메뉴 건너뛰기




Volumn 31, Issue 2, 1995, Pages 1266-1275

Sensitive and Quick Response Micro Magnetic Sensor Utilizing Magneto-Impedance in Co-rich Amorphous Wires

Author keywords

[No Author keywords available]

Indexed keywords

AMORPHOUS MATERIALS; CIRCUIT OSCILLATIONS; COBALT ALLOYS; ELECTRIC CONDUCTIVITY OF SOLIDS; ELECTRIC IMPEDANCE; FEEDBACK; MAGNETIC DEVICES; MAGNETOELECTRIC EFFECTS; SENSITIVITY ANALYSIS; WIRE;

EID: 0029276296     PISSN: 00189464     EISSN: 19410069     Source Type: Journal    
DOI: 10.1109/20.364817     Document Type: Article
Times cited : (122)

References (21)
  • 1
    • 0015316542 scopus 로고
    • Recent Advances in Fluxgate Magnetometry
    • vol. - March
    • D.I. Gordon, R.E. Brown, “Recent Advances in Fluxgate Magnetometry,” IEEE Trans. Magn., vol.8, pp. 76–82, March 1972.
    • (1972) IEEE Trans. Magn. , vol.8 , pp. 76-82
    • Gordon, D.I.1    Brown, R.E.2
  • 2
    • 0018455856 scopus 로고
    • The fluxgate magnetometer
    • F. Primdahl, “The fluxgate magnetometer,” J.Phys. E: Sci. Instrum., vol. 12, pp. 241–253, 1979.
    • (1979) J.Phys. E: Sci. Instrum. , vol.12 , pp. 241-253
    • Primdahl, F.1
  • 9
    • 0013101457 scopus 로고
    • Mechanism of the Magneto-Impedance Effect in Negative Magnetostrictive Amorphous Wires
    • L.V. Panina, K. Mohri, “Mechanism of the Magneto-Impedance Effect in Negative Magnetostrictive Amorphous Wires,” J. Mag. Soc. of Japan, vol.18, pp.245–249, 1994.
    • (1994) J. Mag. Soc. of Japan , vol.18 , pp. 245-249
    • Panina, L.V.1    Mohri, K.2
  • 12
    • 84937078958 scopus 로고
    • Giant magneto-impedance and magneto-inductive effects in amorphous alloys
    • vol. in press.
    • L.V. Panina, K. Mohri, K. Bushida, M. Noda, “Giant magneto-impedance and magneto-inductive effects in amorphous alloys,” IEEE Trans. Magn., vol.30, 1994 in press.
    • (1994) IEEE Trans. Magn. , vol.30
    • Panina, L.V.1    Mohri, K.2    Bushida, K.3    Noda, M.4
  • 14
    • 84937078960 scopus 로고
    • 6th MMM-Intermag Conf., Satellite Workshop on Rapidly Quenched Magnetic Wire & Applications, June 25, (Albuquerque).
    • K. Mohri, “Micro Magnetic Sensor Devices Using Amorphous Wires,” 6th MMM-Intermag Conf., Satellite Workshop on Rapidly Quenched Magnetic Wire & Applications, June 25, 1994 (Albuquerque).
    • (1994) Micro Magnetic Sensor Devices Using Amorphous Wires
    • Mohri, K.1
  • 16
    • 0027699181 scopus 로고
    • Quick Response Field Sensor Using 200 MHz Amorphous MI Element FET Multivibrator Resonance Oscillator
    • Y. Yoshida, T. Uchiyama, K. Mohri, S. Ohga, “Quick Response Field Sensor Using 200 MHz Amorphous MI Element FET Multivibrator Resonance Oscillator,” IEEE Trans.Magn., pp.3177–3179, 1993.
    • (1993) IEEE Trans.Magn. , pp. 3177-3179
    • Yoshida, Y.1    Uchiyama, T.2    Mohri, K.3    Ohga, S.4
  • 17
    • 84937077203 scopus 로고
    • Construction of Magnet Displacement Sensor Using Amorphous MI Element Resonant Multivibrator and Bio-mechanical Sensing.
    • M. Kato, T. Sone, K. Mohri, “Construction of Magnet Displacement Sensor Using Amorphous MI Element Resonant Multivibrator and Bio-mechanical Sensing.” Technical Meeting on Magnetics in IEE of Japan, MAG-94-80, pp. 47–56, 1994.
    • (1994) Technical Meeting on Magnetics in IEE of Japan , vol.MAG-94-80 , pp. 47-56
    • Kato, M.1    Sone, T.2    Mohri, K.3
  • 19
    • 0027702264 scopus 로고
    • Magneto-Inductive Effect in Tension-Annealed Amorphous Wires and MI Sensors
    • vol. - Nov.
    • K. Kawashima, T. Kohzawa, H. Yoshida, K. Mohri, “Magneto-Inductive Effect in Tension-Annealed Amorphous Wires and MI Sensors,” IEEE Trans. Magn., vol.29, pp. 3168–3170, Nov. 1993.
    • (1993) IEEE Trans. Magn. , vol.29 , pp. 3168-3170
    • Kawashima, K.1    Kohzawa, T.2    Yoshida, H.3    Mohri, K.4
  • 20
    • 0028547862 scopus 로고
    • Sensitive Magneto-Inductive Effect in Amorphous Wires Using High-Pass Filter and Micro Field Sensor
    • vol. Nov. in press.
    • K. Bushida, K. Mohri, “Sensitive Magneto-Inductive Effect in Amorphous Wires Using High-Pass Filter and Micro Field Sensor,” IEEE Trans. Magn., vol.30, Nov. 1994 in press.
    • (1994) IEEE Trans. Magn. , vol.30
    • Bushida, K.1    Mohri, K.2
  • 21
    • 0028549516 scopus 로고
    • Quick Response Large Current Sensor Using Amorphous MI Element Resonant Multivibrator
    • Nov. in press.
    • K. Inada, K. Mohri, K. Inuzuka, “Quick Response Large Current Sensor Using Amorphous MI Element Resonant Multivibrator,” IEEE Trans.Magn., vol. 30, Nov. 1994 in press.
    • (1994) IEEE Trans.Magn. , vol.30
    • Inada, K.1    Mohri, K.2    Inuzuka, K.3