메뉴 건너뛰기




Volumn 25, Issue 1, 1994, Pages 4-10

Blinded-Reader comparison of magnetic resonance angiography and duplex ultrasonography for carotid artery bifurcation stenosis

Author keywords

Carotid artery diseases; Diagnostic imaging; Ultrasonics

Indexed keywords

ADULT; AGED; ARTERIOGRAPHY; ARTICLE; CAROTID ARTERY BIFURCATION; CAROTID ARTERY OBSTRUCTION; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; ECHOGRAPHY; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; PREDICTION; PRIORITY JOURNAL; SCREENING TEST; ULTRASOUND;

EID: 0028107712     PISSN: 00392499     EISSN: 15244628     Source Type: Journal    
DOI: 10.1161/01.STR.25.1.4     Document Type: Article
Times cited : (138)

References (37)
  • 1
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis
    • North American Symptomatic Carotid Endarterectomy Trial Collaborators. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med. 1991;325:445-453.
    • (1991) N Engl J Med , vol.325 , pp. 445-453
  • 2
    • 0025869608 scopus 로고
    • MRC European Carotid Surgery Trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis
    • European Carotid Surgery Trial Collaborists’ Group. MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. Lancet. 1991;337:1235-1243.
    • (1991) Lancet , vol.337 , pp. 1235-1243
  • 3
    • 0019824735 scopus 로고
    • Noninvasive screening of extracranial carotid disease: Duplex sonography with angiographic correlation
    • Clark WP, Hatten HP. Noninvasive screening of extracranial carotid disease: duplex sonography with angiographic correlation. AJNR. 1981;2:443-447.
    • (1981) AJNR , vol.2 , pp. 443-447
    • Clark, W.P.1    Hatten, H.P.2
  • 4
    • 0001369879 scopus 로고
    • Ultrasonic duplex scanning of extracranial carotid arteries: Improved accuracy using new features from the common carotid artery
    • Roederer GO, Langlois YE, Chan AW, et al. Ultrasonic duplex scanning of extracranial carotid arteries: improved accuracy using new features from the common carotid artery. J Cardiovasc Ultrasonogr. 1982;1:373-380.
    • (1982) J Cardiovasc Ultrasonogr , vol.1 , pp. 373-380
    • Roederer, G.O.1    Langlois, Y.E.2    Chan, A.W.3
  • 5
    • 0020037978 scopus 로고
    • Evaluation of the peak frequency ratio (PFR) measurement in the detection of internal carotid artery stenosis
    • Keagy BA, Pharr WF, Thomas D, Bowles DE. Evaluation of the peak frequency ratio (PFR) measurement in the detection of internal carotid artery stenosis. J Cardiovasc Ultrasongr. 1982;10:109-112.
    • (1982) J Cardiovasc Ultrasongr , vol.10 , pp. 109-112
    • Keagy, B.A.1    Pharr, W.F.2    Thomas, D.3    Bowles, D.E.4
  • 6
    • 0020576010 scopus 로고
    • Correlations of high resolution B-mode and continuous wave Doppler sonography with arteriography in diagnosis of stenosis
    • Zweibel WJ, Austin CW, Sackett FJ, Strother C, Mistretta C. Correlations of high resolution B-mode and continuous wave Doppler sonography with arteriography in diagnosis of stenosis. Radiology. 1983;149:523-532.
    • (1983) Radiology , vol.149 , pp. 523-532
    • Zweibel, W.J.1    Austin, C.W.2    Sackett, F.J.3    Strother, C.4    Mistretta, C.5
  • 7
    • 0020751787 scopus 로고
    • Comparison of ultrasound scanning/Doppler with digital subtraction angiography in evaluating carotid arterial disease
    • Bendick PJ, Jackson WP, Becker GJ. Comparison of ultrasound scanning/Doppler with digital subtraction angiography in evaluating carotid arterial disease. Med Instrum. 1983;3:220-222.
    • (1983) Med Instrum , vol.3 , pp. 220-222
    • Bendick, P.J.1    Jackson, W.P.2    Becker, G.J.3
  • 8
    • 0020615373 scopus 로고
    • Duplex ultrasound scanning of the carotid arteries with velocity spectrum analysis
    • Garth KE, Carroll BA, Sommer FG, Oppenheimer DA. Duplex ultrasound scanning of the carotid arteries with velocity spectrum analysis. Radiology. 1983;147:823-827.
    • (1983) Radiology , vol.147 , pp. 823-827
    • Garth, K.E.1    Carroll, B.A.2    Sommer, F.G.3    Oppenheimer, D.A.4
  • 10
    • 0022643131 scopus 로고
    • Carotid artery disease: New criteria for evaluation by sonographic duplex scanning
    • Vaisman U, Wojciechowski M. Carotid artery disease: new criteria for evaluation by sonographic duplex scanning. Radiology. 1986;158:253-255.
    • (1986) Radiology , vol.158 , pp. 253-255
    • Vaisman, U.1    Wojciechowski, M.2
  • 11
    • 0024306287 scopus 로고
    • Internal carotid artery stenosis: Accuracy and reproducibility of color-Doppler-assisted duplex imaging
    • Polak JF, Dobkin GR, O’Leary DH, Wang A-M, Cutler SS. Internal carotid artery stenosis: accuracy and reproducibility of color-Doppler-assisted duplex imaging. Radiology. 1989;173:793-798.
    • (1989) Radiology , vol.173 , pp. 793-798
    • Polak, J.F.1    Dobkin, G.R.2    O’Leary, D.H.3    Wang, A.-M.4    Cutler, S.S.5
  • 12
    • 0023840489 scopus 로고
    • The limitations of diagnosis of carotid occlusion by Doppler ultrasound
    • Bornstein NM, Beleov ZG, Norris JW. The limitations of diagnosis of carotid occlusion by Doppler ultrasound. Ann Surg. 1988; 315-317.
    • (1988) Ann Surg , pp. 315-317
    • Bornstein, N.M.1    Beleov, Z.G.2    Norris, J.W.3
  • 13
    • 0026601814 scopus 로고
    • Detection of internal carotid artery stenosis: Comparison of MR angiography, color Doppler, sonography, and arteriography
    • Polak JF, Bajakian RL, O’Leary DH, Anderson MR, Donaldson MC, Jolesz FA. Detection of internal carotid artery stenosis: comparison of MR angiography, color Doppler, sonography, and arteriography. Radiology. 1992;182:35-40.
    • (1992) Radiology , vol.182 , pp. 35-40
    • Polak, J.F.1    Bajakian, R.L.2    O’Leary, D.H.3    Anderson, M.R.4    Donaldson, M.C.5    Jolesz, F.A.6
  • 16
    • 0027505824 scopus 로고
    • Carotid artery: Prospective blinded comparison of twodimensional time-of-flight MR angiography with conventional angiography and duplex US
    • Huston J, Lewis BD, Wiebers DO, Meyer FB, Riederer SJ, Weaver AL. Carotid artery: prospective blinded comparison of twodimensional time-of-flight MR angiography with conventional angiography and duplex US. Radiology. 1993;186:339-344.
    • (1993) Radiology , vol.186 , pp. 339-344
    • Huston, J.1    Lewis, B.D.2    Wiebers, D.O.3    Meyer, F.B.4    Riederer, S.J.5    Weaver, A.L.6
  • 19
    • 0025809024 scopus 로고
    • 3DFT MR angiography of the carotid bifurcation: Potential and limitations as a screening examination
    • Masaryk AM, Ross JS, DiCello MC, Modic MT, Paranandi L, Masaryk TJ. 3DFT MR angiography of the carotid bifurcation: potential and limitations as a screening examination. Radiology. 1991:179-804.
    • (1991) Radiology , pp. 179-804
    • Masaryk, A.M.1    Ross, J.S.2    DiCello, M.C.3    Modic, M.T.4    Paranandi, L.5    Masaryk, T.J.6
  • 22
    • 0026008977 scopus 로고
    • North American Symptomatic Carotid Endarterectomy Trial: Methods, patient characteristics, and progress
    • North American Symptomatic Carotid Endarterectomy Trial Steering Committee. North American Symptomatic Carotid Endarterectomy Trial: methods, patient characteristics, and progress. Stroke. 1991;22:711-720.
    • (1991) Stroke , vol.22 , pp. 711-720
    • North American Symptomatic Carotid Endarterectomy Trial Steering Committee1
  • 23
    • 0027463917 scopus 로고
    • How to measure carotid stenosis
    • Fox AJ. How to measure carotid stenosis. Radiology. 1993;186:316-318.
    • (1993) Radiology , vol.186 , pp. 316-318
    • Fox, A.J.1
  • 24
    • 0027410697 scopus 로고
    • Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70-99% internal carotid artery stenosis with duplex scanning
    • Moneta GL, Edwards JM, Chitwood RW, Taylor LM Jr, Lee RW, Cummings CA, Porter JM. Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70-99% internal carotid artery stenosis with duplex scanning. J Vase Surg. 1993;17:152-159.
    • (1993) J Vase Surg , vol.17 , pp. 152-159
    • Moneta, G.L.1    Edwards, J.M.2    Chitwood, R.W.3    Taylor, L.M.4    Lee, R.W.5    Cummings, C.A.6    Porter, J.M.7
  • 25
    • 0024325998 scopus 로고
    • MR angiography with two-dimensional acquisition and three-dimensional display: Work in progress
    • Keller PJ, Drayer BP, Fram EK, Williams KD, Dumoulin CL, Souza SP. MR angiography with two-dimensional acquisition and three-dimensional display: work in progress. Radiology. 1989;173:527-532.
    • (1989) Radiology , vol.173 , pp. 527-532
    • Keller, P.J.1    Drayer, B.P.2    Fram, E.K.3    Williams, K.D.4    Dumoulin, C.L.5    Souza, S.P.6
  • 27
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 28
    • 0026007879 scopus 로고
    • Matchmaking and McNemar in the comparison of diagnostic modalities
    • Dwyer AJ. Matchmaking and McNemar in the comparison of diagnostic modalities. Radiology. 1991;178:328-330.
    • (1991) Radiology , vol.178 , pp. 328-330
    • Dwyer, A.J.1
  • 29
    • 0027391669 scopus 로고
    • Carotid endarterectomy: Preoperative evaluation of candidates with combined Doppler sonography and MR angiography
    • Polak JF, Kalina P, Donaldson MC, O’Leary DH, Whittemore AD, Mannick JA. Carotid endarterectomy: preoperative evaluation of candidates with combined Doppler sonography and MR angiography. Radiology. 1993;186:333-338.
    • (1993) Radiology , vol.186 , pp. 333-338
    • Polak, J.F.1    Kalina, P.2    Donaldson, M.C.3    O’Leary, D.H.4    Whittemore, A.D.5    Mannick, J.A.6
  • 30
    • 0026692894 scopus 로고
    • Magnetic resonance imaging of angiographically occult runoff vessels in peripheral arterial occlusive disease
    • Owen RS, Carpenter JP, Baum RA, Perloff LJ, Cope C. Magnetic resonance imaging of angiographically occult runoff vessels in peripheral arterial occlusive disease. N Engl J Med. 1992;326:1577-1581.
    • (1992) N Engl J Med , vol.326 , pp. 1577-1581
    • Owen, R.S.1    Carpenter, J.P.2    Baum, R.A.3    Perloff, L.J.4    Cope, C.5
  • 31
    • 0021320947 scopus 로고
    • Flow patterns in the human carotid artery bifurcation
    • Motomiya M, Karino T. Flow patterns in the human carotid artery bifurcation. Stroke. 1984;15:50-56.
    • (1984) Stroke , vol.15 , pp. 50-56
    • Motomiya, M.1    Karino, T.2
  • 34
    • 0025237141 scopus 로고
    • Carotid artery disease assessed by color flow imaging: Correlation with standard sonography and angiography
    • Steinke W, Kloetzsch C, Hennerici M. Carotid artery disease assessed by color flow imaging: correlation with standard sonography and angiography. AJNR. 1990;11:259-266.
    • (1990) AJNR , vol.11 , pp. 259-266
    • Steinke, W.1    Kloetzsch, C.2    Hennerici, M.3
  • 36
    • 0025070034 scopus 로고
    • Artifacts in maximum-intensity-projection display of MR angiograms
    • Anderson CM, Saloner D, Tsuruda JS, Shapeero LG, Lee RE. Artifacts in maximum-intensity-projection display of MR angiograms. AJR. 1990;154:623-629.
    • (1990) AJR , vol.154 , pp. 623-629
    • Anderson, C.M.1    Saloner, D.2    Tsuruda, J.S.3    Shapeero, L.G.4    Lee, R.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.