메뉴 건너뛰기




Volumn 34, Issue 6, 1995, Pages 858-867

Locally focused mri

Author keywords

image acquisition; image reconstruction; MRI; spatial resolution

Indexed keywords

FOURIER TRANSFORMS; IMAGE ACQUISITION; IMAGE RECONSTRUCTION; IMAGE RESOLUTION; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING;

EID: 0028802389     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.1910340611     Document Type: Article
Times cited : (24)

References (37)
  • 6
    • 84981586282 scopus 로고
    • Locally focused MRI, in “Proc., SMR Workshop on Interventional MRI, Boston
    • (1994) , pp. 46
    • Cao, Y.1    Levin, D.N.2    Yao, L.3
  • 7
    • 84999293340 scopus 로고
    • Locally focused MRI, in “Proc., IEEE International Conference on Image Processing, IEEE Computer Society Press, Los Alamitos, CA
    • (1994) , pp. 30
    • Cao, Y.1    Levin, D.N.2
  • 12
    • 84981593556 scopus 로고
    • Reducing MR imaging time by one‐sided reconstruction, in “Topical Conf. Fast MRI Techniques,” Cleveland, Ohio
    • (1987)
    • Cappen, J.J.1    Van Est, A.2
  • 20
    • 84994942572 scopus 로고
    • Using an image database to constrain the acquisition and reconstruction of MR images of the human head, in “Proc., Soc. of Photo‐Optical Instrumentation Engineers, Medical Imaging, : Image Processing, Bellingham, WA, 1994,” p.
    • (1994) , pp. 258
    • Cao, Y.1    Levin, D.N.2
  • 22
    • 84981585914 scopus 로고
    • Using prior knowledge of human anatomy to constrain half k‐space MR image acquisition and reconstruction, in “Proc., SMR, 2nd Meeting
    • (1994) , pp. 60
    • Cao, Y.1    Levin, D.N.2
  • 27
    • 84981623951 scopus 로고    scopus 로고
    • Selection of observations in signal reconstruction. IEEE Trans. Signal Processing, in press.
    • Reeves, S.J.1    Heck, L.P.2
  • 29
  • 30
    • 84999274070 scopus 로고
    • Acquisition of the Karhunen‐Loeve expansion to reduce MR imaging times, in “Proc., IEEE Internat. Conf. on Image Proc., IEEE Computer Society Press, Los Alamitos, CA
    • (1994) , pp. 35
    • Weaver, J.B.1    Healy, D.M.2
  • 33
    • 84981649022 scopus 로고    scopus 로고
    • An efficient method for dynamic magnetic resonance imaging. IEEE Trans. Med. Imaging, in press.
    • Liang, Z.P.1    Lauterbur, P.C.2
  • 35
    • 84999142198 scopus 로고
    • Reconstructing magnetic resonance spectroscopic images using spatial domain priors, in “Proc., IEEE Internat. Conf. on Image Proc., IEEE Computer Society Press, Los Alamitos, CA
    • (1994) , pp. 6
    • Stokely, E.M.1    Twieg, D.B.2
  • 36
    • 84999143780 scopus 로고
    • Alternative k‐space sampling distributions for MR spectroscopic imaging, in “Proc., IEEE Internat. Conf. on Image Proc., IEEE Computer Society Press, Los Alamitos, CA
    • (1994) , pp. 11
    • Plevritis, S.K.1    Macovski, A.2
  • 37
    • 84981621210 scopus 로고
    • 2D locally focused MRI: application to proton spectroscopic imaging and to dynamic interventional and functional imaging, in “Proc., SMR, 3rd Annual Meeting, Nice, France
    • (1995)
    • Yao, L.1    Cao, Y.2    Levin, D.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.