메뉴 건너뛰기




Volumn 17, Issue 7, 1994, Pages 1243-1255

Clinical Experience with a New Cardioverter Defibrillator Capable of Biphasic Waveform Pulse and Enhanced Data Storage: Results of a Prospective Multicenter Study

Author keywords

biphasic defibrillation waveform; implantable cardioverter defibrillator; nonthoracotomy systems; stored electrograms; sudden cardiac death

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CARDIOVERSION; CONGESTIVE CARDIOMYOPATHY; DEFIBRILLATION; DEFIBRILLATOR; FEMALE; HEART FIBRILLATION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; SUDDEN DEATH; SUPRAVENTRICULAR TACHYCARDIA;

EID: 0027978501     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1994.tb01491.x     Document Type: Article
Times cited : (35)

References (46)
  • 2
    • 0019479339 scopus 로고
    • Clinical treatment of life‐threatening ventricular tachyarrhythmias with the automatic implantable defibrillator
    • (1981) Am Heart J , vol.102 , pp. 265-270
    • Mirowski, M1    Reid, P2    Watkins, L3
  • 5
    • 0023876909 scopus 로고
    • The automatic implantable cardioverter/defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmias
    • (1988) J Am Coll Cardiol , vol.11 , pp. 1278-1286
    • Kelly, PA1    Cannom, DS2    Garan, H3
  • 10
    • 0027447773 scopus 로고
    • Patient survival comparison in three generations of automatic implantable cardioverter defibrillators; Review of 12 years, 25,000 patients
    • (1993) PACE , vol.16 , pp. 174-178
    • Nisam, S1    Mower, M2    Thomas, A3
  • 12
    • 0027450908 scopus 로고
    • the PCD Investigators Defibrillation thresholds and perioperative mortality associated with endocardial and epicardial lead systems
    • (1993) PACE , vol.16 , pp. 202-207
    • Saksena, S1
  • 17
    • 0024552857 scopus 로고
    • Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform
    • (1989) Am Heart J , vol.117 , pp. 122-127
    • Winkle, RA1    Mead, RH2    Ruder, MA3
  • 25
    • 0023552108 scopus 로고
    • Improved cardiac cell excitation with symmetrical biphasic defibrillator waveforms
    • (1987) Am J Physiol , vol.253 H , pp. 1418-1424
    • Jones, JL1    Jones, RE.2
  • 28
    • 0023786718 scopus 로고
    • Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator
    • (1988) Am J Cardiol , vol.62 , pp. 393-398
    • Marchlinski, FE1    Flores, B2    Miller, JM3
  • 29
    • 0026877545 scopus 로고
    • Defibrillation threshold: Clinical utility and therapeutic implications
    • (1991) PACE , vol.15 , pp. 932-949
    • Singer, I1    Lang, D.2
  • 31
    • 0021864688 scopus 로고
    • Comparative efficacy of transvenous cardioversion and pacing in patients with sustained ventricular tachycardia: A prospective, randomized crossover study
    • (1985) Circulation , vol.72 , pp. 153-160
    • Saksena, S1    Chandran, P2    Shah, Y.3
  • 35
    • 0026063738 scopus 로고
    • Sudden bradyarrhythmic death in patients with the impiantable cardioverter‐defibrillator: Report of two cases
    • (1991) PACE , vol.14 , pp. 395-398
    • Khastgir, R1    Aarons, D2    Veltri, E.3
  • 38
    • 0026100615 scopus 로고
    • Clinical performance of the implantable cardioverter defibrillator: Eloctrocardiographic documentation of 101 spontaneous discharges
    • (1991) PACE , vol.14 , pp. 280-285
    • Maloney, J1    Masterson, M2    Khoury, D.3
  • 39
    • 0025788298 scopus 로고
    • Accuracy of rhythm classification using a data log system in implantable cardioverter defibrillator
    • (1991) PACE , vol.14 , pp. 1911-1916
    • Wang, PJ1    Mandalakas, N2    Clyne, C3
  • 44
    • 0025720709 scopus 로고
    • Use of bipolar recordings from patch‐patch and rate sensing leads to distinguish ventricular tachycardia from supraventricular rhythms in patients with implantable cardioverter defibrillators
    • (1991) PACE , vol.14 , pp. 1917-1922
    • Callans, DJ1    Hook, BG2    Marchlinski, FE.3
  • 45
    • 0027321725 scopus 로고
    • Gespeicherte intrakardiale Elektrogramme: Genauigkeit der Arrhythmieklassifikation bei Patienten mit Kardioverter/Defibrillator‐System
    • (1993) Z Kardiol , vol.82 , pp. 459-465
    • Neuzner, J1    Pitschner, HF2    Konig, S3
  • 46


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.