메뉴 건너뛰기




Volumn 22, Issue 2, 1995, Pages 249-253

Intercomparison of normalized head-scatter factor measurement techniques

Author keywords

dosimetry; head scatter factor; measurement; radiation therapy

Indexed keywords

PHOTOELECTRONS; PHOTONS;

EID: 0028961527     PISSN: 00942405     EISSN: NA     Source Type: Journal    
DOI: 10.1118/1.597602     Document Type: Article
Times cited : (30)

References (9)
  • 1
    • 0018858258 scopus 로고
    • Revision of tissue-maximum ratio and scatter maximum ratio concepts for cobalt 60 and higher energy x-ray beams
    • F. M. Khan, W. Sewchand, J. Lee, and J. F. Williamson, “Revision of tissue-maximum ratio and scatter maximum ratio concepts for cobalt 60 and higher energy x-ray beams,” Med. Phys. 7, 230–237 (1980).
    • (1980) Med. Phys. , vol.7 , pp. 230-237
    • Khan, F.M.1    Sewchand, W.2    Lee, J.3    Williamson, J.F.4
  • 2
    • 0027465469 scopus 로고
    • Head-scatter factors in rectangular photon fields
    • M. Tatcher and B. E. Bjarngard, “Head-scatter factors in rectangular photon fields,” Med. Phys. 20, 205–206 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 205-206
    • Tatcher, M.1    Bjarngard, B.E.2
  • 3
    • 0025727879 scopus 로고
    • The determination of phantom and collimator scatter components of the output of megavoltage photon beams: Measurement of the collimator scatter part with a beam coaxial narrow cylindrical phantom
    • J. J. M. van Gasteren, S. Heukelom, H. J. van Kleffens, R. van Der Laarse. J. L. M. Venselaar, and C. F. Westermann, “The determination of phantom and collimator scatter components of the output of megavoltage photon beams: Measurement of the collimator scatter part with a beam coaxial narrow cylindrical phantom,” Radiother. Oncol. 20 250–257 (1991).
    • (1991) Radiother. Oncol. , vol.20 , pp. 250-257
    • Gasteren, J.J.M.1    Heukelom, S.2    Kleffens, H.J.3    Der Laarse, R.4    Venselaar, J.L.M.5    Westermann, C.F.6
  • 4
    • 0023234715 scopus 로고
    • Dosimetry of 24-MV x rays from a linear accelerator
    • G. Krithivas and S. N. Rao, “Dosimetry of 24-MV x rays from a linear accelerator,” Med. Phys. 14, 274–281 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 274-281
    • Krithivas, G.1    Rao, S.N.2
  • 5
    • 0022471631 scopus 로고
    • Head-scatter data for several linear accelerators (4–18 MV)
    • K. R. Kase and G. K. Svensson, “Head-scatter data for several linear accelerators (4–18 MV),” Med. Phys. 13, 530–532 (1986).
    • (1986) Med. Phys. , vol.13 , pp. 530-532
    • Kase, K.R.1    Svensson, G.K.2
  • 6
    • 0023905228 scopus 로고
    • Output factor constituents of a high energy photon beam
    • G. Luxton and M. A. Astrahan, “Output factor constituents of a high energy photon beam,” Med. Phys. 15, 88–91 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 88-91
    • Luxton, G.1    Astrahan, M.A.2
  • 7
    • 0026472120 scopus 로고
    • On the field size dependence of relative output form a linear accelerator
    • P. B. Dunscombe and J. M. Nieminen, “On the field size dependence of relative output form a linear accelerator,” Med. Phys. 19, 1441–1444 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 1441-1444
    • Dunscombe, P.B.1    Nieminen, J.M.2
  • 8
    • 84957241236 scopus 로고
    • The use of tissue-air ratio with high energy photon fields
    • Dissertation, University of Wisconsin-Madison, Madison, Wisconsin, May
    • B. R. Thomadsen, “The use of tissue-air ratio with high energy photon fields,” Dissertation, University of Wisconsin-Madison, Madison, Wisconsin, May, 1989.
    • (1989)
    • Thomadsen, B.R.1
  • 9
    • 84957232311 scopus 로고    scopus 로고
    • Characteristics of secondary electrons produced by 6-, 10-, and 24-MV photon beams
    • (submitted to Medical Physics)
    • P. A. Jursinic and T. R. Mackie, “Characteristics of secondary electrons produced by 6-, 10-, and 24-MV photon beams” (submitted to Medical Physics).
    • Jursinic, P.A.1    Mackie, T.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.