메뉴 건너뛰기




Volumn 10, Issue 1-2, 1995, Pages 181-193

Electron-transfer pathways in amperometric biosensors. Ferrocene-modified enzymes entrapped in conducting-polymer layers

Author keywords

amperometric biosensors; direct electron transfer; electron transfer mechanism; ferrocene derivatives; modified glucose oxidase; non leaking redox mediators; polypyrrole; redox relays

Indexed keywords

AMPEROMETRIC SENSORS; CHARGE TRANSFER; CONDUCTIVE FILMS; DERIVATIVES; ELECTRONS; ENZYME KINETICS; ENZYMES; GLUCOSE; MICROELECTRODES; POLYMERS; REDOX REACTIONS;

EID: 0028909544     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/0956-5663(95)96805-9     Document Type: Article
Times cited : (160)

References (41)
  • 9
    • 0039633245 scopus 로고
    • Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors
    • (1986) J. Chem. Soc. Faraday Trans. , vol.82 , pp. 1259-1264
    • Foulds1    Lowe2
  • 10
    • 0024110433 scopus 로고
    • Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
    • (1988) Anal. Chem. , vol.60 , pp. 2473-2478
    • Foulds1    Lowe2
  • 11
    • 0025366526 scopus 로고
    • Crosslinked redox gels containing glucose oxidase for amperometric biosensor applications
    • (1990) Anal. Chem. , vol.62 , pp. 258-263
    • Gregg1    Heller2
  • 16
    • 33750428427 scopus 로고
    • Electrical connection of enzyme redox centers to electrodes
    • (1992) J. Phys. Chem. , vol.96 , pp. 3579-3587
    • Heller1
  • 17
    • 0025053672 scopus 로고
    • Comparative evaluation of the blood glucose monitor ExacTech based upon precision profiles
    • (1990) Laboratoriumsmedizin , vol.14 , pp. 336-341
    • Holle1
  • 30
    • 0026140513 scopus 로고
    • Functionalized polypyrrole. A new material for the construction of biosensors
    • (1991) Synthetic Metals , vol.41 , pp. 429-432
    • Schuhmann1
  • 31
    • 0026152352 scopus 로고
    • Amperometric substrate determination in flow-injection systems with polypyrrole-enzyme electrodes
    • (1991) Sensors & Actuators B , vol.4 , pp. 41-49
    • Schuhmann1
  • 32
    • 0040134597 scopus 로고
    • Amperometric enzyme electrodes based on conducting polymers and modified enzymes
    • E. Pungor, 11–15 October 1992, Matrafüred, Ungarn, Akadémiai Kiadó, Budapest
    • (1993) Proceedings of BIOELECTROANALYSIS 2 , pp. 113-138
    • Schuhmann1
  • 41
    • 0000200816 scopus 로고
    • Covalent electropolymerization of glucose oxidase in polypyrrole. Evaluation of methods of pyrrole attachment to glucose oxidase on the performance of electropolymerized glucose sensors
    • (1993) Anal. Chem. , vol.65 , pp. 2067-2071
    • Yon Hin1    Smolander2    Crompton3    Lowe4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.