Volumn 8, Issue 2, 1995, Pages 162-178

Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; CLUSTER ANALYSIS; DENTAL TECHNOLOGY; DENTURE; METHODOLOGY; NONPARAMETRIC TEST; QUALITY CONTROL; REPRODUCIBILITY; SCANNING ELECTRON MICROSCOPY; STANDARD; TOOTH BRUSHING; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 0029268937     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (120)

References (16)
  • 1
    • 0027018420 scopus 로고
    • Externally hexed implants, abutments, and transfer devices: A comprehensive overview
    • English CE. Externally hexed implants, abutments, and transfer devices: A comprehensive overview. Implant Dent 1992;1:273-282.
    • (1992) Implant Dent , vol.1 , pp. 273-282
    • English, C.E.1
  • 2
    • 0346329235 scopus 로고
    • The role of screws in implant systems
    • special suppl
    • Bealy K. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9(special suppl) 52-54.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 52-54
    • Bealy, K.1
  • 3
    • 0027564797 scopus 로고
    • Research status of prosthodontic procedures
    • Fenton AH, Zarb CA. Research status of prosthodontic procedures. Int J Prosthodont 1993;6:137-144.
    • (1993) Int J Prosthodont , vol.6 , pp. 137-144
    • Fenton, A.H.1    Zarb, C.A.2
  • 4
    • 0022666201 scopus 로고
    • Modified single and short span restorations supported by osseointegrated fixtures in the partially edentulous jaw
    • Jemt T. Modified single and short span restorations supported by osseointegrated fixtures in the partially edentulous jaw. J Prosthet Dent 1986;55:243-247.
    • (1986) J Prosthet Dent , vol.55 , pp. 243-247
    • Jemt, T.1
  • 6
    • 84995803327 scopus 로고
    • Clinical utilization of nonrelational capacity in osseointegrated prostheses: A technical note
    • Weinberg LA, Kruger B. Clinical utilization of nonrelational capacity in osseointegrated prostheses: A technical note. Int] Oral Maxillofac Implants 1994;9:326-332.
    • (1994) Int] Oral Maxillofac Implants , vol.9 , pp. 326-332
    • Weinberg, L.A.1    Kruger, B.2
  • 7
    • 84995772300 scopus 로고
    • Laney WR, Tolman TE (eds), I Proceedings of the 2nd International Congress on Tissue Integration in Oral, Orthopedic and MaxilloFacial Reconstruction 23-27 Sep 1990, Mayo Medical Center, Rochester, Minnesota.] Chicago, Quintessence
    • Binon PP, Weir DJ, Watanabe L, Walker L. Implant component compatibility. In: Laney WR, Tolman TE (eds). I Proceedings of the 2nd International Congress on Tissue Integration in Oral, Orthopedic and MaxilloFacial Reconstruction 23-27 Sep 1990, Mayo Medical Center, Rochester, Minnesota.] Chicago, Quintessence, 1992.
    • (1992) Implant component compatibility
    • Binon, P.P.1    Weir, D.J.2    Watanabe, L.3    Walker, L.4
  • 8
    • 0028389731 scopus 로고
    • External hex manufacturing tolerances of six implant systems: A pilot study
    • Schulte JK. External hex manufacturing tolerances of six implant systems: A pilot study. Implant Dent 1994;3:51-53.
    • (1994) Implant Dent , vol.3 , pp. 51-53
    • Schulte, J.K.1
  • 9
    • 0025926054 scopus 로고
    • The search for intimacy: Rotational accuracy of implant components for single-tooth, root-form implants
    • Barzilay I. The search for intimacy: Rotational accuracy of implant components for single-tooth, root-form implants. Dent Implantol Update 1991;2:5-7.
    • (1991) Dent Implantol Update , vol.2 , pp. 5-7
    • Barzilay, I.1
  • 10
    • 0039829366 scopus 로고
    • The role of screws in implant systems
    • spec suppl
    • Binon PP. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9(spec suppl):48-63.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 48-63
    • Binon, P.P.1
  • 11
    • 0024763839 scopus 로고
    • Complications with osseointegrated implants
    • Sones AD. Complications with osseointegrated implants. J Prosthet Deni 1989;62:581-585.
    • (1989) J Prosthet Deni , vol.62 , pp. 581-585
    • Sones, A.D.1
  • 12
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kaflus T, Bessing C. Loose gold screws frequently occur in full arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kaflus, T.1    Bessing, C.2
  • 14
    • 0027357731 scopus 로고
    • The biomechanics of force distribution in implant-supported prostheses
    • Weinberg LA. The biomechanics of force distribution in implant-supported prostheses. Int J Oral Maxillofac Implants 1993;1:19-31.
    • (1993) Int J Oral Maxillofac Implants , vol.1 , pp. 19-31
    • Weinberg, L.A.1
  • 15
    • 0028451094 scopus 로고
    • Tightening characteristics for screw joints in osseointegrated dental implants
    • Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screw joints in osseointegrated dental implants, J Prosthet Dent 1994;71:592-599.
    • (1994) J Prosthet Dent , vol.71 , pp. 592-599
    • Burguete, R.L.1    Johns, R.B.2    King, T.3    Patterson, E.A.4
  • 16
    • 0039829366 scopus 로고
    • The role of screws in implant systems
    • special suppl
    • Sutter F. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9(special suppl):51-52.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 51-52
    • Sutter, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.