Volumn 42, Issue 8, 1995, Pages 777-785

The Application of Cepstral Coefficients and Maximum Likelihood Method in EMG Pattern Recognition

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CLASSIFICATION (OF INFORMATION); FEATURE EXTRACTION; MATHEMATICAL MODELS; MEDICAL IMAGING; MUSCLE; REGRESSION ANALYSIS; SIGNAL PROCESSING;

EID: 0029347476     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.398638     Document Type: Article
Times cited : (98)

References (21)
  • 1
    • 0016482611 scopus 로고
    • Functional separation of EMG signals via ARMA identification methods for prosthesis control purposes
    • Mar.
    • D. Graupe and W. K. Cline, “Functional separation of EMG signals via ARMA identification methods for prosthesis control purposes,” IEEE Trans. Syst., Man, Cyber., vol. SMC-5, pp. 252–259, Mar. 1975.
    • (1975) IEEE Trans. Syst., Man, Cyber. , vol.SMC-5 , pp. 252-259
    • Graupe, D.1    Cline, W.K.2
  • 2
    • 0020332044 scopus 로고
    • EMG pattern analysis and classification for a prosthetic arm
    • June
    • G. N. Saridis and T. P. Gootee, “EMG pattern analysis and classification for a prosthetic arm,” IEEE Trans. Biomed. Eng., vol. BME-29, pp. 403–412, June 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.BME-29 , pp. 403-412
    • Saridis, G.N.1    Gootee, T.P.2
  • 3
    • 0027135489 scopus 로고
    • A new strategy for multifunction myoelectric control
    • Jan.
    • B. Hudgins, P. Parker, and R. N. Scott, “A new strategy for multifunction myoelectric control,” IEEE Trans. Biomed. Eng., vol. 40, pp. 82–94, Jan. 1993.
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , pp. 82-94
    • Hudgins, B.1    Parker, P.2    Scott, R.N.3
  • 4
    • 0020641942 scopus 로고
    • Upper extremity limb function discrimination using EMG signal analysis
    • Jan.
    • P. C. Doerschuk, K. E. Gustafson, and A. S. Willsky, “Upper extremity limb function discrimination using EMG signal analysis,” IEEE Trans. Biomed. Eng., vol. BME-30, pp. 18–28, Jan. 1983.
    • (1983) IEEE Trans. Biomed. Eng. , vol.BME-30 , pp. 18-28
    • Doerschuk, P.C.1    Gustafson, K.E.2    Willsky, A.S.3
  • 5
    • 0024000563 scopus 로고
    • The electromyogram (EMG) as a control signal for functional neuromuscular stimulation—Part I: Autoregressive modeling as a mean of EMG signature discrimination
    • Apr.
    • G. Hefftner, W. Zucchini, and G. G. Jaros, “The electromyogram (EMG) as a control signal for functional neuromuscular stimulation—Part I: Autoregressive modeling as a mean of EMG signature discrimination,” IEEE Trans. Biomed. Eng., vol. 35, pp. 228–237, Apr. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 228-237
    • Hefftner, G.1    Zucchini, W.2    Jaros, G.G.3
  • 6
    • 0024000396 scopus 로고
    • The electromyogram (EMG) as a control signal for functional neuromuscular stimulation—Part II: Practical demonstration of the EMG signature discrimination system
    • Apr.
    • G. Hefftner and G. G. Jaros, “The electromyogram (EMG) as a control signal for functional neuromuscular stimulation—Part II: Practical demonstration of the EMG signature discrimination system,” IEEE Trans. Biomed. Eng., vol. 35, pp. 238–242, Apr. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 238-242
    • Hefftner, G.1    Jaros, G.G.2
  • 7
    • 0024058986 scopus 로고
    • The identification of time series models of lower extremity EMG for the control of prostheses using Box-Jenkins criteria
    • Aug.
    • R. J. Triolo, D. H. Nash, and G. D. Moskowitz, “The identification of time series models of lower extremity EMG for the control of prostheses using Box-Jenkins criteria,” IEEE Trans. Biomed. Eng., vol. 35, pp. 584–594, Aug. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 584-594
    • Triolo, R.J.1    Nash, D.H.2    Moskowitz, G.D.3
  • 8
    • 0021971558 scopus 로고
    • Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses
    • D. Graupe, J. Salahi, and D. Zhang, “Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses,” J. Biomed. Eng., vol. 7, pp. 18–29, 1985.
    • (1985) J. Biomed. Eng. , vol.7 , pp. 18-29
    • Graupe, D.1    Salahi, J.2    Zhang, D.3
  • 9
    • 0024698079 scopus 로고
    • EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking
    • July
    • D. Graupe, “EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking,” IEEE Trans. Biomed. Eng., vol. 36, pp. 711–719, July 1989.
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 711-719
    • Graupe, D.1
  • 10
    • 0016067897 scopus 로고
    • Effectiveness of linear prediction characteristics of the speech wave for automatic speaker identification and verification
    • June
    • B. S. Atal, “Effectiveness of linear prediction characteristics of the speech wave for automatic speaker identification and verification,” J. Acoust. Soc. Amer., vol. 55, no. 6, pp. 1304–1312, June 1974.
    • (1974) J. Acoust. Soc. Amer. , vol.55 , Issue.6 , pp. 1304-1312
    • Atal, B.S.1
  • 12
    • 0016495091 scopus 로고
    • Linear prediction: A tutorial review
    • Apr.
    • J. Makhoul, “Linear prediction: A tutorial review,” Proc. IEEE, vol. 63, pp. 561–580, Apr. 1975.
    • (1975) Proc. IEEE , vol.63 , pp. 561-580
    • Makhoul, J.1
  • 13
    • 0000090514 scopus 로고
    • A weighted cepstral distance measure for speech recognition
    • Oct.
    • Y. Tohkura, “A weighted cepstral distance measure for speech recognition,” IEEE Trans. Acoust., Speech, Signal Processing, vol. ASSP-35, pp. 1414–1422, Oct. 1987.
    • (1987) IEEE Trans. Acoust., Speech, Signal Processing , vol.ASSP-35 , pp. 1414-1422
    • Tohkura, Y.1
  • 21


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.