메뉴 건너뛰기




Volumn 3, Issue , 1994, Pages S73-S81

Evaluating and optimizing test strategies in automated perimetry

Author keywords

Optimization; Perimetry; Test Strategies; Thresholds

Indexed keywords

COMPUTER ASSISTED PERIMETRY; COMPUTER SIMULATION; CONFERENCE PAPER; GLAUCOMA; HUMAN; PRIORITY JOURNAL; SCREENING; VISION TEST; VISUAL FIELD; VISUAL THRESHOLD;

EID: 0028342936     PISSN: 10570829     EISSN: 1536481X     Source Type: Journal    
DOI: 10.1097/00061198-199400321-00010     Document Type: Article
Times cited : (10)

References (26)
  • 3
    • 3142599953 scopus 로고
    • The competer
    • Drance SM, Anderson DR, eds., Orlando, FL: Grune & Stratton
    • Heijl A. The competer. In: Drance SM, Anderson DR, eds. Automatic perimetry in glaucoma. A practical guide. Orlando, FL: Grune & Stratton, 1985:113-21.
    • (1985) Automatic perimetry in glaucoma. A practical guide , pp. 113-121
    • Heijl, A.1
  • 4
    • 84934801716 scopus 로고
    • Quantitative perimetry. Dicon
    • Drance SM, Anderson DR, eds., Orlando, FL: Grune & Stratton
    • Mills RP. Quantitative perimetry. Dicon. In: Drance SM, Anderson DR, eds. Automatic perimetry in glaucoma. A practical guide. Orlando, FL: Grune & Stratton, 1985:99-112.
    • (1985) Automatic perimetry in glaucoma. A practical guide , pp. 99-112
    • Mills, R.P.1
  • 5
    • 0017519514 scopus 로고
    • Time changes of contrast thresholds during automatic perimetry
    • Heijl A. Time changes of contrast thresholds during automatic perimetry. Acta Ophthalmol 1977;55:696-708.
    • (1977) Acta Ophthalmol , vol.55 , pp. 696-708
    • Heijl, A.1
  • 6
    • 0020601188 scopus 로고
    • Changes in differential thresholds in patients with glaucoma during prolonged perimetry
    • Heijl A, Drance SM. Changes in differential thresholds in patients with glaucoma during prolonged perimetry. Br J Ophthalmol 1983;67:512-16.
    • (1983) Br J Ophthalmol , vol.67 , pp. 512-516
    • Heijl, A.1    Drance, S.M.2
  • 7
    • 0018092581 scopus 로고
    • Mathematical optimization of glaucoma field screening protocols
    • Rabin S, Kolesar P. Mathematical optimization of glaucoma field screening protocols. Doc Ophthalmol 1978;45:361-80.
    • (1978) Doc Ophthalmol , vol.45 , pp. 361-380
    • Rabin, S.1    Kolesar, P.2
  • 9
    • 84937095365 scopus 로고
    • A new approach to glaucoma visual field screening
    • Krakau CET. A new approach to glaucoma visual field screening. Invest Ophthalmol Vis Sci 1990;31(Suppl):16.
    • (1990) Invest Ophthalmol Vis Sci , vol.31 , pp. 16
    • Krakau, C.E.T.1
  • 11
    • 0024220080 scopus 로고
    • Screening for glaucomatous visual field defects. The relationship between sensitivity, specificity and the number of test locations
    • Henson DB, Chauhan BC, Hobley A. Screening for glaucomatous visual field defects. The relationship between sensitivity, specificity and the number of test locations. Ophthalmic Physiol Opt 1988;8:123-7.
    • (1988) Ophthalmic Physiol Opt , vol.8 , pp. 123-127
    • Henson, D.B.1    Chauhan, B.C.2    Hobley, A.3
  • 17
    • 0000736895 scopus 로고
    • Improved threshold estimates using full staircase data
    • Mills RP, Heijl A, eds., Amsterdam: Kugler
    • Olsson J, Åsman P, Rootzén H, Heijl A. Improved threshold estimates using full staircase data. In: Mills RP, Heijl A, eds. Perimetry update 1990/91. Amsterdam: Kugler, 1990:245-9.
    • (1990) Perimetry update 1990/91 , pp. 245-249
    • Olsson, J.1    Åsman, P.2    Rootzén, H.3    Heijl, A.4
  • 18
    • 0343522058 scopus 로고
    • A rapid heuristic test procedure for automated perimetry
    • Mills RP, Heijl A, eds., Amsterdam: Kugler
    • Johnson CA, Shapiro LR. A rapid heuristic test procedure for automated perimetry. In: Mills RP, Heijl A, eds. Perimetry update 1990/91. Amsterdam: Kugler, 1990:245-9.
    • (1990) Perimetry update 1990/91 , pp. 245-249
    • Johnson, C.A.1    Shapiro, L.R.2
  • 19
    • 84936074562 scopus 로고
    • Properties of staircases in automated perimetry
    • Johnson CA. Properties of staircases in automated perimetry. Invest Ophthalmol Vis Sci 1985;26(suppl):217.
    • (1985) Invest Ophthalmol Vis Sci , vol.26 , pp. 217
    • Johnson, C.A.1
  • 20
    • 0026715019 scopus 로고
    • Properties of staircase procedures for estimating thresholds in automated perimetry
    • Johnson CA, Chauhan BC, Shapiro LR. Properties of staircase procedures for estimating thresholds in automated perimetry. Invest Ophthalmol Vis Sci 1992;33:2966-74.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2966-2974
    • Johnson, C.A.1    Chauhan, B.C.2    Shapiro, L.R.3
  • 21
    • 0028289814 scopus 로고
    • Estimating thresholds in conventional and high-pass resolution perimetry using computer simulation
    • Chauhan BC, House PH. Estimating thresholds in conventional and high-pass resolution perimetry using computer simulation. J Glaucoma 1994;3:132-9.
    • (1994) J Glaucoma , vol.3 , pp. 132-139
    • Chauhan, B.C.1    House, P.H.2
  • 22
    • 0027716210 scopus 로고
    • Characteristics of frequency-of-seeing curves in normals, glaucoma suspects and glaucoma patients
    • Chauhan BC, Tompkins JD, LeBlanc RP, McCormick TA. Characteristics of frequency-of-seeing curves in normals, glaucoma suspects and glaucoma patients. Invest Ophthalmol Vis Sci 1993;34:3534-40.
    • (1993) Invest Ophthalmol Vis Sci , vol.34 , pp. 3534-3540
    • Chauhan, B.C.1    Tompkins, J.D.2    LeBlanc, R.P.3    McCormick, T.A.4
  • 23
    • 0001799624 scopus 로고
    • KRAKEN: A computer simulation procedure for static, kinetic, suprathreshold and heuristic perimetry
    • Heijl A, ed., Berkeley: Kugler & Khedini
    • Shapiro LR, Johnson CA, Kennedy RL. KRAKEN: A computer simulation procedure for static, kinetic, suprathreshold and heuristic perimetry. In: Heijl A, ed. Perimetry update 1988/89. Berkeley: Kugler & Khedini, 1989:431-8.
    • (1989) Perimetry update 1988/89 , pp. 431-438
    • Shapiro, L.R.1    Johnson, C.A.2    Kennedy, R.L.3
  • 24
    • 0021280712 scopus 로고
    • Differential light threshold in automated static perimetry. Factors influencing short-term fluctuation
    • Flammer J, Drance SM, Fankhauser F, Augustiny L. Differential light threshold in automated static perimetry. Factors influencing short-term fluctuation. Arch Ophthalmol 1984;102:876-9.
    • (1984) Arch Ophthalmol , vol.102 , pp. 876-879
    • Flammer, J.1    Drance, S.M.2    Fankhauser, F.3    Augustiny, L.4
  • 25
    • 0026717105 scopus 로고
    • Glaucoma Hemifield test. Automated visual field evaluation
    • Åsman P, Heijl A. Glaucoma Hemifield test. Automated visual field evaluation. Arch Ophthalmol 1992;110:812-19.
    • (1992) Arch Ophthalmol , vol.110 , pp. 812-819
    • Åsman, P.1    Heijl, A.2
  • 26
    • 0000139368 scopus 로고
    • A package for the statistical analysis of visual fields
    • Heijl A, Lindgren G, Olsson J. A package for the statistical analysis of visual fields. Doc Ophthalmol 1987;49:153-68.
    • (1987) Doc Ophthalmol , vol.49 , pp. 153-168
    • Heijl, A.1    Lindgren, G.2    Olsson, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.