메뉴 건너뛰기




Volumn 41, Issue 5, 1994, Pages 480-487

Multiway Sequential Hypothesis Testing for Tachyarrhythmia Discrimination

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BIOMEDICAL ENGINEERING; ELECTROCARDIOGRAPHY;

EID: 0028436940     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/10.293223     Document Type: Article
Times cited : (38)

References (24)
  • 1
    • 0021645228 scopus 로고
    • From Holter monitors to automatic defibrillators; developments in ambulatory arrhythmia monitoring
    • N. V. Thakor, “From Holter monitors to automatic defibrillators; developments in ambulatory arrhythmia monitoring,” IEEE Trans. Biomed. Eng., vol. BME-31, pp. 700–708, 1984.
    • (1984) IEEE Trans. Biomed. Eng. , vol.BME-31 , pp. 700-708
    • Thakor, N.V.1
  • 2
    • 84939049781 scopus 로고
    • Computers in electrocardiography
    • Webster JG, Ed, N,Y,: Wiley
    • N. V. Thakor, “Computers in electrocardiography,” Enchyclopedia of Biomedical Instrumentation, Webster JG, Ed, N,Y,: Wiley, pp. 1040–1059, 1988.
    • (1988) Enchyclopedia of Biomedical Instrumentation , pp. 1040-1059
    • Thakor, N.V.1
  • 3
    • 0021286216 scopus 로고
    • Time domain and spectral analysis of electrograms in man during regular ventricular activity and ventricular fibrillation
    • L. Mörkrid, O. J. Ohm and H. Engedal, “Time domain and spectral analysis of electrograms in man during regular ventricular activity and ventricular fibrillation,” IEEE Trans. Biomed. Eng., vol. BME-31, pp. 350–355, 1984.
    • (1984) IEEE Trans. Biomed. Eng. , vol.BME-31 , pp. 350-355
    • Mörkrid, L.1    Ohm, O.J.2    Engedal, H.3
  • 4
    • 0025441983 scopus 로고
    • Tachycardia Recognition Algorithms for Implantable Systems
    • D. S. Khoury and B. L. Wilkoff, “Tachycardia Recognition Algorithms for Implantable Systems,” IEEE Eng. Med. Biology Mag., vol. 9, pp. 40–42. 1990.
    • (1990) IEEE Eng. Med. Biology Mag. , vol.9 , pp. 40-42
    • Khoury, D.S.1    Wilkoff, B.L.2
  • 5
    • 0025963089 scopus 로고
    • A time-domain analysis of intracardiac electrograms for arrhythmia detection
    • L. A. DiCarlo, R. D. Throne and J. M. Jenkins, “A time-domain analysis of intracardiac electrograms for arrhythmia detection,” PACE. Pacing Clin. Electrophysiol., vol. 14, pp. 329–336, 1991.
    • (1991) PACE. Pacing Clin. Electrophysiol. , vol.14 , pp. 329-336
    • DiCarlo, L.A.1    Throne, R.D.2    Jenkins, J.M.3
  • 6
    • 0016949567 scopus 로고
    • Considerations in the development of automatic implantable defibrillator
    • A. Langer, M. S. Heilman, M. M. Mower and M. Mirowski, “Considerations in the development of automatic implantable defibrillator,” Med. lustrum., vol. 10, pp. 163–167, 1976.
    • (1976) Med. lustrum. , vol.10 , pp. 163-167
    • Langer, A.1    Heilman, M.S.2    Mower, M.M.3    Mirowski, M.4
  • 7
    • 0025395831 scopus 로고
    • Tachycardia and Fibrillation Detection by Automatic Implantable Cardioverter-Defibrillators: Sequential Testing in the Time Domain
    • N. V. Thakor and K. Pan, “Tachycardia and Fibrillation Detection by Automatic Implantable Cardioverter-Defibrillators: Sequential Testing in the Time Domain,” IEEE Eng. Med. Biology Mag., pp. 21–24, 1990.
    • (1990) IEEE Eng. Med. Biology Mag. , pp. 21-24
    • Thakor, N.V.1    Pan, K.2
  • 8
    • 0023347751 scopus 로고
    • Ventricular fibrillation detection by regression test of autocorrelation function
    • C. Shoupu, N. V. Thakor and M. M. Mower, “Ventricular fibrillation detection by regression test of autocorrelation function,” Med. Biol. Eng. Comput., vol. 25. pp. 241–249, 1987.
    • (1987) Med. Biol. Eng. Comput. , vol.25 , pp. 241-249
    • Shoupu, C.1    Thakor, N.V.2    Mower, M.M.3
  • 9
    • 0023009583 scopus 로고
    • Measurement of differences in timing and sequence between two ventricular electrodes as a means of tachycardia differentiation
    • A. D. Mercando and S. Furman, “Measurement of differences in timing and sequence between two ventricular electrodes as a means of tachycardia differentiation,” PACE. Pacing Clin. Electrophysiol., vol. 9. pp. 1069–1078, 1986.
    • (1986) PACE. Pacing Clin. Electrophysiol. , vol.9 , pp. 1069-1078
    • Mercando, A.D.1    Furman, S.2
  • 10
    • 0025002168 scopus 로고
    • The Bin Area Method: a computationally efficient technique for analysis of ventricular and atrial intracardiac electrograms
    • R. D. Throne, J. M. Jenkins and L. A. DiCario, “The Bin Area Method: a computationally efficient technique for analysis of ventricular and atrial intracardiac electrograms,” PACE. Pacing Clin. Electrophysiol., vol. 13, pp. 1286–1297, 1990.
    • (1990) PACE. Pacing Clin. Electrophysiol. , vol.13 , pp. 1286-1297
    • Throne, R.D.1    Jenkins, J.M.2    DiCario, L.A.3
  • 12
    • 0001662608 scopus 로고
    • Recognition of ventricular fibrillation utilizing the power spectrum of the ECG
    • M. Nygards and J. Hulting, “Recognition of ventricular fibrillation utilizing the power spectrum of the ECG,” Comput. Cardiol., pp. 393–397, 1977.
    • (1977) Comput. Cardiol. , pp. 393-397
    • Nygards, M.1    Hulting, J.2
  • 13
    • 0024399942 scopus 로고
    • The coherence spectrum, A quantitative discriminator of fibrillatory and nonfibrillatory cardiac rhythms
    • K. M. Ropella, A. V. Sahakian, J. M. Baerman and S. Swiryn, “The coherence spectrum, A quantitative discriminator of fibrillatory and nonfibrillatory cardiac rhythms,” Circulation, vol. 80, pp. 112–119, 1989.
    • (1989) Circulation , vol.80 , pp. 112-119
    • Ropella, K.M.1    Sahakian, A.V.2    Baerman, J.M.3    Swiryn, S.4
  • 14
    • 0023886369 scopus 로고
    • Diagnosis of atrial fibrillation using electrograms from chronic leads: evaluation of computer algorithms
    • J. Jenkins, K. H. Noh, A. Guezennec, T. Bump and R. Arzbaecher, “Diagnosis of atrial fibrillation using electrograms from chronic leads: evaluation of computer algorithms,” PACE. Pacing din. Electrophysiol., vol. 11, pp. 622–631, 1988.
    • (1988) PACE. Pacing din. Electrophysiol. , vol.11 , pp. 622-631
    • Jenkins, J.1    Noh, K.H.2    Guezennec, A.3    Bump, T.4    Arzbaecher, R.5
  • 15
    • 0021742054 scopus 로고
    • Tachycardia detection in implantable antitachycardia devices
    • J. Jenkins, T. Bump and F. Mukenbeck, “Tachycardia detection in implantable antitachycardia devices,” PACE. Pacing Clin. Electrophysiol., vol. 7, pp. 1273–1277, 1984.
    • (1984) PACE. Pacing Clin. Electrophysiol. , vol.7 , pp. 1273-1277
    • Jenkins, J.1    Bump, T.2    Mukenbeck, F.3
  • 16
    • 0024474893 scopus 로고
    • Evaluation of techniques for recognition of ventricular arrhythmias by implanted devices
    • K. L. Ripley, T. E. Bump and R. C. Arzbaecher, “Evaluation of techniques for recognition of ventricular arrhythmias by implanted devices,” IEEE Trans. Biomed. Eng., vol. 36, pp. 618–624, 1989.
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 618-624
    • Ripley, K.L.1    Bump, T.E.2    Arzbaecher, R.C.3
  • 17
    • 0025483745 scopus 로고
    • Ventricular tachycardia and fibrillation detection by a sequential hypothesis testing algorithm
    • N. V. Thakor, Y. S. Zhu and K. Y Pan, “Ventricular tachycardia and fibrillation detection by a sequential hypothesis testing algorithm,” IEEE Trans. Biomed. Eng., vol. 37, pp. 837–843, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 837-843
    • Thakor, N.V.1    Zhu, Y.S.2    Pan, K.Y.3
  • 18
    • 0023277488 scopus 로고
    • Automatic implantable cardioverter defibrillator: patient survival, battery longevity and shock delivery analysis
    • M. D. Gabry, R. Brofman, D. Johnston, R. Frame, S. G. Kim, L. E. Waspe, J. D. Fisher and S. Furman, “Automatic implantable cardioverter defibrillator: patient survival, battery longevity and shock delivery analysis,” J. Am. Coll. Cardiol., vol. 8, pp. 1349–1356, 1987.
    • (1987) J. Am. Coll. Cardiol. , vol.8 , pp. 1349-1356
    • Gabry, M.D.1    Brofman, R.2    Johnston, D.3    Frame, R.4    Kim, S.G.5    Waspe, L.E.6    Fisher, J.D.7    Furman, S.8
  • 19
    • 0026100615 scopus 로고
    • Clinical performance of the implantable cardioverter defibrillator: electrocardiographic documentation of 101 spontaneous discharges
    • J. Maloney. M. Masterson. D. Khoury, R. Trohman, B. Wilkoff, T. Simmons. V. Morant and L. Castle, “Clinical performance of the implantable cardioverter defibrillator: electrocardiographic documentation of 101 spontaneous discharges,” PACE. vol. 14, pp. 280–285. 1991.
    • (1991) PACE , vol.14 , pp. 280-285
    • Maloney, J.1    Masterson, M.2    Khoury, D.3    Trohman, R.4    Wilkoff, B.5    Simmons, T.6    Morant, V.7    Castle, L.8
  • 20
    • 0027238588 scopus 로고
    • Implantable cardioverter-defibrillator therapy in the absence of significant symptoms: rhythm diagnosis and management aided by stored electrogram analysis
    • B. G. Hook, D. J. Callans, R. B. Keliman, B. T. Flores and F. E. Marchlinski, “Implantable cardioverter-defibrillator therapy in the absence of significant symptoms: rhythm diagnosis and management aided by stored electrogram analysis,” Circulation, vol. 87. pp. 1897–1906, 1993.
    • (1993) Circulation , vol.87 , pp. 1897-1906
    • Hook, B.G.1    Callans, D.J.2    Keliman, R.B.3    Flores, B.T.4    Marchlinski, F.E.5
  • 21
    • 0003503387 scopus 로고
    • Sequential Analysis
    • N.Y.: Wiley & Sons
    • A. Wald, “Sequential Analysis,” N.Y.: Wiley & Sons, pp. 212, 1947.
    • (1947) , pp. 212
    • Wald, A.1
  • 22
    • 0018996660 scopus 로고
    • A sequential multiple hypothesis test for the unknown parameters of a Gaussian distribution
    • S. Fleischer and E. Shwedyk, “A sequential multiple hypothesis test for the unknown parameters of a Gaussian distribution,” IEEE Trans. Binmecl. Eng., vol. BME-26, pp. 255-259. 1980.
    • (1980) IEEE Trans. Binmecl. Eng. , vol.BME-26 , pp. 255-259
    • Fleischer, S.1    Shwedyk, E.2
  • 23
    • 0021892137 scopus 로고
    • A real-time QRS detection algorithm
    • J. Pan and W. J. Tompkins, “A real-time QRS detection algorithm,” IEEE Trans. Binmed. Eng., vol. BME-32. pp. 230-236, 1985.
    • (1985) IEEE Trans. Binmed. Eng. , vol.BME-32 , pp. 230-236
    • Pan, J.1    Tompkins, W.J.2
  • 24
    • 0026203883 scopus 로고
    • Applications of Adaptive Filtering to ECG Analysis: Noise Cancellation and Arrhythmia Detection
    • N. V. Thakor and Y. Zhu. “Applications of Adaptive Filtering to ECG Analysis: Noise Cancellation and Arrhythmia Detection.” IEEE Trans. Biomed. Eng., vol. 38, pp. 785-794, 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 785-794
    • Thakor, N.V.1    Zhu, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.