메뉴 건너뛰기




Volumn 41, Issue 1, 1994, Pages 123-129

Reciprocity Calibration of Ultrasonic Contact Transducers

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; CYLINDERS (SHAPES); FORECASTING; MATHEMATICAL MODELS; MEDICAL APPLICATIONS; SIGNAL RECEIVERS; SPHERES; TRANSMITTERS; ULTRASONIC DIFFRACTION; ULTRASONIC MEASUREMENT;

EID: 0028344440     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.265829     Document Type: Article
Times cited : (3)

References (17)
  • 1
    • 84953658467 scopus 로고
    • Self-reciprocity calibration of electroacoustic transducers
    • E. L. Carstensen, “Self-reciprocity calibration of electroacoustic transducers,” J. Acoust. Soc. Amer., vol. 55, pp. 961–965, 1947.
    • (1947) J. Acoust. Soc. Amer. , vol.55 , pp. 961-965
    • Carstensen, E.L.1
  • 4
    • 0001508636 scopus 로고
    • General reciprocity parameters
    • R. C. Heyser, “General reciprocity parameters,” J. Audio. Eng. Soc., vol. 15, pp. 370-382, 1967.
    • (1967) J. Audio. Eng. Soc. , vol.15 , pp. 370-382
    • Heyser, R.C.1
  • 5
    • 0023982833 scopus 로고
    • Calibration of hydrophones based on reciprocity and time delay spectrometry
    • G. Ludwig and K. Brendel, “Calibration of hydrophones based on reciprocity and time delay spectrometry,” IEEE Trans. Ultrason., Ferroelec., Freq. Contr., vol. 35, pp. 168–174, 1988.
    • (1988) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.35 , pp. 168-174
    • Ludwig, G.1    Brendel, K.2
  • 8
    • 0024717397 scopus 로고
    • Determination of the sensitivity of ultrasonic contact transducers
    • B. Fay, G. Ludwig, and H. P. Reimann, “Determination of the sensitivity of ultrasonic contact transducers,” Acustica, vol. 69, pp. 73–80, 1989.
    • (1989) Acustica , vol.69 , pp. 73-80
    • Fay, B.1    Ludwig, G.2    Reimann, H.P.3
  • 9
    • 0000087838 scopus 로고
    • Diffraction effects in the ultrasonic field of a piston source and their importance in the accurate measurement of attenuation
    • H. Seki, A. Granato, and R. Truell, “Diffraction effects in the ultrasonic field of a piston source and their importance in the accurate measurement of attenuation,” J. Acoust. Soc. Amer., vol. 28, pp. 230-238, 1956.
    • (1956) J. Acoust. Soc. Amer. , vol.28 , pp. 230-238
    • Seki, H.1    Granato, A.2    Truell, R.3
  • 10
    • 0015414456 scopus 로고
    • Numerical calculation of the diffraction corrections for the precise measurement of ultrasound absorption
    • A. S. Khimunin, “Numerical calculation of the diffraction corrections for the precise measurement of ultrasound absorption,” Acoustica, vol. 27, pp. 173–181, 1972
    • (1972) Acoustica , vol.27
    • Khimunin, A.S.1
  • 11
    • 0016050819 scopus 로고
    • An exact expression for the Lommel diffraction correction integral
    • P. H. Rogers and A. L. Van Buren. “An exact expression for the Lommel diffraction correction integral,” J. Acoust. Soc. Amer., vol. 55, pp. 724-728, 1974.
    • (1974) J. Acoust. Soc. Amer. , vol.55 , pp. 724-728
    • Rogers, P.H.1    Van Buren, A.L.2
  • 12
    • 0017019817 scopus 로고
    • Numerische Berechnung der Beugungsverluste im Schallfeld von Ultraschallwandlern
    • B. Fay, “Numerische Berechnung der Beugungsverluste im Schallfeld von Ultraschallwandlern,” Acustica, vol. 36, pp. 209–213, 1976.
    • (1976) Acustica , vol.36 , pp. 209-213
    • Fay, B.1
  • 13
    • 0019637095 scopus 로고
    • Exact integral expression for the diffraction loss of a circular piston source
    • K. Beissner, “Exact integral expression for the diffraction loss of a circular piston source,” Acustica, vol. 49, pp. 212–217, 1981.
    • (1981) Acustica , vol.49 , pp. 212-217
    • Beissner, K.1
  • 14
    • 84938169050 scopus 로고
    • Calibration of ultrasonic contact transducers
    • B. Fay and G. Ludwig, “Calibration of ultrasonic contact transducers,” in Proc. Ultrason. Int., 1989, pp. 146–151.
    • (1989) Proc. Ultrason. Int. , pp. 146-151
    • Fay, B.1    Ludwig, G.2
  • 16
    • 3242818630 scopus 로고
    • Kalibrierung kreisförmiger Ultraschallköpfe: Beugungsverluste des kreisförmigen Schwingers bei hnpulsechomessungen am Halbzylinder und an der Halbkugel
    • B. Fay, “Kalibrierung kreisförmiger Ultraschallköpfe: Beugungsverluste des kreisförmigen Schwingers bei hnpulsechomessungen am Halbzylinder und an der Halbkugel,” Materialprüfung, vol. 34, pp. 193–196, 1992.
    • (1992) Materialprüfung , vol.34 , pp. 193-196
    • Fay, B.1
  • 17
    • 84938164596 scopus 로고
    • Diffraction loss in ultrasonic measurements on half cylinders and half spheres
    • B. Fay and H. P. Reimann, “Diffraction loss in ultrasonic measurements on half cylinders and half spheres,” in Proc. Ultrason. Int., 1991, pp. 407–410.
    • (1991) Proc. Ultrason. Int. , vol.1991 , pp. 407-410
    • Fay, B.1    Reimann, H.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.