Fast SPECT Simulation Including Object Shape Dependent Scatter

Author keywords

[No Author keywords available]

Indexed keywords

CYLINDRICAL PHANTOM; DIGITAL BRAIN PHANTOM; ENERGY WINDOWS; OBJECT CURVATURE; POINT SPREAD FUNCTION MODEL; PROJECTION DATA; SCATTER TO PRIMARY RATIO; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TRIANGULAR PHANTOM;

EID: 0029324936     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.387709     Document Type: Article
Times cited : (40)

References (55)
  • 1
    • 0019526041 scopus 로고
    • Analysis of SPECT including scatter and attenuation using sophisticated Monte Carlo modeling methods
    • J. Beck. R. Jaszczak, R. Coleman. C. Sterner, and P. Nolte, “Analysis of SPECT including scatter and attenuation using sophisticated Monte Carlo modeling methods,” IEEE Trans. Nucl. Sci., vol. NS-29, pp. 506–511, 1982.
    • (1982) IEEE Trans. Nucl. Sci. , vol.NS-29 , pp. 506-511
    • Beck, J.1    Jaszczak, R.2    Coleman, R.3    Sterner, C.4    Nolte, P.5
  • 2
    • 0002561583 scopus 로고
    • Computer simulated cardiac SPECT data for use in evaluating reconstruction algorithms
    • NATO ASI Series F98, A. E. Todd-Pokropek and M. A. Viergever. Eds. Berlin: Springer-Verlag
    • D. Gilland, B. Tsui, H. Hu, and J. Perry, “Computer simulated cardiac SPECT data for use in evaluating reconstruction algorithms,” in Medical Images: Formation, Handling and Evaluation, NATO ASI Series F98, A. E. Todd-Pokropek and M. A. Viergever. Eds. Berlin: Springer-Verlag, 1992, pp. 523–536.
    • (1992) Medical Images: Formation, Handling and Evaluation , pp. 523-536
    • Gilland, D.1    Tsui, B.2    Hu, H.3    Perry, J.4
  • 3
    • 0024713937 scopus 로고
    • A Monte Carlo program for the simulation of scintillation camera characteristics
    • M. Ljungberg and S. Strand, “A Monte Carlo program for the simulation of scintillation camera characteristics,” Comp. Meth. Prog. Biomed., vol. 29, pp. 257–272. 1989.
    • (1989) Comp. Meth. Prog. Biomed. , vol.29 , pp. 257-272
    • Ljungberg, M.1    Strand, S.2
  • 4
    • 84968304063 scopus 로고
    • Voxel based calculation of nuclear medicine images and applied variance reduction techniques
    • A. C. F. Colchester and D. J. Hawkes, Eds., Lecture Notes in Computer Science 511. Berlin: Springer-Verlag
    • G. Zubal and C. Harrel, “Voxel based calculation of nuclear medicine images and applied variance reduction techniques,” in Information Processing in Medical Imaging, A. C. F. Colchester and D. J. Hawkes, Eds., Lecture Notes in Computer Science 511. Berlin: Springer-Verlag, 1991. pp. 23-33.
    • (1991) Information Processing in Medical Imaging , pp. 23-33
    • Zubal, G.1    Harrel, C.2
  • 6
    • 0026923449 scopus 로고
    • Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems
    • H. Wang, R. Jaszczak, and R. Coleman, “Solid geometry-based object model for Monte Carlo simulated emission and transmission tomographic imaging systems,” IEEE Trans. Med. Imag., vol. 11, pp. 361–372. 1992.
    • (1992) IEEE Trans. Med. Imag. , vol.11 , pp. 361-372
    • Wang, H.1    Jaszczak, R.2    Coleman, R.3
  • 7
    • 0023029877 scopus 로고
    • Inverse Monte Carlo as a unified reconstruction algorithm for ECT
    • C. Floyd, R. Jaszczak, K. Greer, and R. Coleman, “Inverse Monte Carlo as a unified reconstruction algorithm for ECT,” J. Nucl. Med., vol. 27, pp. 1577–1585, 1986.
    • (1986) J. Nucl. Med. , vol.27 , pp. 1577-1585
    • Floyd, C.1    Jaszczak, R.2    Greer, K.3    Coleman, R.4
  • 8
    • 0001579739 scopus 로고
    • Implementation of simultaneous attenuation and detector response correction in SPECT
    • B. Tsui, H. Hu. D. Gilland, and G. Gullberg, “Implementation of simultaneous attenuation and detector response correction in SPECT,” IEEE Trans. Nucl. Sci., vol. NS-35, pp. 778–783, 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.NS-35 , pp. 778-783
    • Tsui, B.1    Hu, H.2    Gilland, D.3    Gullberg, G.4
  • 10
    • 0024569815 scopus 로고
    • Compensation of spatial resolution in SPECT with conjugate gradient reconstruction technique
    • A. Formiconi, A. Pupi, and A. Passeri, “Compensation of spatial resolution in SPECT with conjugate gradient reconstruction technique,” Phys. Med. Biol., vol. 34, pp. 68–84, 1989.
    • (1989) Phys. Med. Biol. , vol.34 , pp. 68-84
    • Formiconi, A.1    Pupi, A.2    Passeri, A.3
  • 11
    • 0026139673 scopus 로고
    • Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction
    • G. Zeng, G. Gulberg, B. Tsui, and J. Terry. “Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction,” IEEE Trans. Nucl. Sci., vol. 38, pp. 693–703, 1991.
    • (1991) IEEE Trans. Nucl. Sci. , vol.38 , pp. 693-703
    • Zeng, G.1    Gulberg, G.2    Tsui, B.3    Terry, J.4
  • 13
    • 0026582126 scopus 로고
    • Three-dimensional photon detection kernels and their application to SPECT reconstruction
    • M. Smith, C. Floyd, R. Jaszczak, and R. Coleman, “Three-dimensional photon detection kernels and their application to SPECT reconstruction,” Phys. Med. Biol., vol. 37, pp. 605–621, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 605-621
    • Smith, M.1    Floyd, C.2    Jaszczak, R.3    Coleman, R.4
  • 14
    • 0026532033 scopus 로고
    • Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions
    • Z. Liang, T. Turkington, D. Gilland, R. Jaszczak, and R. Coleman. “Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions,” Phys. Med. Biol., vol. 37, pp. 587–603, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 587-603
    • Liang, Z.1    Turkington, T.2    Gilland, D.3    Jaszczak, R.4    Coleman, R.5
  • 15
    • 0026837502 scopus 로고
    • The GEM MAP algorithm with 3-D SPECT system response
    • T. Hebert and S. Gopal, “The GEM MAP algorithm with 3-D SPECT system response,” IEEE Trans. Med. Imag., vol. 11, pp. 81–90, 1992.
    • (1992) IEEE Trans. Med. Imag. , vol.11 , pp. 81-90
    • Hebert, T.1    Gopal, S.2
  • 16
    • 0027664070 scopus 로고
    • 3-D maximum a priori estimation for single photon emission computed tomography on massively parallel computers
    • M. Miller and C. Butler, “3-D maximum a priori estimation for single photon emission computed tomography on massively parallel computers,” IEEE Trans. Med. Imag., vol. 12, pp. 560–565, 1993.
    • (1993) IEEE Trans. Med. Imag. , vol.12 , pp. 560-565
    • Miller, M.1    Butler, C.2
  • 17
    • 0027644795 scopus 로고
    • A practical method for incorporating scatter in a projector-backprojector for accurate scatter compensation in SPECT
    • E. Frey and B. Tsui, “A practical method for incorporating scatter in a projector-backprojector for accurate scatter compensation in SPECT,” IEEE Trans. Nucl. Sci., vol. 40, pp. 1107–1116, 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1107-1116
    • Frey, E.1    Tsui, B.2
  • 18
    • 0027649213 scopus 로고
    • A fast projector backprojector pair modeling the asymmetric, spatially varying scatter response in SPECT imaging
    • E. Frey, Z. Lu, and B. Tsui, “A fast projector backprojector pair modeling the asymmetric, spatially varying scatter response in SPECT imaging,” IEEE Trans. Nucl. Sci., vol. 40, pp. 1192–1197, 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1192-1197
    • Frey, E.1    Lu, Z.2    Tsui, B.3
  • 19
    • 0028123987 scopus 로고
    • Quantitative SPECT: Basics and clinical considerations
    • B. Tsui, X. Zhao, E. Frey, and W. McCartney, “Quantitative SPECT: Basics and clinical considerations,” Sem. Nucl. Med., vol. 24, pp. 38–65, 1994.
    • (1994) Sem. Nucl. Med. , vol.24 , pp. 38-65
    • Tsui, B.1    Zhao, X.2    Frey, E.3    McCartney, W.4
  • 20
    • 84936895949 scopus 로고
    • Fast SPECT simulation and accurate reconstruction based on an analytic object shape dependent scatter model
    • F. Beekman, C. Kamphuis, W. van Beek, A. Hoekstra, P. van Rijk, and M. Viergever, “Fast SPECT simulation and accurate reconstruction based on an analytic object shape dependent scatter model,” J. Nucl. Med., vol. 35, p. 28P, 1994.
    • (1994) J. Nucl. Med. , vol.35 , pp. 28P
    • Beekman, F.1    Kamphuis, C.2    van Beek, W.3    Hoekstra, A.4    van Rijk, P.5    Viergever, M.6
  • 22
    • 0025416078 scopus 로고
    • A projector-backprojector pair which accounts for the depth and distance dependent blurring in SPECT
    • B. Penney, M. King, and K. Knesaurek, “A projector-backprojector pair which accounts for the depth and distance dependent blurring in SPECT,” IEEE Trans. Nucl. Sci., vol. 37, pp. 681–686, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 681-686
    • Penney, B.1    King, M.2    Knesaurek, K.3
  • 23
    • 0026055761 scopus 로고
    • Three-dimensional SPECT simulations of a complex three-dimensional mathematical brain model and measurement of a three-dimensional physical brain phantom
    • H. Kim, B. Tsui, B. Zeeberg, F. Fahey, N. Alden, E. Hoffman, and R. Reba, “Three-dimensional SPECT simulations of a complex three-dimensional mathematical brain model and measurement of a three-dimensional physical brain phantom,” J. Nucl. Med., vol. 32, pp. 1923–1930, 1991.
    • (1991) J. Nucl. Med. , vol.32 , pp. 1923-1930
    • Kim, H.1    Tsui, B.2    Zeeberg, B.3    Fahey, F.4    Alden, N.5    Hoffman, E.6    Reba, R.7
  • 24
    • 0026653712 scopus 로고
    • Spatial resolution and count density requirements in brain SPECT imaging
    • M. Madsen, W. Chang, and R. Hichwa, “Spatial resolution and count density requirements in brain SPECT imaging,” Phys. Med. Biol., vol. 37, pp. 1625–1636, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1625-1636
    • Madsen, M.1    Chang, W.2    Hichwa, R.3
  • 25
    • 0026469847 scopus 로고
    • SPECT quantification: A simplified method of attenuation and scatter correction for cardiac imaging
    • J. Galt, S. Cullom, and E. Garcia, “SPECT quantification: A simplified method of attenuation and scatter correction for cardiac imaging,” J. Nucl. Med., vol. 33, pp. 2232–2239, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 2232-2239
    • Galt, J.1    Cullom, S.2    Garcia, E.3
  • 27
    • 0025773696 scopus 로고
    • Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: A Monte Carlo study
    • M. Ljungberg and S. Strand, “Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: A Monte Carlo study,” J. Nucl. Med., vol. 32, pp. 1278–1284, 1991.
    • (1991) J. Nucl. Med. , vol.32 , pp. 1278-1284
    • Ljungberg, M.1    Strand, S.2
  • 28
    • 0025418434 scopus 로고
    • Improving the efficiency of emission tomography simulations using variance reduction techniques
    • D. Haynor, “Improving the efficiency of emission tomography simulations using variance reduction techniques,” IEEE Trans. Nucl. Sci., vol. 37, pp. 749–753, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 749-753
    • Haynor, D.1
  • 29
    • 0025744078 scopus 로고
    • Treatment of Compton scattering in maximum likelihood, expectation maximization reconstructions of SPECT images
    • J. Bowsher and C. Floyd, “Treatment of Compton scattering in maximum likelihood, expectation maximization reconstructions of SPECT images,” J. Nucl. Med., vol. 32, pp. 1285–1291, 1991.
    • (1991) J. Nucl. Med. , vol.32 , pp. 1285-1291
    • Bowsher, J.1    Floyd, C.2
  • 30
    • 0023100560 scopus 로고
    • Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations
    • S. Manglos, C. Floyd, R. Jaszczak, K. Greer, C. Harris, and R. Coleman, “Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations,” Phys. Med. Biol., vol. 32, pp. 335–343, 1987.
    • (1987) Phys. Med. Biol. , vol.32 , pp. 335-343
    • Manglos, S.1    Floyd, C.2    Jaszczak, R.3    Greer, K.4    Harris, C.5    Coleman, R.6
  • 31
    • 0027642289 scopus 로고
    • Solid geometry based modeling of nonuniform attenuation and Compton scattering in objects for SPECT imaging systems
    • H. Wang, R. Jaszczak, D. Gilland, K. Greer, and R. E. Coleman, “Solid geometry based modeling of nonuniform attenuation and Compton scattering in objects for SPECT imaging systems,” IEEE Trans. Nucl. Sci., vol. 40, pp. 1305–1312, 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1305-1312
    • Wang, H.1    Jaszczak, R.2    Gilland, D.3    Greer, K.4    Coleman, R.E.5
  • 32
    • 0028493568 scopus 로고
    • A new phantom for fast determination of the scatter response of a gamma camera
    • F. Beekman, E. Frey, C. Kamphuis, B. Tsui, and M. Viergever, “A new phantom for fast determination of the scatter response of a gamma camera,” IEEE Trans. Nucl. Sci., vol. 41, pp. 1481–1488, 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 1481-1488
    • Beekman, F.1    Frey, E.2    Kamphuis, C.3    Tsui, B.4    Viergever, M.5
  • 33
    • 0011956707 scopus 로고
    • Results of scattering in radioisotope imaging
    • M. Dresser and G. Knoll, “Results of scattering in radioisotope imaging,” IEEE Trans. Nucl. Sci., vol. NS-20, pp. 266–272, 1973.
    • (1973) IEEE Trans. Nucl. Sci. , vol.NS-20 , pp. 266-272
    • Dresser, M.1    Knoll, G.2
  • 34
    • 0021166670 scopus 로고
    • Improved SPECT quantification using compensation for scattered photons
    • R. Jaszczak, K. Greer, and C. Floyd, “Improved SPECT quantification using compensation for scattered photons,” J. Nucl. Med., vol. 25, pp. 893–900, 1984.
    • (1984) J. Nucl. Med. , vol.25 , pp. 893-900
    • Jaszczak, R.1    Greer, K.2    Floyd, C.3
  • 35
    • 0026528724 scopus 로고
    • A dual photopeak window method for scatter correction
    • M. King, G. Hademenos, and S. Glick, “A dual photopeak window method for scatter correction,” J. Nucl. Med., vol. 33, pp. 605–612, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 605-612
    • King, M.1    Hademenos, G.2    Glick, S.3
  • 36
    • 0027574203 scopus 로고
    • A Monte Carlo investigation of the dual photopeak window scatter correction method
    • G. Hademenos, M. Ljungberg, M. King, and S. Glick, “A Monte Carlo investigation of the dual photopeak window scatter correction method,” IEEE Trans. Nucl. Sci., vol. 40, pp. 179–185, 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 179-185
    • Hademenos, G.1    Ljungberg, M.2    King, M.3    Glick, S.4
  • 38
    • 0025416077 scopus 로고
    • 3-D phantom to simulate cerebral bloodflow and metabolic images for PET
    • E. Hoffman, P. Cutler, W. Digby, and J. Maziotta, “3-D phantom to simulate cerebral bloodflow and metabolic images for PET,” IEEE Trans. Nucl. Sci., vol. 37, pp. 616–620, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 616-620
    • Hoffman, E.1    Cutler, P.2    Digby, W.3    Maziotta, J.4
  • 41
    • 0022367658 scopus 로고
    • Deconvolution of Compton scatter in SPECT
    • C. Floyd, R. Jaszczak, K. Greer, and R. Coleman, “Deconvolution of Compton scatter in SPECT,” J. Nucl. Med., vol. 26, pp. 403–408, 1985.
    • (1985) J. Nucl. Med. , vol.26 , pp. 403-408
    • Floyd, C.1    Jaszczak, R.2    Greer, K.3    Coleman, R.4
  • 42
    • 84936893159 scopus 로고
    • A fast projector backprojector pair modeling the nonstationary scatter response in SPECT imaging
    • F. Kirsten, Ed. Piscataway, NJ: IEEE Press
    • E. Frey, Z. Ju, and B. Tsui, “A fast projector backprojector pair modeling the nonstationary scatter response in SPECT imaging,” in Conference Record of 1992 IEEE Nuclear Science Symposium and Medical Imaging Conference, F. Kirsten, Ed. Piscataway, NJ: IEEE Press, 1993, vol. 2, pp. 1032–1034.
    • (1993) Conference Record of 1992 IEEE Nuclear Science Symposium and Medical Imaging Conference , vol.2 , pp. 1032-1034
    • Frey, E.1    Ju, Z.2    Tsui, B.3
  • 44
    • 84923326015 scopus 로고
    • A practical projector-backprojector modeling attenuation, detector response and scatter for accurate scatter response compensation in SPECT
    • Piscataway, NJ: IEEE Press
    • E. Frey and B. Tsui, “A practical projector-backprojector modeling attenuation, detector response and scatter for accurate scatter response compensation in SPECT,” in Conference Record of 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference. Piscataway, NJ: IEEE Press, 1992, pp. 1777–1781.
    • (1992) Conference Record of 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference , pp. 1777-1781
    • Frey, E.1    Tsui, B.2
  • 45
    • 0028493578 scopus 로고
    • Modeling the scatter response function in inhomogeneous scattering media for SPECT
    • E. Frey and B. Tsui, “Modeling the scatter response function in inhomogeneous scattering media for SPECT,” IEEE Trans. Nucl. Sci., vol. 41, pp. 1585–1593, 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 1585-1593
    • Frey, E.1    Tsui, B.2
  • 47
    • 0019136137 scopus 로고
    • The geometric transfer function component for scintillation camera collimators with straight parallel holes
    • C. Metz, F. Atkins, and R. Beck, “The geometric transfer function component for scintillation camera collimators with straight parallel holes,” Phys. Med. Biol., vol. 25, pp. 1059–1070, 1980.
    • (1980) Phys. Med. Biol. , vol.25 , pp. 1059-1070
    • Metz, C.1    Atkins, F.2    Beck, R.3
  • 51
    • 0343401303 scopus 로고
    • A comparison of scatter compensation methods in SPECT: Subtraction-based techniques versus iterative reconstruction with accurate modeling of the scatter response
    • F. Kirsten, Ed. Piscataway, NJ: IEEE Press
    • E. Frey, B. Tsui, and M. Ljungberg, “A comparison of scatter compensation methods in SPECT: Subtraction-based techniques versus iterative reconstruction with accurate modeling of the scatter response,” in Conference Record of 1992 IEEE Nuclear Science Symposium and Medical Imaging Conference, F. Kirsten, Ed. Piscataway, NJ: IEEE Press, 1993, pp. 1035–1037.
    • (1993) Conference Record of 1992 IEEE Nuclear Science Symposium and Medical Imaging Conference , pp. 1035-1037
    • Frey, E.1    Tsui, B.2    Ljungberg, M.3
  • 52
    • 0026221904 scopus 로고
    • A practical method for position-dependent Compton-scatter correction in single photon emission CT
    • K. Ogawa, Y. Harata, and T. Ichihara, “A practical method for position-dependent Compton-scatter correction in single photon emission CT,” IEEE Trans. Med. Imag., vol. 10, pp. 408–412, 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , pp. 408-412
    • Ogawa, K.1    Harata, Y.2    Ichihara, T.3
  • 53
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. Shepp and Y. Vardi, “Maximum likelihood reconstruction for emission tomography,” IEEE Trans. Med. Imag., vol. MI-1, pp. 113–122, 1982.
    • (1982) IEEE Trans. Med. Imag. , vol.MI-1 , pp. 113-122
    • Shepp, L.1    Vardi, Y.2
  • 54
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, “EM reconstruction algorithms for emission and transmission tomography,” J. Comput. Assist. Tomog., vol. 8, pp. 306–316, 1985.
    • (1985) J. Comput. Assist. Tomog. , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.