-
1
-
-
84956047429
-
Proceedings of the workshop on fluoroscopy: Strategies for improvements in performance, radiation safety and control
-
Center for Devices and Radiological Health, Food and Drug Administration, Roskville, MD
-
T. B. Shope, “Proceedings of the workshop on fluoroscopy: Strategies for improvements in performance, radiation safety and control,” Center for Devices and Radiological Health, Food and Drug Administration, Roskville, MD (1993).
-
(1993)
-
-
Shope, T.B.1
-
2
-
-
0028085296
-
Perceptual comparison of pulsed and continuous fluoroscopy
-
R. Aufrichtig, P. Xue, C. W. Thomas, G. C. Gilmore, and D. L. Wilson, “Perceptual comparison of pulsed and continuous fluoroscopy,” Med. Phys. 21, 245–256 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 245-256
-
-
Aufrichtig, R.1
Xue, P.2
Thomas, C.W.3
Gilmore, G.C.4
Wilson, D.L.5
-
3
-
-
0026982101
-
Comparison of detectability in pulsed versus continuous fluoroscopy: A simulation study
-
edited by Y. Kim (Bellingham, Washington
-
R. Aufrichtig, C. W. Thomas, G. C. Gilmore, and D. L. Wilson, “Comparison of detectability in pulsed versus continuous fluoroscopy: A simulation study,” in Proceedings of SPIE Medical Imaging VI, edited by Y. Kim (Bellingham, Washington, 1992), Vol. 1653, pp. 374–378.
-
(1992)
Proceedings of SPIE Medical Imaging VI
, vol.1653
, pp. 374-378
-
-
Aufrichtig, R.1
Thomas, C.W.2
Gilmore, G.C.3
Wilson, D.L.4
-
4
-
-
84953681643
-
Extension of the ideal observer model to pulsed fluoroscopic imaging
-
R. Aufrichtig, C. W. Thomas, G. C. Gilmore, and D. L. Wilson, “Extension of the ideal observer model to pulsed fluoroscopic imaging,” Radiology 185, 305 (1992).
-
(1992)
Radiology 185
, vol.305
-
-
Aufrichtig, R.1
Thomas, C.W.2
Gilmore, G.C.3
Wilson, D.L.4
-
5
-
-
0025846712
-
Observer performance in dynamic displays: Effect of frame rate on visual signal detection in noisy images
-
edited by B. E. Rogowitz, M. H. Brill, and J. P. Allebach (Bellingham, Washington
-
J. Whiting, D. Honig, E. Carterette, and N. Eigler, “Observer performance in dynamic displays: Effect of frame rate on visual signal detection in noisy images,” in Proceedings of SPIE Human Vision, Visual Processing, and Digital Display II, edited by B. E. Rogowitz, M. H. Brill, and J. P. Allebach (Bellingham, Washington, 1991), Vol. 1453, 165–176.
-
(1991)
Proceedings of SPIE Human Vision, Visual Processing, and Digital Display II
, vol.1453
, pp. 165-176
-
-
Whiting, J.1
Honig, D.2
Carterette, E.3
Eigler, N.4
-
6
-
-
0003474751
-
-
(Cambridge University, New York
-
W. H. Press, B. P. Flannery, S. A. Teukolsky, and W. T. Vetterling, Numerical Recipes in C: The Art of Scientific Computing (Cambridge University, New York, 1988).
-
(1988)
Numerical Recipes in C: The Art of Scientific Computing
-
-
Press, W.H.1
Flannery, B.P.2
Teukolsky, S.A.3
Vetterling, W.T.4
-
7
-
-
0022372857
-
Investigation of basic imaging properties in digital radiography. 6. mtfs of ii-tv digital imaging systems
-
H. Fujita, K. Doi, and M. L. Giger, “Investigation of basic imaging properties in digital radiography. 6. mtfs of ii-tv digital imaging systems,” Med. Phys. 12, 713–719 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 713-719
-
-
Fujita, H.1
Doi, K.2
Giger, M.L.3
-
8
-
-
0004116672
-
-
(Cambridge University, New York
-
D. J. Finney, Probit Analysis (Cambridge University, New York, 1971).
-
(1971)
Probit Analysis
-
-
Finney, D.J.1
-
9
-
-
0021286118
-
Retinal inhomogeneity. I. Spatiotemporal contrast sensitivity
-
D. H. Kelly, “Retinal inhomogeneity. I. Spatiotemporal contrast sensitivity,” J. Opt. Soc. Am. 1, 107–113 (1984).
-
(1984)
J. Opt. Soc. Am. 1
, pp. 107-113
-
-
Kelly, D.H.1
-
10
-
-
0019059705
-
Spatiotemporal characteristics of visual mechanisms: excitatory-inhibitory model
-
C. A. Burbeck and D. H. Kelly, “Spatiotemporal characteristics of visual mechanisms: excitatory-inhibitory model,” J. Opt. Soc. Am. 70, 1121 — 1126 (1980).
-
(1980)
J. Opt. Soc. Am. 70
, pp. 1121-1126
-
-
Burbeck, C.A.1
Kelly, D.H.2
-
11
-
-
84956047430
-
A model for perception of pulsed fluoroscopy image sequences
-
in press
-
R. Aufrichtig, C. Thomas, P. Xue, and D. L. Wilson, “A model for perception of pulsed fluoroscopy image sequences,” J. Opt. Soc. Am. A (in press).
-
J. Opt. Soc. Am.
, vol.A
-
-
Aufrichtig, R.1
Thomas, C.2
Xue, P.3
Wilson, D.L.4
-
12
-
-
0003073143
-
The perception of brightness and darkness: Relations to neuronal receptive fields
-
edited by L. Spillmann and J. S. Werner (Academic, San Diego, CA
-
A. Fiorentini, G. Baumgartner, S. Magnussen, P. H. Schiller, and J. P. Thomas, “The perception of brightness and darkness: Relations to neuronal receptive fields,” in Visual Perception: The Neurophysiological Foundations, edited by L. Spillmann and J. S. Werner (Academic, San Diego, CA, 1990), pp. 129–161.
-
(1990)
Visual Perception: The Neurophysiological Foundations
, pp. 129-161
-
-
Fiorentini, A.1
Baumgartner, G.2
Magnussen, S.3
Schiller, P.H.4
Thomas, J.P.5
-
14
-
-
77049258424
-
Optical and photoelectrical analog of the eye
-
S. O. H. Schade, “Optical and photoelectrical analog of the eye,” J. Opt. Soc. Am. 46, 721–739 (1956).
-
(1956)
J. Opt. Soc. Am.
, vol.46
, pp. 721-739
-
-
Schade, S.O.H.1
-
16
-
-
84956037497
-
Image stacking in x-ray angiography
-
Master’s thesis, Department of Biomedical Engineering, Case Western Reserve University
-
M. Sahin, “Image stacking in x-ray angiography,” Master’s thesis, Department of Biomedical Engineering, Case Western Reserve University (1993).
-
(1993)
-
-
Sahin, M.1
-
18
-
-
0004015222
-
Imaging Systems for Medical Diagnostics
-
edited by E. Krestel (Siemens AG, Berlin
-
Imaging Systems for Medical Diagnostics, edited by E. Krestel (Siemens AG, Berlin, 1991).
-
(1991)
-
-
-
19
-
-
0027810598
-
Enhancement of x-ray fluoroscopy images
-
Bellingham, Washington
-
A. Singh, D. L. Wilson, and R. Aufrichtig, “Enhancement of x-ray fluoroscopy images,” in Proceedings of SPIE Medical Imaging VII (Bellingham, Washington, 1993).
-
(1993)
Proceedings of SPIE Medical Imaging VII
-
-
Singh, A.1
Wilson, D.L.2
Aufrichtig, R.3
-
20
-
-
0027809533
-
Spatiotemporal x-ray fluoroscopy filtering using object detection
-
IEEE Computer Society, Washington, DC
-
R. Aufrichtig, D. Geiger, A. Singh, and D. L. Wilson, “Spatiotemporal x-ray fluoroscopy filtering using object detection,” in Computers in Cardiology (IEEE Computer Society, Washington, DC, 1993).
-
(1993)
Computers in Cardiology
-
-
Aufrichtig, R.1
Geiger, D.2
Singh, A.3
Wilson, D.L.4
-
21
-
-
84956047432
-
X-ray fluoroscopy Spatiotemporal filtering with object detection
-
submitted.
-
R. Aufrichtig and D. L. Wilson, “X-ray fluoroscopy Spatiotemporal filtering with object detection,” submitted.
-
-
-
Aufrichtig, R.1
Wilson, D.L.2
-
23
-
-
0025626195
-
The analysis of morphological filters with multiple structuring elements
-
J. Song and E. J. Delp, “The analysis of morphological filters with multiple structuring elements,” Comput. Vis. Graph. Image Process. 50, 308–328 (1990).
-
(1990)
Comput. Vis. Graph. Image Process.
, vol.50
, pp. 308-328
-
-
Song, J.1
Delp, E.J.2
-
24
-
-
0026622159
-
A study of the generalized morphological filter
-
J. Song and E. J. Delp, “A study of the generalized morphological filter,” Circuits Syst. Signal Process 11, 229–252 (1992).
-
(1992)
Circuits Syst. Signal Process
, vol.11
, pp. 229-252
-
-
Song, J.1
Delp, E.J.2
|