compensation in SPECT
    • K. J. LaCroix, B. M. W. Tsui, B. H. Hasegawa, and J. K. Brown, “Investigation of the use of X-ray CT images for attenuation compensation in SPECT,” IEEE Trans. Nucl. Sci., vol. 41, pp. 2793–2799, 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 2793-2799
    • LaCroix, K.J.1    Tsui, B.M.W.2    Hasegawa, B.H.3    Brown, J.K.4
  • 8
    • 0028493664 scopus 로고
    • Using simultaneous transmission and scatter SPECT imaging from external sources for the determination of the thoratic μ-map
    • S. Locaric, W. Chang, and G. Huang, “Using simultaneous transmission and scatter SPECT imaging from external sources for the determination of the thoratic μ-map,” IEEE Trans. Nucl. Sci., vol. 41, pp. 1601–1606, 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 1601-1606
    • Locaric, S.1    Chang, W.2    Huang, G.3
  • 9
    • 0026902682 scopus 로고
    • Non-uniform attenuation correction using simultaneous transmission and emission converging tomography
    • C.-H Tung, G. T. Gullberg G. T., G. L. Zeng, P. E. Christian, F. L. Datz, and H. T. Morgan, “Non-uniform attenuation correction using simultaneous transmission and emission converging tomography,” IEEE Trans. Nucl. Sci., vol. 39, pp. 1134–1143, 1992.
    • (1992) IEEE Trans. Nucl. Sci. , vol.39 , pp. 1134-1143
    • Tung, C.-H.1    Gullberg, G.T.2    Zeng, G.L.3    Christian, P.E.4    Datz, F.L.5    Morgan, H.T.6
  • 11
    • 0026982073 scopus 로고
    • A radioactivity assay method using computed tomography
    • T. Goto and H. Kato, “A radioactivity assay method using computed tomography,” Nucl. Technol., vol. 100, pp. 322–330, 1992.
    • (1992) Nucl. Technol. , vol.100 , pp. 322-330
    • Goto, T.1    Kato, H.2
  • 12
  • 13
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • L. T. Chang, “A method for attenuation correction in radionuclide computed tomography,” IEEE Trans. Nucl. Sci., vol. NS-25, pp. 638–643, 1978.
    • (1978) IEEE Trans. Nucl. Sci. , vol.NS-25 , pp. 638-643
    • Chang, L.T.1
  • 15
    • 0001197863 scopus 로고
    • The exponential Radon transform
    • O. Tretiak and C. Metz, “The exponential Radon transform,” SIAM J. Appl. Math., vol. 39, pp. 342–354, 1980.
    • (1980) SIAM J. Appl. Math. , vol.39 , pp. 342-354
    • Tretiak, O.1    Metz, C.2
  • 16
    • 0025256947 scopus 로고
    • Attenuation correction in SPECT based on transmission studies and Monte-Carlo simulations of build-up functions
    • M. Ljundberg and S. Strand, “Attenuation correction in SPECT based on transmission studies and Monte-Carlo simulations of build-up functions,” J. Nucl. Med., vol. 31, pp. 493–500, 1990.
    • (1990) J. Nucl. Med. , vol.31 , pp. 493-500
    • Ljundberg, M.1    Strand, S.2
  • 17
    • 0346390664 scopus 로고
    • Single-photon emission computed tomography by inverting the attenuated Radon transform with least-squares collocation
    • U. Heike, “Single-photon emission computed tomography by inverting the attenuated Radon transform with least-squares collocation,” Inverse Problems, vol. 2, pp. 307–330, 1986.
    • (1986) Inverse Problems , vol.2 , pp. 307-330
    • Heike, U.1
  • 18
    • 0343320131 scopus 로고
    • Generalized and attenuated Radon transforms: restorative approach to the numerical inversion
    • L. Kunyansky, “Generalized and attenuated Radon transforms: restorative approach to the numerical inversion,” Inverse Problems, vol. 8, pp. 809–819, 1992.
    • (1992) Inverse Problems , vol.8 , pp. 809-819
    • Kunyansky, L.1
  • 19
    • 84937077431 scopus 로고
    • An approach for reduction of attenuation artifacts from using the emission data in SPECT TL-201 cardiac perfusion imaging
    • T. S. Pan, D. W. Seldin, S. T. Dahlberg, and M. A. King, “An approach for reduction of attenuation artifacts from using the emission data in SPECT TL-201 cardiac perfusion imaging,” J. Nucl. Med., vol. 35, p. 82, 1994.
    • (1994) J. Nucl. Med. , vol.35 , pp. 82
    • Pan, T.S.1    Seldin, D.W.2    Dahlberg, S.T.3    King, M.A.4
  • 20
    • 0020831361 scopus 로고
    • Computerized tomography with unknown sources
    • F. Natterer, “Computerized tomography with unknown sources,” SIAM J. Appl. Math., vol. 43, pp. 1201–1202, 1983.
    • (1983) SIAM J. Appl. Math. , vol.43 , pp. 1201-1202
    • Natterer, F.1
  • 21
    • 0001591547 scopus 로고
    • Determination of tissue attenuation in emission tomography of optically dense media
    • F. Natterer, “Determination of tissue attenuation in emission tomography of optically dense media,” Inverse Problems, vol. 9, pp. 731–736, 1993.
    • (1993) Inverse Problems , vol.9 , pp. 731-736
    • Natterer, F.1
  • 22
    • 0018457105 scopus 로고
    • A new approach to the emission computerized tomography problem:simultaneous calculation of attenuation and activity coefficients
    • Y. D. Censor, A. Gustafson, A. Lent, and H. Tuy, “A new approach to the emission computerized tomography problem:simultaneous calculation of attenuation and activity coefficients,” IEEE Trans. Nucl. Sci., vol. NS-26, pp. 2275–2779, 1979.
    • (1979) IEEE Trans. Nucl. Sci. , vol.NS-26 , pp. 2275-2779
    • Censor, Y.D.1    Gustafson, A.2    Lent, A.3    Tuy, H.4
  • 23
    • 0023593641 scopus 로고
    • Attenuation correction method for single-photon emission CT without any additional data collection
    • R. Kusaba, M. Nakajima, K. Ogawa, S. Yuta, and T. Morozumi, “Attenuation correction method for single-photon emission CT without any additional data collection,” Syst. and Compute. in Japan, vol. 18, pp. 64–71, 1987.
    • (1987) Syst. and Compute. in Japan , vol.18 , pp. 64-71
    • Kusaba, R.1    Nakajima, M.2    Ogawa, K.3    Yuta, S.4    Morozumi, T.5
  • 24
    • 0346390663 scopus 로고    scopus 로고
    • Maximum entropy method in emission tomography of semitransparent media
    • A. V. Bronnikov and N. G. Preobrazhenskii, “Maximum entropy method in emission tomography of semitransparent media,” Sov. Phys. Dokl., vol. 36, no. 1, pp. 64–66.
    • Sov. Phys. Dokl. , vol.36 , Issue.1 , pp. 64-66
    • Bronnikov, A.V.1    Preobrazhenskii, N.G.2
  • 25
    • 0346390666 scopus 로고
    • Emission tomography of self-absorptive sources of radiation
    • A. V. Bronnikov, “Emission tomography of self-absorptive sources of radiation,” Sov. Phys. Dokl., vol. 37, no. 2, pp. 76–78, 1992.
    • (1992) Sov. Phys. Dokl. , vol.37 , Issue.2 , pp. 76-78
    • Bronnikov, A.V.1
  • 26
    • 38149146626 scopus 로고
    • Degradation transfrom in tomography
    • A. V. Bronnikov, “Degradation transfrom in tomography,” Patt. Recogn. Lett., vol. 15, pp. 527–532, 1994.
    • (1994) Patt. Recogn. Lett. , vol.15 , pp. 527-532
    • Bronnikov, A.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.