메뉴 건너뛰기




Volumn 9, Issue 5, 1994, Pages 503-510

High hip center in revision arthroplasty

Author keywords

acetabular defects; high hip center; revision arthroplasty

Indexed keywords

ACETABULUM; ARTICLE; AVASCULAR NECROSIS; CLINICAL ARTICLE; COXITIS; ENDOPROSTHESIS LOOSENING; FEMUR HEAD; FOLLOW UP; FUNCTIONAL ASSESSMENT; HIP DISEASE; HIP DYSPLASIA; HIP RADIOGRAPHY; HUMAN; LEG LENGTH INEQUALITY; MOBILIZATION; MUSCLE STRENGTH; OSTEOARTHRITIS; PAIN ASSESSMENT; POSTOPERATIVE PAIN; REOPERATION; RHEUMATOID ARTHRITIS; TOTAL HIP PROSTHESIS; WALKING AID;

EID: 0028042344     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/0883-5403(94)90097-3     Document Type: Article
Times cited : (106)

References (23)
  • 1
  • 4
    • 0023814304 scopus 로고
    • Coxarthrosis after congenital dysplasia: treatment by total hip arthroplasty without acetabular bone-grafting
    • (1988) J Bone Joint Surg , vol.70 A , pp. 1140
    • McQueary1    Johnston2
  • 11
    • 0025679359 scopus 로고
    • Failure of acetabular autogenous grafts in total hip arthroplasty. Increasing incidence: a follow-up note
    • (1990) J Bone Joint Surg , vol.71 A , pp. 1536
    • Mulroy1    Harris2
  • 14
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737
    • Harris1
  • 15
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • (1976) Clin Orthop , vol.121 , pp. 20
    • DeLee1    Charnley2
  • 18
    • 0026442786 scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation: radiographic analysis of eighty-three primary hip replacements at a minimum of five years
    • (1992) J Bone Joint Surg , vol.74 A , pp. 1130
    • Schmalzried1    Harris2
  • 20
    • 0023810920 scopus 로고
    • Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening.
    • (1988) Clin Orthop Relat Res , vol.235 , pp. 111
    • Gustilo1    Pasternak2
  • 21
    • 0023724638 scopus 로고
    • Revision of nonseptic, loose, cemented femoral components using modern cement techniques
    • (1988) J Arthroplasty , vol.3 , pp. 241
    • Rubash1    Harris2
  • 23
    • 0017622529 scopus 로고
    • Roentgenographic measurements after Muller total hip replacement: correlations among roentgenographic measurements and hip strength and mobility
    • (1977) J Bone Joint Surg , vol.59 A , pp. 948
    • Gore1    Murray2    Gardner3    Septic4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.