메뉴 건너뛰기




Volumn 197, Issue 2, 1995, Pages 421-425

Adrenal masses in patients with malignancy: Prospective comparison of echo-planar, fast spin-echo, and chemical shift MR imaging

Author keywords

Adrenal gland, MR; Adrenal gland, neoplasms

Indexed keywords

ADRENAL CANCER; ADRENAL CORTEX ADENOMA; ADRENAL METASTASIS; ADULT; AGED; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMALE; HUMAN; LUNG CANCER; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0028875331     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.197.2.7480686     Document Type: Article
Times cited : (66)

References (21)
  • 2
    • 0027476070 scopus 로고
    • Adrenal masses: Differentiation with chemical shift, fast low-angle shot MR imaging
    • Tsushima Y, Ishizaka H, Matsumoto M. Adrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging. Radiology 1993; 186:705-709.
    • (1993) Radiology , vol.186 , pp. 705-709
    • Tsushima, Y.1    Ishizaka, H.2    Matsumoto, M.3
  • 4
    • 0028986167 scopus 로고
    • MR imaging of adrenal masses: Value of chemical-shift imaging for distinguishing adenomas from other tumors
    • Bilbey JH, McLoughlin RF, Kurkjian PS, et al. MR imaging of adrenal masses: value of chemical-shift imaging for distinguishing adenomas from other tumors. AJR 1995; 164:637-642.
    • (1995) AJR , vol.164 , pp. 637-642
    • Bilbey, J.H.1    McLoughlin, R.F.2    Kurkjian, P.S.3
  • 5
    • 0028913931 scopus 로고
    • Echoplanar MR imaging for characterization of adrenal masses in patients with malignant neoplasms: Preliminary evaluation of calculated T2 relaxation values
    • Schwartz LH, Panicek DM, Koutcher JA, Heelan RT, Bains MS, Burt M. Echoplanar MR imaging for characterization of adrenal masses in patients with malignant neoplasms: preliminary evaluation of calculated T2 relaxation values. AJR 1995; 164:911-915.
    • (1995) AJR , vol.164 , pp. 911-915
    • Schwartz, L.H.1    Panicek, D.M.2    Koutcher, J.A.3    Heelan, R.T.4    Bains, M.S.5    Burt, M.6
  • 9
    • 0022641955 scopus 로고
    • Adrenal tissue characterization using MR imaging
    • Glazer GM, Woolsey EJ, Borrello J, et al. Adrenal tissue characterization using MR imaging. Radiology 1986; 158:73-79.
    • (1986) Radiology , vol.158 , pp. 73-79
    • Glazer, G.M.1    Woolsey, E.J.2    Borrello, J.3
  • 10
    • 0024381507 scopus 로고
    • MR characterization of adrenal masses: Field strength and pulse sequence considerations
    • Kier R, McCarthy S. MR characterization of adrenal masses: field strength and pulse sequence considerations. Radiology 1989; 171:671-674.
    • (1989) Radiology , vol.171 , pp. 671-674
    • Kier, R.1    McCarthy, S.2
  • 12
    • 0024362790 scopus 로고
    • Adrenal masses: Evaluation with fast gradient-echo MR imaging and Gd-DTPA-enhanced dynamic studies
    • Krestin GP, Steinbrich W, Friedmann G. Adrenal masses: evaluation with fast gradient-echo MR imaging and Gd-DTPA-enhanced dynamic studies. Radiology 1989; 171:675-680.
    • (1989) Radiology , vol.171 , pp. 675-680
    • Krestin, G.P.1    Steinbrich, W.2    Friedmann, G.3
  • 14
    • 0027567037 scopus 로고
    • Evaluation of adrenal masses with gadolinium enhancement and fat-suppressed MR imaging
    • Semelka RC, Shoenut JP, Lawrence PH, et al. Evaluation of adrenal masses with gadolinium enhancement and fat-suppressed MR imaging. J Magn Reson Imaging 1993; 3:337-343.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 337-343
    • Semelka, R.C.1    Shoenut, J.P.2    Lawrence, P.H.3
  • 15
    • 0025953560 scopus 로고
    • Differentiation between hemangiomas and metastases of the liver with ultrafast MR imaging: Preliminary results with T2 calculations
    • Goldberg MA, Saini S, Hahn PF, Egglin TK, Mueller PR. Differentiation between hemangiomas and metastases of the liver with ultrafast MR imaging: preliminary results with T2 calculations. AJR 1991; 157: 727-730.
    • (1991) AJR , vol.157 , pp. 727-730
    • Goldberg, M.A.1    Saini, S.2    Hahn, P.F.3    Egglin, T.K.4    Mueller, P.R.5
  • 16
    • 0022555963 scopus 로고
    • Errors in the measurements of T2 using multiple-echo MRI techniques. I. Effects of radiofrequency pulse imperfections
    • Majumdar S, Orphanoudakis SC, Gmitro A, O'Donnell M, Gore JC. Errors in the measurements of T2 using multiple-echo MRI techniques. I. Effects of radiofrequency pulse imperfections. Magn Reson Med 1986; 3:397-417.
    • (1986) Magn Reson Med , vol.3 , pp. 397-417
    • Majumdar, S.1    Orphanoudakis, S.C.2    Gmitro, A.3    O'Donnell, M.4    Gore, J.C.5
  • 17
    • 0022930453 scopus 로고
    • Errors in the measurements of T2 using multiple-echo MRI techniques. II. Effects of static field inhomogeneity
    • Majumdar S, Orphanoudakis SC, Gmitro A, O'Donnell M, Gore JC. Errors in the measurements of T2 using multiple-echo MRI techniques. II. Effects of static field inhomogeneity. Magn Reson Med 1986; 3:562-574.
    • (1986) Magn Reson Med , vol.3 , pp. 562-574
    • Majumdar, S.1    Orphanoudakis, S.C.2    Gmitro, A.3    O'Donnell, M.4    Gore, J.C.5
  • 18
    • 0024558264 scopus 로고
    • Accuracy and reproducibility of image derived relaxation parameters on a clinical 1.5 T magnetic resonance scanner
    • Masterson ME, McGary R, Schmitt K, Koutcher JA. Accuracy and reproducibility of image derived relaxation parameters on a clinical 1.5 T magnetic resonance scanner. Med Phys 1989; 16:225-233.
    • (1989) Med Phys , vol.16 , pp. 225-233
    • Masterson, M.E.1    McGary, R.2    Schmitt, K.3    Koutcher, J.A.4
  • 19
    • 0027157578 scopus 로고
    • Predictive value of image-guided adrenal biopsy: Analysis of results of 101 biopsies
    • Silverman SG, Mueller PR, Pinkney LP, Koenker RM, Seltzer SE. Predictive value of image-guided adrenal biopsy: analysis of results of 101 biopsies. Radiology 1993; 187:715-718.
    • (1993) Radiology , vol.187 , pp. 715-718
    • Silverman, S.G.1    Mueller, P.R.2    Pinkney, L.P.3    Koenker, R.M.4    Seltzer, S.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.