-
1
-
-
0039254760
-
A quadrature coil for the adult human head
-
V. J. Sank, C. N. Chen, and D. I. Hoult, “A quadrature coil for the adult human head,” J. Magn. Reson., vol. 69, 236-242, 1986.
-
(1986)
J. Magn. Reson.
, vol.69
, pp. 236-242
-
-
Sank, V.J.1
Chen, C.N.2
Hoult, D.I.3
-
2
-
-
3342905261
-
Analysis of MRI antenna inside an RF shield
-
Feb., (in Japanese)
-
H. Ochi, E. Yamamoto, K. Sawaya, and S. Adachi, “Analysis of MRI antenna inside an RF shield,” Trans. IEICE, vol. J76-B-II, no. 2, pp. 79-85, Feb. 1993 (in Japanese).
-
(1993)
Trans. IEICE
, vol.J76-B-II
, Issue.2
, pp. 79-85
-
-
Ochi, H.1
Yamamoto, E.2
Sawaya, K.3
Adachi, S.4
-
3
-
-
84984062042
-
Analysis of MRI antenna loaded by a man model
-
Apr., (in Japanese)
-
H. Ochi, E. Yamamoto, K. Sawaya, and S. Adachi, “Analysis of MRI antenna loaded by a man model,” Trans. IEICE, vol. J76-B-II, no. 4, pp. 253-259, Apr. 1993 (in Japanese).
-
(1993)
Trans. IEICE
, vol.J76-B-II
, Issue.4
, pp. 253-259
-
-
-
4
-
-
34547758853
-
An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers
-
D. W. Alderman and D. M. Grant, “An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers,”J. Magn. Reson., vol. 34, pp. 425-33, 1979.
-
(1979)
J. Magn. Reson.
, vol.34
, pp. 425-433
-
-
Alderman, D.W.1
Grant, D.M.2
-
5
-
-
0021923902
-
The slotted cylinder: An efficient probe for NMR imaging
-
L. W. Anne, L. Darrasse, J. Taquin, and M. Sauzade, “The slotted cylinder: An efficient probe for NMR imaging,” Magn. Reson. Med., vol. 2, pp. 20-28, 1985.
-
(1985)
Magn. Reson. Med.
, vol.2
, pp. 20-28
-
-
Anne, L.W.1
Darrasse, L.2
Taquin, J.3
Sauzade, M.4
-
6
-
-
0023221996
-
Whole body slotted tube resonator for proton NMR imaging at 2.0 Tesla
-
D. H. Hong, S. W. Lee, J. W. Ra, and Z. H. Cho, “Whole body slotted tube resonator for proton NMR imaging at 2.0 Tesla,” Magn. Reson. Imag., vol. 5 no. 3, pp. 239-243, 1987.
-
(1987)
Magn. Reson. Imag.
, vol.5
, Issue.3
, pp. 239-243
-
-
Hong, D.H.1
Lee, S.W.2
Ra, J.W.3
Cho, Z.H.4
-
7
-
-
38249021781
-
A cylindrical-window NMR probe with extended tuning range for studies of the developing heart
-
Mar.
-
G. J. Kost, S. E. Anderson, G. B. Matson, and C. B. Conboy, “A cylindrical-window NMR probe with extended tuning range for studies of the developing heart,” J. Magn. Reson., vol. 82, no. 1, pp. 238-252, Mar. 1989.
-
(1989)
J. Magn. Reson.
, vol.82
, Issue.1
, pp. 238-252
-
-
Kost, G.J.1
Anderson, S.E.2
Matson, G.B.3
Conboy, C.B.4
-
8
-
-
0025934166
-
An analytical model for the design of RF resonators for MR body imaging
-
T. K. Foo, C. E. Hayes, and Y. W. Kang, “An analytical model for the design of RF resonators for MR body imaging,” Magn. Reson. Med., vol. 21, pp. 165-177, 1991.
-
(1991)
Magn. Reson. Med.
, vol.21
, pp. 165-177
-
-
Foo, T.K.1
Hayes, C.E.2
Kang, Y.W.3
-
9
-
-
0025046949
-
Slotted resonator: Principles and applications for high-frequency imaging and spectroscopy on electrically conducting sample
-
E. J. Nijhof, “Slotted resonator: Principles and applications for high-frequency imaging and spectroscopy on electrically conducting sample,” Magn. Reson. Imag., vol. 8, no. 3, pp. 345-349, 1990.
-
(1990)
Magn. Reson. Imag.
, vol.8
, Issue.3
, pp. 345-349
-
-
Nijhof, E.J.1
-
10
-
-
12444305843
-
Analysis of slotted tube resonator for MRI
-
Aug., (in Japanese)
-
Q. Chen, K. Sawaya, S. Adachi, H. Ochi, and E. Yamamoto, “Analysis of slotted tube resonator for MRI,” Trans. IEICE, vol. J75-B-II, no. 8, pp. 602-605, Aug. 1992 (in Japanese).
-
(1992)
Trans. IEICE
, vol.J75-B-II
, Issue.8
, pp. 602-605
-
-
Chen, Q.1
Sawaya, K.2
Adachi, S.3
Ochi, H.4
Yamamoto, E.5
-
11
-
-
0027599601
-
Analysis of MRI slotted tube resonator having a shield of conducting circular cylinder
-
May
-
Q. Chen, K. Sawaya, S. Adachi, H. Ochi, and E. Yamamoto, “Analysis of MRI slotted tube resonator having a shield of conducting circular cylinder,” IEICE Trans. Commun., vol. E76-B, no. 5, pp. 553-560, May 1993.
-
(1993)
IEICE Trans. Commun.
, vol.E76-B
, Issue.5
, pp. 553-560
-
-
-
12
-
-
46549092488
-
An efficient, highly homogeneous radiofrequency coil for whole-bodly NMR imaging at 1.5 T
-
July
-
C. E. Haves, W. A. Edelstein, J. F. Schenck, O. M. Mueller, and M. Eash, “An efficient, highly homogeneous radiofrequency coil for whole-bodly NMR imaging at 1.5 T,” J. Magn. Reson., vol. 63, no. 3, pp. 622-628, July 1985.
-
(1985)
J. Magn. Reson.
, vol.63
, Issue.3
, pp. 622-628
-
-
Haves, C.E.1
Edelstein, W.A.2
Schenck, J.F.3
Mueller, O.M.4
Eash, M.5
-
16
-
-
84949076990
-
Study on magnetic resonance imaging antennas
-
Faculty of Engineering, Tohoku University, Japan
-
Q. Chen, “Study on magnetic resonance imaging antennas,” Ph.D. dissertation, Faculty of Engineering, Tohoku University, Japan, 1994.
-
(1994)
Ph.D. dissertation
-
-
Chen, Q.1
|