메뉴 건너뛰기




Volumn 1, Issue 6, 1994, Pages 1039-1046

Surface recovery of silicone rubber used for HV outdoor insulation

Author keywords

[No Author keywords available]

Indexed keywords

AGING OF MATERIALS; DIFFUSION; ELECTRIC INSULATORS; HIGH TEMPERATURE OPERATIONS; MOLECULAR WEIGHT; PROTECTIVE COATINGS; SCANNING ELECTRON MICROSCOPY; SYNTHETIC RUBBER; TEMPERATURE; VULCANIZATION; X RAY ANALYSIS;

EID: 0028754486     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/94.368659     Document Type: Article
Times cited : (113)

References (15)
  • 1
    • 0025505982 scopus 로고
    • Composite Rod Insulators For ac Power Lines: Electrical Performance at a Coastal Testing Station
    • R. G. Houlgate and D. A. Swift, “Composite Rod Insulators For ac Power Lines: Electrical Performance at a Coastal Testing Station”, IEEE Trans. Power Delivery, Vol. 5, No. 4, pp. 1944–1955, 1990.
    • (1990) IEEE Trans. Power Delivery , vol.5 , Issue.4 , pp. 1944-1955
    • Houlgate, R.G.1    Swift, D.A.2
  • 2
    • 0026140347 scopus 로고
    • Surface Structural Changes of Naturally Aged Silicone and EPDM Composite Insulators
    • A. E. Vlastos and S. M. Gubanski, “Surface Structural Changes of Naturally Aged Silicone and EPDM Composite Insulators”, IEEE Trans. Power Delivery, Vol. 6, No. 2, pp. 888–900, 1991.
    • (1991) IEEE Trans. Power Delivery , vol.6 , Issue.2 , pp. 888-900
    • Vlastos, A.E.1    Gubanski, S.M.2
  • 3
    • 0027147316 scopus 로고
    • Accelerated Aging and Flashover Tests on 138 kV Non-ceramic Line Post Insulators
    • H. M. Schneider, W. W. Guidi, J. T. Burnham, R. S. Gorur and J. F. Hall, “Accelerated Aging and Flashover Tests on 138 kV Non-ceramic Line Post Insulators”, IEEE Trans. Power Delivery, Vol. 8, No. 1, pp. 325–336, 1993.
    • (1993) IEEE Trans. Power Delivery , vol.8 , Issue.1 , pp. 325-336
    • Schneider, H.M.1    Guidi, W.W.2    Burnham, J.T.3    Gorur, R.S.4    Hall, J.F.5
  • 4
    • 0024045638 scopus 로고
    • The Electrical Performance of Polymeric Insulating Materials Under Accelerated Aging in a Fog Chamber
    • R. S. Gorur, E. A. Cherney, R. Hackam and T. Orbeck, “The Electrical Performance of Polymeric Insulating Materials Under Accelerated Aging in a Fog Chamber”, IEEE Trans. Power Delivery, Vol. 3, No. 3, pp. 1157–1164, 1988.
    • (1988) IEEE Trans. Power Delivery , vol.3 , Issue.3 , pp. 1157-1164
    • Gorur, R.S.1    Cherney, E.A.2    Hackam, R.3    Orbeck, T.4
  • 5
    • 0026238254 scopus 로고
    • Contamination Performance of Silicone Rubber Cable Terminations
    • R. S. Gorur, L. A. Johnson and H. Hervig, “Contamination Performance of Silicone Rubber Cable Terminations”, IEEE Trans. Power Delivery, Vol. 6, No. 4, pp. 1366–1373, 1991.
    • (1991) IEEE Trans. Power Delivery , vol.6 , Issue.4 , pp. 1366-1373
    • Gorur, R.S.1    Johnson, L.A.2    Hervig, H.3
  • 8
    • 0025503108 scopus 로고
    • Surface Hydrophobicity of Polymeric Materials used for Outdoor Insulation
    • R. S. Gorur, J. Chang and O. G. Amburgey, “Surface Hydrophobicity of Polymeric Materials used for Outdoor Insulation”, IEEE Trans. Power Delivery, Vol. 5, No. 4, pp. 1923–1933, 1990.
    • (1990) IEEE Trans. Power Delivery , vol.5 , Issue.4 , pp. 1923-1933
    • Gorur, R.S.1    Chang, J.2    Amburgey, O.G.3
  • 9
    • 84941857973 scopus 로고    scopus 로고
    • Ac Clean Fog Tests on Non-ceramic Insulating Materials and a Comparison with Porcelain
    • Paper No. 94 WM 048-9 PWRD
    • A. De La O, R. S. Gorur and J. Chang, “Ac Clean Fog Tests on Non-ceramic Insulating Materials and a Comparison with Porcelain”, IEEE Trans. on Power Delivery, Paper No. 94 WM 048–9 PWRD.
    • IEEE Trans. on Power Delivery
    • De La O, A.1    Gorur, R.S.2    Chang, J.3
  • 11
    • 74949121431 scopus 로고
    • Transmission Line Reference Book
    • 345 kV and Above, Chapter 10
    • Transmission Line Reference Book, 345 kV and Above, Electric Power Research Institute El-2500, Chapter 10, 1985
    • (1985) Electric Power Research Institute El-2500