메뉴 건너뛰기




Volumn 18, Issue 11, 1995, Pages 2068-2087

Impedance to Defibrillation Countershock: Does an Optimal Impedance Exist?

Author keywords

countershock; defibrillation; impedance; implantable defibrillator

Indexed keywords

ARTICLE; CARDIOVERSION; COMPUTER MODEL; DEFIBRILLATION; ELECTRIC CURRENT; ELECTRODE; HUMAN; IMPEDANCE; TISSUE;

EID: 0028806652     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1995.tb03869.x     Document Type: Article
Times cited : (23)

References (141)
  • 2
    • 0022472742 scopus 로고
    • Activation during ventricular defibrillation in open‐chest dogs: Evidence of complete cessation and regeneration of ventricular fibrillation after unsuccessful shocks
    • (1986) J Clin Invest , vol.77 , pp. 810-823
    • Chen, P‐S1    Shibata, N2    Dixon, EG3
  • 4
    • 0025277643 scopus 로고
    • Comparison of activation during ventricular fibrillation and following unsuccessful defibrillation shocks in open chest dogs
    • (1990) Circ Res , vol.66 , pp. 1544-1560
    • Chen, P‐S1    Wolf, PD2    Melnick, SB3
  • 7
    • 0012281644 scopus 로고
    • Electrical treatment of cardiac arrest: A cardiac stimulator‐defibrillator
    • (1954) Surgery , vol.36 , Issue.8 , pp. 13-849
    • Hopps, JA1    Bigelow, WG.2
  • 12
    • 0017914483 scopus 로고
    • Local potential gradients as a unifying measure for thresholds of stimulation, standstill, tachyarrhythmia and fibrillation appearing after strong capacitor discharges
    • (1978) Adv Cardiol , vol.21 , pp. 268-278
    • Lepeschkin, E1    Jones, JL2    Rush, S3
  • 27
    • 0023002442 scopus 로고
    • The characterization of human transmyocardial impedance during implantation of the automatic internal cardioverter defibrillator
    • (1986) PACE , vol.9 , pp. 745-755
    • Lawrence, JH1    Brin, KP2    Halperin, HR3
  • 28
    • 0002165161 scopus 로고
    • Electrodes for transchest and ICD defibrillation and multifunctional electrodes
    • WA Tacker, Jr.,. St. Louis, MO, Mosby‐Book, Inc.
    • (1994) Defibrillation of the Heart , pp. 82-118
    • Geddes, LA.1
  • 29
    • 0025643175 scopus 로고
    • Inlrathoracic current flow during transthoracic defibrillation in dogs: Transcardiac current fraction
    • (1990) Circ Res , vol.67 , pp. 1405-1419
    • Deale, OC1    Lerman, BB.2
  • 31
    • 0025353199 scopus 로고
    • Changes in transmyocardial impedance during prolonged ventricular fibrillation: Implications for current flow and delivered energy during DC countershock
    • (1990) Am Heart J , vol.120 , pp. 334-339
    • Mahmud, R1    Hsia, P‐W2    Dolly, SR3
  • 32
    • 0019365075 scopus 로고
    • The discontinuous nature of propagation in normal canine cardiac muscle. Evidence for recurrent discontinuities of intracellular resistance that affect the membrane currents
    • (1981) Circ Res , vol.48 , pp. 39-54
    • Spach, MS1    Miller, WT2    Gbselowitz, DB3
  • 33
    • 0018365701 scopus 로고
    • Influence of cardiac fiber orientation on wavefront voltage, conduction velocity, and (tissue resistivity in the dog
    • (1979) CircRes , vol.44 , pp. 701-712
    • Roberts, DE1    Hersh, LT2    Scher, AM.3
  • 37
    • 0022691559 scopus 로고
    • Effect of microscopic and macroscopic discontinuities on the response of cardiac tissue to defibrillating (stimulating) currents
    • (1986) Med Biol Eng Comput , vol.24 , pp. 130-136
    • Plonsey, R1    Barr, RC.2
  • 38
  • 43
    • 0017877564 scopus 로고
    • Evaluation of the internal resistance, inductance and capacitance of intact damped sine wave defibrillators
    • (1978) Med Instrum , vol.1 , pp. 34-37
    • Babbs, CF1    Whistler, SJ.2
  • 46
    • 0015063242 scopus 로고
    • Engineering and physiological considerations of direct capacitor‐discharge ventricular defibrillation
    • (1971) Mod Biol Eng , vol.9 , pp. 185-199
    • Geddes, LA1    Tacker, WA.2
  • 48
    • 0018403525 scopus 로고
    • Temporary pacemaker treatment in open heart surgery: Variation in myocardial threshold, tissue and interface impedances in man
    • (1979) PACE , vol.2 , pp. 162-174
    • Ohm, OJ1    Morkrid, L2    Skagseth, E.3
  • 53
    • 0014088178 scopus 로고
    • The specific resistance of biological material: A compendium of data for the biomedical engineer and physiologist
    • (1967) Med Biol Eng , vol.5 , pp. 271-293
    • Geddes, LA1    Baker, LE.2
  • 54
    • 0017262178 scopus 로고
    • Directional differences of impulse spread in trabecular muscle from mammalian heart
    • (1976) J Physiol , vol.255 , pp. 335-346
    • Clerc, L.1
  • 55
    • 0027491142 scopus 로고
    • Optical recordings of the effect of electrical stimulation on action potential repolarization and the induction of reentry in two‐dimensional perfused rabbit epicardium
    • (Pt. 1)
    • (1993) Circulation , vol.88 , pp. 2402-2414
    • Knisley, SB1    Hill, BC.2
  • 59
    • 0026536358 scopus 로고
    • Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation
    • (1992) Circulation , vol.85 , pp. 1510-1523
    • Wharton, JM1    Wolf, PD2    Smith, WM3
  • 60
    • 0026566151 scopus 로고
    • Three‐dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes
    • (1992) Circulation , vol.85 , pp. 1857-1864
    • Tang, ASL1    Wolf, PD2    Afework, Y3
  • 64
    • 0026547706 scopus 로고
    • Synchronized repolarization after defibrillation shocks: A possible component of the defibrillation process demonstrated by optical recordings in rabbit heart
    • (1992) Circulation , vol.85 , pp. 1865-1878
    • Dillon, SM.1
  • 74
    • 0019497010 scopus 로고
    • Transthoracic resistance in human defibrillation: Influence of body weight, chest size serial shocks, paddle size and paddle contact pressure
    • (1981) Circulation , vol.63 , pp. 676-682
    • Kerber, WJ1    Grayzel, J.2    Hoyt, R3
  • 79
    • 0025352387 scopus 로고
    • Utility of low energy test shocks for estimation of cardiac and electrode impedance with implantable defibrillators
    • (1990) PACE , vol.13 , pp. 410-416
    • Leitch, JW1    Yee, R2    Klein, GJ3
  • 83
    • 0021170163 scopus 로고
    • Advance prediction of transthoracic impedance in human defibrillation and cardioversion: Importance of impedance in determining the success of low energy shocks
    • (1984) Circulation , vol.70 , pp. 303-308
    • Kerber, RE1    Kouba, C2    Martins, JB3
  • 93
    • 0023938827 scopus 로고
    • Energy, current, and success in defibrillation and cardioversion: Clinical studies using an automated impedance‐based method of energy adjustment
    • (1988) Circulation , vol.77 , pp. 1038-1046
    • Kerber, RE1    Martins, JB.2    Kienzle, MG3
  • 94
    • 85025276563 scopus 로고
    • Does determination of patch lead impedance by low energy shocks help to identify patients with an insufficient defibrillation threshold
    • (1990) PACE , vol.13 , pp. 1191
    • Block, M.1
  • 96
    • 0027412099 scopus 로고
    • The role of an engineering oriented medical research group in developing improved methods and devices for achieving ventricular defibrillation: The University of Missouri experience
    • (1993) PACE , vol.16 , pp. 95-124
    • Schuder, J.1
  • 103
    • 0016273357 scopus 로고
    • Myocardial necrosis from direct current countershock: Effect of paddle size and time interval between discharge
    • (1974) Circulation , vol.50 , pp. 956-961
    • Dahl, CF1    Ewy, GA2    Warner, ED3
  • 111
    • 0018751118 scopus 로고
    • Scaling current and energy with body weight: Requirements for the transthoracic ventricular defibrillation of calves as they grow from 50 to 150 kg
    • (1979) Circulation , vol.1 , pp. 187-194
    • Gold, JH1    Schuder, JC2    Stoeckle, H3
  • 113
    • 0017711854 scopus 로고
    • Effectiveness of direct current defibrillation: Role of paddle electrode size: II
    • (1977) Am Heart J , vol.93 , pp. 674-675
    • Ewy, GA1    Horan, WJ.2
  • 115
    • 0018014328 scopus 로고
    • Electrode system for permanent implantable defibrillators: Transvenous catheter and subcutaneous plate electrodes
    • (1978) Med Instrum , vol.12 , pp. 296-300
    • Ewy, GA1    Thomas, E2    Taren, D.3
  • 118
    • 0025910288 scopus 로고
    • Comparative efficacy of subcutaneous mesh and plate electrodes for nonthoracotomy canine defibrillation
    • (1991) PACE , vol.14 , pp. 1402-1410
    • Nogami, A1    Takahashi, A2    Nitta, J3
  • 123
    • 0025790406 scopus 로고
    • A new approach towards defibrillation electrodes: Highly conductive isotropic carbon fibers
    • (1991) PACE , vol.14 , pp. 1923-1928
    • Alt, E1    Theres, H2    Heinz, M3
  • 124
    • 85025292613 scopus 로고
    • Increased right ventricular coil length lowers defibrillation thresholds despite reduction in catheter diameter and total electrode surface
    • (1993) PACE , vol.16 , pp. 887
    • Leonelli, FM1    Kuo, CS2    Kroll, MW3
  • 132
    • 0025978836 scopus 로고
    • Defibrillation with low voltage using a left ventricular catheter and four cutaneous patch electrodes in dogs
    • (1991) PACE , vol.14 , pp. 443-451
    • Guse, PA1    Kavanagh, KM2    Alferness, CA3
  • 136
    • 0025788094 scopus 로고
    • Electroporation of cardiac cell membranes with monophasic or biphasic rectangular pulses
    • (1991) PACE , vol.14 , pp. 1887-1892
    • Tovar, O1    Tung, L.2
  • 141
    • 0028069948 scopus 로고
    • Troubleshooting implantable cardioverter defibrillater system malfunctions: The role of impedance measurements
    • (1994) PACE , vol.17 , pp. 1456-1461
    • Haddad, L1    Padula, LE2    Moreau, M3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.