Volumn 17, Issue 5, 1995, Pages 372-379

Three-dimensional finite element stress analysis of the polypropylene, ankle-foot orthosis: static analysis

Author keywords

ankle foot orthosis; polypropylene; static analysis; Stress analysis

Indexed keywords

COMPUTER AIDED DESIGN; COMPUTER SIMULATION; ELASTIC MODULI; FINITE ELEMENT METHOD; LIGAMENTS; STIFFNESS; STRESS ANALYSIS; THREE DIMENSIONAL; TISSUE;

EID: 0029329196     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/1350-4533(95)97317-I     Document Type: Article
Times cited : (85)

References (23)
  • 1
    • 0024119072 scopus 로고
    • The three dimensional kinematics and flexibility characteristics of the human ankle and subtalar joint—part II: flexibility characteristics
    • (1988) J Biomech Engr , vol.110 , pp. 374-385
    • Chen1    Siegler2    Schneck3
  • 6
    • 0022403775 scopus 로고
    • Clinical use and fabrication of molded thermoplastic foot orthotic devices: suggestion from the field
    • (1985) Physical Therapy , vol.65 , pp. 1679-1682
    • Doxey1
  • 7
    • 0023455493 scopus 로고
    • A structural model for molded thermoplastic ankle-foot orthoses
    • (1987) J Biomech Engr , vol.109 , pp. 305-310
    • Leone1
  • 11
    • 84916568388 scopus 로고
    • One more step in redesigning the ankle-foot orthosis
    • (1987) SOMA , vol.2 , pp. 36-39
    • Lam1    Downing2    Reddy3
  • 16
    • 0342284910 scopus 로고
    • Anthropometric studies of the human foot and ankle
    • Biomechanics Lab., Univ. of Cal. Tech, San Francisco
    • (1968) Technical Report
    • Isman1    Inman2
  • 22
    • 0027006448 scopus 로고
    • Stress distribution in a physical buttock model: effects of simulated bone geometry
    • (1992) J. Biomech. , vol.25 , pp. 1403-1411
    • Candadai1    Reddy2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.