메뉴 건너뛰기




Volumn 4, Issue 2, 1995, Pages 147-161

A Multidimensional Nonlinear Edge-Preserving Filter for Magnetic Resonance Image Restoration

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; APPROXIMATION THEORY; COMPUTER SIMULATION; EIGENVALUES AND EIGENFUNCTIONS; ELECTRIC FILTERS; IMAGE RECONSTRUCTION; LEAST SQUARES APPROXIMATIONS; MATHEMATICAL MODELS; PARALLEL PROCESSING SYSTEMS; SIGNAL FILTERING AND PREDICTION; VECTORS; WHITE NOISE;

EID: 0029253397     PISSN: 10577149     EISSN: 19410042     Source Type: Journal    
DOI: 10.1109/83.342189     Document Type: Article
Times cited : (59)

References (31)
  • 1
    • 0023873277 scopus 로고
    • MR subtraction angiography with matched filter
    • J. B. de Castro etal., “MR subtraction angiography with matched filter,” J. Comput. Assist. Tomogr., vol. 12, no. 2, pp. 355-362, 1988.
    • (1988) J. Comput. Assist. Tomogr. , vol.12 , Issue.2 , pp. 355-362
    • de Castro, J.B.1
  • 4
    • 0026923824 scopus 로고
    • A comparative analysis of several transformations for enhancement and segmentation of magnetic resonance image scene sequences
    • H. Soltanian-Zadeh, J. P. Windham, D. J. Peck, and A. E. Yagle, “A comparative analysis of several transformations for enhancement and segmentation of magnetic resonance image scene sequences,” IEEE Trans. Med. Imaging, vol. 11, no. 3, pp. 302-318, 1992.
    • (1992) IEEE Trans. Med. Imaging , vol.11 , Issue.3 , pp. 302-318
    • Soltanian-Zadeh, H.1    Windham, J.P.2    Peck, D.J.3    Yagle, A.E.4
  • 5
    • 0021863486 scopus 로고
    • Noise and filtration in magnetic resonance imaging
    • E. R. McVeigh, R. M. Henkelman, and M. J. Bronskill, “Noise and filtration in magnetic resonance imaging,” Med. Phys., vol. 12, no. 5, pp. 586-591, 1985.
    • (1985) Med. Phys. , vol.12 , Issue.5 , pp. 586-591
    • McVeigh, E.R.1    Henkelman, R.M.2    Bronskill, M.J.3
  • 6
    • 84913170436 scopus 로고
    • Signal-to-noise and contrast in MR imaging
    • F. W. Wehrli, “Signal-to-noise and contrast in MR imaging,” in NMR in Medicine, the Instrumentation and Clinical Applications (S. R. Thomas and R. L. Dixon, Eds.). Amer. Assoc. Phys. Medicine, Medical Physics, 1986, pp. 216-228, Monograph No. 14.
    • (1986) NMR in Medicine , Issue.14 , pp. 216-228
    • Wehrli, F.W.1
  • 8
    • 0025465145 scopus 로고
    • And edge detection using anisotropic diffusion
    • P. Perona and J. Malik, and edge detection using anisotropic diffusion,” IEEE Trans. Patt. Anal. Macine Intell., vol. 12, no. 7, pp. 629-639, 1990.
    • (1990) IEEE Trans. Patt. Anal. Macine Intell. , vol.12 , Issue.7 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 10
    • 0020904420 scopus 로고
    • A generalization of median filtering using linear combination of order statistics
    • A. C. Bovik, T. S. Huang, and D. C. Munson, “A generalization of median filtering using linear combination of order statistics,” IEEE Trans. Acoust, Speech, Signal Processing, vol. ASSP-31, no. 12, pp. 1342-1350, 1983.
    • (1983) IEEE Trans. Acoust , vol.ASSP-31 , Issue.12 , pp. 1342-1350
    • Bovik, A.C.1    Huang, T.S.2    Munson, D.C.3
  • 11
    • 0021373279 scopus 로고
    • Means and to median filters
    • means and to median filters,” IEEE Trans. Acoust, Speech, Signal Processing, vol. ASSP-32, no. 2, pp. 145-153, 1984.
    • (1984) IEEE Trans. Acoust, Speech, Signal Processing , vol.ASSP-32 , Issue.2 , pp. 145-153
  • 12
    • 0022083510 scopus 로고
    • Generalized median filtering and related nonlinear filtering techniques
    • Y. H. Lee and S. A.Kassam, “Generalized median filtering and related nonlinear filtering techniques,” IEEE Trans. Acoust, Speech, Signal Processing, vol. ASSP-33, no. 3, pp. 672-683, 1985.
    • (1985) IEEE Trans. Acoust , vol.ASSP-33 , Issue.3 , pp. 672-683
    • Lee, Y.H.1    Kassam, S.A.2
  • 13
    • 0023400547 scopus 로고
    • Generalized homomorphic and adaptive order statistic filters for the removal of impulsive and signal-dependent noise
    • R. Ding and A. N. Venetsanopoulos, “Generalized homomorphic and adaptive order statistic filters for the removal of impulsive and signal-dependent noise,” IEEE Trans. Circ. Syst., vol. CAS-34, no. 8, pp. 948-955, 1987.
    • (1987) IEEE Trans. Circ. Syst. , vol.CAS-34 , Issue.8 , pp. 948-955
    • Ding, R.1    Venetsanopoulos, A.N.2
  • 14
    • 0023453654 scopus 로고
    • Performance improvement of DPLL's in non-gaussian noise using robust estimators
    • W. B. McCain and C. D. McGillem, “Performance improvement of DPLL's in non-gaussian noise using robust estimators,” IEEE Trans. Acoust, Speech, Signal Processing, vol. ASSP-35, no. 11, pp. 1207-1216, 1987.
    • (1987) IEEE Trans. Acoust , vol.ASSP-35 , Issue.11 , pp. 1207-1216
    • McCain, W.B.1    McGillem, C.D.2
  • 15
    • 0024055394 scopus 로고
    • Adaptive trimmed mean filters for image restoration
    • A. Restrepo and A. C. Bovik, “Adaptive trimmed mean filters for image restoration,” IEEE Trans. Acoust, Speech, Signal Processing, vol. 36, no. 8, pp. 1326-1337, 1988.
    • (1988) IEEE Trans. Acoust , vol.36 , Issue.8 , pp. 1326-1337
    • Restrepo, A.1    Bovik, A.C.2
  • 18
    • 0006876021 scopus 로고
    • Preprocessing of MR image sequences using a new edge-preserving multi-dimensional filter
    • Aug.
    • H. Soltanian-Zadeh, J. P. Windham, and D. O. Hearshen, “Preprocessing of MR image sequences using a new edge-preserving multi-dimensional filter,” Presented at the 10th Ann. Mtg. Soc. Mag. Res. Med. (SMRM), San Francisco, CA, Aug. 10-16, 1991 (Abstract published in the SMRM Book of Abstracts, vol. 2, p. 748, 1991).
    • (1991) Presented at the 10th Ann. Mtg. Soc. Mag. Res. Med. (SMRM) , vol.2 , pp. 748
    • Soltanian-Zadeh, H.1    Windham, J.P.2    Hearshen, D.O.3
  • 21
    • 0023177446 scopus 로고
    • The contrast-to-noise in relaxation time, synthetic, and weighted-sum MR images
    • J. N. Lee and S. J. Riederer, “The contrast-to-noise in relaxation time, synthetic, and weighted-sum MR images,” Mag. Res. Med., vol. 5, pp. 13-22, 1987.
    • (1987) Mag. Res. Med. , vol.5 , pp. 13-22
    • Lee, J.N.1    Riederer, S.J.2
  • 22
    • 0025293545 scopus 로고
    • CNR enhancement in the presence interfering processes using linear filters
    • D. G. Brown et al., “CNR enhancement in the presence interfering processes using linear filters,” Mag. Res. Med., vol. 14, no. 1, pp. 79-96, 1990.
    • (1990) Mag. Res. Med. , vol.14 , Issue.1 , pp. 79-96
    • Brown, D.G.1
  • 23
    • 0025972048 scopus 로고
    • Target-point combination of MR Med
    • R. B. Buxton, “Target-point combination of MR Med., vol. 18, no. 1, pp. 102-115, 1991.
    • (1991) , vol.18 , Issue.1 , pp. 102-115
    • Buxton, R.B.1
  • 25
    • 0024394344 scopus 로고
    • Improved detectability in low SNR magnetic resonance images by means of phase corrected real reconstruction
    • M. A. Bernstein, D. M. Thomasson, and W. H. Penman, “Improved detectability in low SNR magnetic resonance images by means of phase corrected real reconstruction,” Med. Phys., vol. 16, no. 5, pp. 813-817, 1989.
    • (1989) Med. Phys. , vol.16 , Issue.5 , pp. 813-817
    • Bernstein, M.A.1    Thomasson, D.M.2    Penman, W.H.3
  • 26
    • 0027646834 scopus 로고
    • Optimal transformation for correcting partial volume averaging effects in magnetic resonance imaging
    • H. Soltanian-Zadeh, J. P. Windham, and A. E. Yagle: “Optimal transformation for correcting partial volume averaging effects in magnetic resonance imaging.” IEEE Trans. Nuc. Sci., vol. 40, no. 4, pp. 1204-1212, 1993.
    • (1993) IEEE Trans. Nuc. Sci. , vol.40 , Issue.4 , pp. 1204-1212
    • Soltanian-Zadeh, H.1    Windham, J.P.2    Yagle, A.E.3
  • 29
    • 0024280387 scopus 로고
    • Vector FIR-median hybrid filters for multispectral signals
    • P. Haavisto, P. Heinonen, and Y. Neuvo, “Vector FIR-median hybrid filters for multispectral signals,” Electron. Lett., vol. 24, no. 1, pp. 7-8, 1988.
    • (1988) Electron. Lett. , vol.24 , Issue.1 , pp. 7-8
    • Haavisto, P.1    Heinonen, P.2    Neuvo, Y.3
  • 30
    • 0026650636 scopus 로고
    • J. and accurate algorithm for volume determination in MRI
    • D. J. Peck, J. P. Windham, H. Soltanian-Zadeh, and J. and accurate algorithm for volume determination in MRI,” Med. Phys., vol. 19, no. 3, pp. 599-605, 1992.
    • (1992) Med. Phys. , vol.19 , Issue.3 , pp. 599-605
    • Peck, D.J.1    Windham, J.P.2    Soltanian-Zadeh, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.