-
2
-
-
0026900633
-
An improved multicrystal 2-D BGO detector for PET
-
J. G. Rogers, A. J. Taylor, M. F. Rahimi, R. Nutt, M. Andreaco and C. W. Williams, “An improved multicrystal 2-D BGO detector for PET”, IEEE Trans. Nucl. Sci., NS-39 1063 (1992).
-
(1992)
IEEE Trans. Nucl. Sci.
, vol.NS-39
, pp. 1063
-
-
Rogers, J.G.1
Taylor, A.J.2
Rahimi, M.F.3
Nutt, R.4
Andreaco, M.5
Williams, C.W.6
-
3
-
-
0028494061
-
Testing 144- and 256-crystal BGO block detectors
-
J. G. Rogers, R. Nutt, M. Andreaco and C. W. Williams, “Testing 144- and 256-crystal BGO block detectors”, IEEE Trans. Nucl. Sci., NS-41 1423 (1994).
-
(1994)
IEEE Trans. Nucl. Sci.
, vol.NS-41
, pp. 1423
-
-
Rogers, J.G.1
Nutt, R.2
Andreaco, M.3
Williams, C.W.4
-
4
-
-
0028494319
-
Design studies for a PET detector module using a PIN photodiode to measure depth of interaction
-
W. W. Moses and S. E. Derenzo, “Design studies for a PET detector module using a PIN photodiode to measure depth of interaction.”, IEEE Trans. Nucl. Sci., NS-41 1441 (1994).
-
(1994)
IEEE Trans. Nucl. Sci.
, vol.NS-41
, pp. 1441
-
-
Moses, W.W.1
Derenzo, S.E.2
-
5
-
-
0026505930
-
PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems
-
C. J. Thompson, J. Moreno-Cantu and Y. Picard, “PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems”, Phys. Med. Biol., 37, No. 3, 731 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, Issue.3
, pp. 731
-
-
Thompson, C.J.1
Moreno-Cantu, J.2
Picard, Y.3
-
6
-
-
0037699925
-
A new algorithm for using Depth-of-Interaction measurement information in PET data acquisition
-
W. W. Moses, R. H. Huesman and S. E. Derenzo, “A new algorithm for using Depth-of-Interaction measurement information in PET data acquisition”, J. Nucl. Med., 32 995 (1991).
-
(1991)
J. Nucl. Med.
, vol.32
, pp. 995
-
-
Moses, W.W.1
Huesman, R.H.2
Derenzo, S.E.3
-
7
-
-
0005891197
-
Three-dimensional image reconstruction in object space
-
P. E. Kinahan, J. G. Rogers, R. Harrop, and R. R. Johnson, “Three-dimensional image reconstruction in object space”, IEEE Trans. Nucl. Sci., NS-35 635 (1988).
-
(1988)
IEEE Trans. Nucl. Sci.
, vol.NS-35
, pp. 635
-
-
Kinahan, P.E.1
Rogers, J.G.2
Harrop, R.3
Johnson, R.R.4
-
8
-
-
0026710516
-
Physical performance of a positron tomograph for brain imaging with retractable septa
-
T. J. Spinks, T. Jones, D. L. Bailey, D. W. Townsend, S. Grootoonk, P. M. Bloomfield, M.-C. Gilardi, M. E. Casey. B. Sipe and J. Reed, “Physical performance of a positron tomograph for brain imaging with retractable septa”, Phys. Med. Biol., 37, No. 8, 1637 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, Issue.8
, pp. 1637
-
-
Spinks, T.J.1
Jones, T.2
Bailey, D.L.3
Townsend, D.W.4
Grootoonk, S.5
Bloomfield, P.M.6
Gilardi, M.-C.7
Casey, M.E.8
Sipe, B.9
Reed, J.10
-
9
-
-
0028184998
-
Investigating the effect of angular mashing of PET sinogram data on reconstructed images
-
H. P. Gadagkar and M. E. Casey, “Investigating the effect of angular mashing of PET sinogram data on reconstructed images”, 1993 IEEE MIC Conference Record, Vol. 2, 1213–1216 (1993).
-
(1993)
1993 IEEE MIC Conference Record
, vol.2
, pp. 1213-1216
-
-
Gadagkar, H.P.1
Casey, M.E.2
-
10
-
-
0027644025
-
Optimization of PET instrumentation for brain activation studies
-
M. Dahlbom, S. R. Cherry, L. Eriksson, E. J. Hoffman, K. Weinhard, “Optimization of PET instrumentation for brain activation studies”, IEEE Trans. Nucl. Sci., NS-40 1048 (1993).
-
(1993)
IEEE Trans. Nucl. Sci.
, vol.NS-40
, pp. 1048
-
-
Dahlbom, M.1
Cherry, S.R.2
Eriksson, L.3
Hoffman, E.J.4
Weinhard, K.5
|