메뉴 건너뛰기




Volumn 42, Issue 4, 1995, Pages 1223-1227

A System for the 3D Reconstruction of Retracted-Septa PET Data Using the EM Algorithm

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MATHEMATICAL MODELS; OPTICAL DATA PROCESSING; PARALLEL ALGORITHMS; PARALLEL PROCESSING SYSTEMS; PROBLEM SOLVING; TABLE LOOKUP; THREE DIMENSIONAL;

EID: 0029359456     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.467875     Document Type: Article
Times cited : (65)

References (11)
  • 1
    • 0021327145 scopus 로고
    • EM Reconstruction Algorithms for Emission and Transmission Tomography
    • Lange, K., and Carson, R., “EM Reconstruction Algorithms for Emission and Transmission Tomography,” J. Comp. Assist. Tomogr., vol. 8, pp. 306–316, 1984.
    • (1984) J. Comp. Assist. Tomogr. , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 2
    • 0028496882 scopus 로고
    • Precision and Accuracy of Regional Radioactivity Quantitation Using the Maximum Likelihood EM Reconstruction Algorithm
    • Carson, R. E., Yan, Y., Chodkowski, B., Yap, T. K. and Daube-Witherspoon, M. E., “Precision and Accuracy of Regional Radioactivity Quantitation Using the Maximum Likelihood EM Reconstruction Algorithm,” IEEE Trans. Med. Imag., vol. 13, pp. 526–537, 1994.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 526-537
    • Carson, R.E.1    Yan, Y.2    Chodkowski, B.3    Yap, T.K.4    Daube-Witherspoon, M.E.5
  • 3
    • 0025780950 scopus 로고
    • 3D PET using a Conventional Multislice Tomograph without Septa
    • Cherry, S. R., Dahlbom, M., and Hoffman, E., “3D PET using a Conventional Multislice Tomograph without Septa,” J. Comp. Assist. Tomogr., vol. 15, pp. 655–668, 1991.
    • (1991) J. Comp. Assist. Tomogr. , vol.15 , pp. 655-668
    • Cherry, S.R.1    Dahlbom, M.2    Hoffman, E.3
  • 4
    • 0023314408 scopus 로고
    • Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
    • Kaufman, L., “Implementing and Accelerating the EM Algorithm for Positron Emission Tomography,” IEEE Trans. Med. Imag., vol. MI-6, pp. 37–51, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.MI-6 , pp. 37-51
    • Kaufman, L.1
  • 5
    • 0007552281 scopus 로고
    • Solving Emission Tomography Problems on Vector Machines
    • Kaufman, L., “Solving Emission Tomography Problems on Vector Machines,” Ann. Oper. Res., vol. 22, pp. 325–353, 1990.
    • (1990) Ann. Oper. Res. , vol.22 , pp. 325-353
    • Kaufman, L.1
  • 6
    • 0026392246 scopus 로고
    • Parallelization of the EM Algorithm for 3D PET Image Reconstruction
    • Chen, C. M., Lee, S. Y., and Cho, Z. H., “Parallelization of the EM Algorithm for 3D PET Image Reconstruction,” IEEE Trans. Med. Imag., vol. 10, pp. 513–522, 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , pp. 513-522
    • Chen, C.M.1    Lee, S.Y.2    Cho, Z.H.3
  • 7
    • 0028485175 scopus 로고
    • On Parallelizing the EM Algorithm for PET Image Reconstruction
    • Chen, C. M., and Lee, S. Y., “On Parallelizing the EM Algorithm for PET Image Reconstruction,” IEEE Trans. Parallel. Dist. Syst., vol. 5, pp. 860–873, 1994.
    • (1994) IEEE Trans. Parallel. Dist. Syst. , vol.5 , pp. 860-873
    • Chen, C.M.1    Lee, S.Y.2
  • 10
    • 0020194763 scopus 로고
    • Maximum Likelihood Reconstruction for Emission Tomography
    • Shepp, L. A. and Vardi, Y., “Maximum Likelihood Reconstruction for Emission Tomography,” IEEE Trans. Med. Imag., vol MI-1, pp. 113–122, 1982.
    • (1982) IEEE Trans. Med. Imag. , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.