1
-
-
84938166869
-
Mammographic PET (MAMPET): a dedicated imaging device for breast cancer applications
-
G. D. Hutchins, “Mammographic PET (MAMPET): a dedicated imaging device for breast cancer applications,” Grant proposal to The Whitaker Foundation, pp. 28, 1993.
-
(1993)
Grant proposal to The Whitaker Foundation
, pp. 28
-
-
Hutchins, G.D.1
-
2
-
-
0028231817
-
Feasibility study for positron emission mammography
-
C. J. Thompson, K. Murthy, I. N. Weinberg, et al., “Feasibility study for positron emission mammography,” Med. Phys., vol. 21, pp. 529–538, 1994.
-
(1994)
Med. Phys.
, vol.21
, pp. 529-538
-
-
Thompson, C.J.1
Murthy, K.2
Weinberg, I.N.3
-
3
-
-
0028494319
-
Design studies for a PET detector module using a PIN photodiode to measure depth of interaction
-
W. W. Moses and S. E. Derenzo, “Design studies for a PET detector module using a PIN photodiode to measure depth of interaction,” IEEE Trans. Nucl. Sci., vol. NS–41, pp. 1441–1445, 1994.
-
(1994)
IEEE Trans. Nucl. Sci.
, vol.NS–41
, pp. 1441-1445
-
-
Moses, W.W.1
Derenzo, S.E.2
-
4
-
-
0021375336
-
Temperature dependence of fluorescence decay time and emission spectrum of bismuth germanate
-
C. L. Melcher, J. S. Schweitzer, A. Liberman, et al., “Temperature dependence of fluorescence decay time and emission spectrum of bismuth germanate,” IEEE Trans. Nucl. Sci., vol. NS-32, pp. 529–532, 1985.
-
(1985)
IEEE Trans. Nucl. Sci.
, vol.NS-32
, pp. 529-532
-
-
Melcher, C.L.1
Schweitzer, J.S.2
Liberman, A.3
-
5
-
-
0026902676
-
Cerium-doped lutetium orthosilicate: A fast, efficient new scintillator
-
C. L. Melcher and J. S. Schweitzer, “Cerium-doped lutetium orthosilicate: A fast, efficient new scintillator,” IEEE Trans. Nucl. Sci., vol. NS-39, pp. 502–504, 1992.
-
(1992)
IEEE Trans. Nucl. Sci.
, vol.NS-39
, pp. 502-504
-
-
Melcher, C.L.1
Schweitzer, J.S.2
-
6
-
-
0028494002
-
A 16-channel charge sensitive amplifier IC for a PIN photodiode array based PET detector module
-
pp. (submitted for publication)
-
W. W. Moses, I. Kipnis, and M. H. Ho, “A 16-channel charge sensitive amplifier IC for a PIN photodiode array based PET detector module,” IEEE Trans. Nucl. Sci., vol. NS-41, pp. (submitted for publication), 1994.
-
(1994)
IEEE Trans. Nucl. Sci.
, vol.NS-41
-
-
Moses, W.W.1
Kipnis, I.2
Ho, M.H.3
-
7
-
-
0037699925
-
A new algorithm for using depth-of-interaction measurement information in PET data acquisition
-
W. W. Moses, R. H. Huesman, and S. E. Derenzo, “A new algorithm for using depth-of-interaction measurement information in PET data acquisition,” J. Nucl. Med., vol. 32, pp. 995, 1991.
-
(1991)
J. Nucl. Med.
, vol.32
, pp. 995
-
-
Moses, W.W.1
Huesman, R.H.2
Derenzo, S.E.3
-
8
-
-
0027644024
-
Performance of a PET detector module utilizing an array of silicon photodiodes to identify the crystal of interaction
-
W. W. Moses, S. E. Derenzo, R. Nutt, et al., “Performance of a PET detector module utilizing an array of silicon photodiodes to identify the crystal of interaction,” IEEE Trans. Nucl. Sci., vol. NS-40, pp. 1036–1040, 1993.
-
(1993)
IEEE Trans. Nucl. Sci.
, vol.NS-40
, pp. 1036-1040
-
-
Moses, W.W.1
Derenzo, S.E.2
Nutt, R.3
-
9
-
-
0029358750
-
Advantages and limitations of LSO scintillator in nuclear physics experiments
-
(submitted for publication)
-
T. Ludziejewski, K. Moszynska, M. Moszynski, et al., “Advantages and limitations of LSO scintillator in nuclear physics experiments,” IEEE Trans. Nucl. Sci., vol. NS–42 (submitted for publication), 1995.
-
(1995)
IEEE Trans. Nucl. Sci.
, vol.NS–42
-
-
Ludziejewski, T.1
Moszynska, K.2
Moszynski, M.3
-
10
-
-
0029358209
-
Feasibility study of an avalanche photodiode readout for a high resolution PET with nsec time resolution
-
(submitted for publication)
-
C. Schmelz, S. M. Bradbury, I. Holl, et al., “Feasibility study of an avalanche photodiode readout for a high resolution PET with nsec time resolution,” IEEE Trans. Nucl. Sci., vol. NS–42 (submitted for publication), 1995.
-
(1995)
IEEE Trans. Nucl. Sci.
, vol.NS–42
-
-
Schmelz, C.1
Bradbury, S.M.2
Holl, I.3
|