메뉴 건너뛰기




Volumn 21, Issue 12, 1994, Pages 1875-1883

Perception of fluoroscopy last-image hold

Author keywords

last image hold; visual perception; x ray dose; x ray fluoroscopy

Indexed keywords

CYLINDERS (SHAPES); FLUORESCENT SCREENS; PIXELS;

EID: 0028605949     PISSN: 00942405     EISSN: NA     Source Type: Journal    
DOI: 10.1118/1.597225     Document Type: Article
Times cited : (35)

References (24)
  • 1
    • 84956047429 scopus 로고
    • Proceedings of the workshop on fluoroscopy: Strategies for improvements in performance, radiation safety and control
    • Center for Devices and Radiological Health, Food and Drug Administration, Roskville, MD
    • T. B. Shope, “Proceedings of the workshop on fluoroscopy: Strategies for improvements in performance, radiation safety and control,” Center for Devices and Radiological Health, Food and Drug Administration, Roskville, MD (1993).
    • (1993)
    • Shope, T.B.1
  • 2
  • 3
    • 0026982101 scopus 로고
    • Comparison of detectability in pulsed versus continuous fluoroscopy: A simulation study
    • edited by Y. Kim (Bellingham, Washington
    • R. Aufrichtig, C. W. Thomas, G. C. Gilmore, and D. L. Wilson, “Comparison of detectability in pulsed versus continuous fluoroscopy: A simulation study,” in Proceedings of SPIE Medical Imaging VI, edited by Y. Kim (Bellingham, Washington, 1992), Vol. 1653, pp. 374–378.
    • (1992) Proceedings of SPIE Medical Imaging VI , vol.1653 , pp. 374-378
    • Aufrichtig, R.1    Thomas, C.W.2    Gilmore, G.C.3    Wilson, D.L.4
  • 4
    • 84953681643 scopus 로고
    • Extension of the ideal observer model to pulsed fluoroscopic imaging
    • R. Aufrichtig, C. W. Thomas, G. C. Gilmore, and D. L. Wilson, “Extension of the ideal observer model to pulsed fluoroscopic imaging,” Radiology 185, 305 (1992).
    • (1992) Radiology 185 , vol.305
    • Aufrichtig, R.1    Thomas, C.W.2    Gilmore, G.C.3    Wilson, D.L.4
  • 5
    • 0025846712 scopus 로고
    • Observer performance in dynamic displays: Effect of frame rate on visual signal detection in noisy images
    • edited by B. E. Rogowitz, M. H. Brill, and J. P. Allebach (Bellingham, Washington
    • J. Whiting, D. Honig, E. Carterette, and N. Eigler, “Observer performance in dynamic displays: Effect of frame rate on visual signal detection in noisy images,” in Proceedings of SPIE Human Vision, Visual Processing, and Digital Display II, edited by B. E. Rogowitz, M. H. Brill, and J. P. Allebach (Bellingham, Washington, 1991), Vol. 1453, 165–176.
    • (1991) Proceedings of SPIE Human Vision, Visual Processing, and Digital Display II , vol.1453 , pp. 165-176
    • Whiting, J.1    Honig, D.2    Carterette, E.3    Eigler, N.4
  • 7
    • 0022372857 scopus 로고
    • Investigation of basic imaging properties in digital radiography. 6. mtfs of ii-tv digital imaging systems
    • H. Fujita, K. Doi, and M. L. Giger, “Investigation of basic imaging properties in digital radiography. 6. mtfs of ii-tv digital imaging systems,” Med. Phys. 12, 713–719 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 713-719
    • Fujita, H.1    Doi, K.2    Giger, M.L.3
  • 8
    • 0004116672 scopus 로고
    • (Cambridge University, New York
    • D. J. Finney, Probit Analysis (Cambridge University, New York, 1971).
    • (1971) Probit Analysis
    • Finney, D.J.1
  • 9
    • 0021286118 scopus 로고
    • Retinal inhomogeneity. I. Spatiotemporal contrast sensitivity
    • D. H. Kelly, “Retinal inhomogeneity. I. Spatiotemporal contrast sensitivity,” J. Opt. Soc. Am. 1, 107–113 (1984).
    • (1984) J. Opt. Soc. Am. 1 , pp. 107-113
    • Kelly, D.H.1
  • 10
    • 0019059705 scopus 로고
    • Spatiotemporal characteristics of visual mechanisms: excitatory-inhibitory model
    • C. A. Burbeck and D. H. Kelly, “Spatiotemporal characteristics of visual mechanisms: excitatory-inhibitory model,” J. Opt. Soc. Am. 70, 1121 — 1126 (1980).
    • (1980) J. Opt. Soc. Am. 70 , pp. 1121-1126
    • Burbeck, C.A.1    Kelly, D.H.2
  • 11
    • 84956047430 scopus 로고    scopus 로고
    • A model for perception of pulsed fluoroscopy image sequences
    • in press
    • R. Aufrichtig, C. Thomas, P. Xue, and D. L. Wilson, “A model for perception of pulsed fluoroscopy image sequences,” J. Opt. Soc. Am. A (in press).
    • J. Opt. Soc. Am. , vol.A
    • Aufrichtig, R.1    Thomas, C.2    Xue, P.3    Wilson, D.L.4
  • 12
    • 0003073143 scopus 로고
    • The perception of brightness and darkness: Relations to neuronal receptive fields
    • edited by L. Spillmann and J. S. Werner (Academic, San Diego, CA
    • A. Fiorentini, G. Baumgartner, S. Magnussen, P. H. Schiller, and J. P. Thomas, “The perception of brightness and darkness: Relations to neuronal receptive fields,” in Visual Perception: The Neurophysiological Foundations, edited by L. Spillmann and J. S. Werner (Academic, San Diego, CA, 1990), pp. 129–161.
    • (1990) Visual Perception: The Neurophysiological Foundations , pp. 129-161
    • Fiorentini, A.1    Baumgartner, G.2    Magnussen, S.3    Schiller, P.H.4    Thomas, J.P.5
  • 14
    • 77049258424 scopus 로고
    • Optical and photoelectrical analog of the eye
    • S. O. H. Schade, “Optical and photoelectrical analog of the eye,” J. Opt. Soc. Am. 46, 721–739 (1956).
    • (1956) J. Opt. Soc. Am. , vol.46 , pp. 721-739
    • Schade, S.O.H.1
  • 16
    • 84956037497 scopus 로고
    • Image stacking in x-ray angiography
    • Master’s thesis, Department of Biomedical Engineering, Case Western Reserve University
    • M. Sahin, “Image stacking in x-ray angiography,” Master’s thesis, Department of Biomedical Engineering, Case Western Reserve University (1993).
    • (1993)
    • Sahin, M.1
  • 18
    • 0004015222 scopus 로고
    • Imaging Systems for Medical Diagnostics
    • edited by E. Krestel (Siemens AG, Berlin
    • Imaging Systems for Medical Diagnostics, edited by E. Krestel (Siemens AG, Berlin, 1991).
    • (1991)
  • 20
    • 0027809533 scopus 로고
    • Spatiotemporal x-ray fluoroscopy filtering using object detection
    • IEEE Computer Society, Washington, DC
    • R. Aufrichtig, D. Geiger, A. Singh, and D. L. Wilson, “Spatiotemporal x-ray fluoroscopy filtering using object detection,” in Computers in Cardiology (IEEE Computer Society, Washington, DC, 1993).
    • (1993) Computers in Cardiology
    • Aufrichtig, R.1    Geiger, D.2    Singh, A.3    Wilson, D.L.4
  • 21
    • 84956047432 scopus 로고    scopus 로고
    • X-ray fluoroscopy Spatiotemporal filtering with object detection
    • submitted.
    • R. Aufrichtig and D. L. Wilson, “X-ray fluoroscopy Spatiotemporal filtering with object detection,” submitted.
    • Aufrichtig, R.1    Wilson, D.L.2
  • 23
    • 0025626195 scopus 로고
    • The analysis of morphological filters with multiple structuring elements
    • J. Song and E. J. Delp, “The analysis of morphological filters with multiple structuring elements,” Comput. Vis. Graph. Image Process. 50, 308–328 (1990).
    • (1990) Comput. Vis. Graph. Image Process. , vol.50 , pp. 308-328
    • Song, J.1    Delp, E.J.2
  • 24
    • 0026622159 scopus 로고
    • A study of the generalized morphological filter
    • J. Song and E. J. Delp, “A study of the generalized morphological filter,” Circuits Syst. Signal Process 11, 229–252 (1992).
    • (1992) Circuits Syst. Signal Process , vol.11 , pp. 229-252
    • Song, J.1    Delp, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.