메뉴 건너뛰기




Volumn 32, Issue 8, 1994, Pages 573-579

Augmentation of transfers for a quadriplegic patient using an implanted fns system. Case report

Author keywords

Fns; Functional neuromuscular stimulation; Functional restoration; Neuroprosthesis; Quadriplegia

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CLINICAL FEATURE; ELECTRODE; GLUTEUS MAXIMUS MUSCLE; HAMSTRING; HUMAN; IMPLANTATION; MALE; MUSCLE EXCITATION; MUSCLE STRENGTH; NEUROMUSCULAR FUNCTION; PRIORITY JOURNAL; QUADRICEPS FEMORIS MUSCLE; QUADRIPLEGIA; STANDING;

EID: 0027930568     PISSN: 00311758     EISSN: None     Source Type: Journal    
DOI: 10.1038/sc.1994.91     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0013570219 scopus 로고
    • Spinal Cord Injuries
    • Blackwell Scientific Publications, Oxford
    • Guttmann L (1973) Spinal Cord Injuries. Comprehensive Management and Research. Blackwell Scientific Publications, Oxford.
    • (1973) Comprehensive Management and Research
    • Guttmann, L.1
  • 3
    • 0027270934 scopus 로고
    • Report on a conference on motor prostheses for workplace mobility of paraplegic patients in North America
    • Kantor C, Andrews BJ, Marsolais EB et al (1993) Report on a conference on motor prostheses for workplace mobility of paraplegic patients in North America. Paraplegia 31: 439-456.
    • (1993) Paraplegia , vol.31 , pp. 439-456
    • Kantor, C.1    Rews, B.J.2    Marsolais, E.B.3
  • 4
    • 84970057405 scopus 로고
    • Ambulation with functional electrical stimulation (FES) in individuals with paraplegia and incomplete quadriplegia
    • Chaplin E, Habasevich R (1992) Ambulation with functional electrical stimulation (FES) in individuals with paraplegia and incomplete quadriplegia. Neurology 42 (Suppl 3): 638.
    • (1992) Neurology , vol.42 , pp. 638
    • Chaplin, E.1    Habasevich, R.2
  • 5
    • 0022690889 scopus 로고
    • A computer controlled walking system: The combination of an orthosis with functional electrical stimulation
    • Petrofsky JS, Phillips CA, Douglas R, Larson P (1986) A computer controlled walking system: The combination of an orthosis with functional electrical stimulation. J Clin Eng 11: 121-133.
    • (1986) J Clin Eng , vol.11 , pp. 121-133
    • Petrofsky, J.S.1    Phillips, C.A.2    Douglas, R.3    Larson, P.4
  • 7
    • 0023767445 scopus 로고
    • Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand
    • Keith MW, Peckham PH, Thrope GB et al (1988) Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand. Clin Orthop 233: 25-33.
    • (1988) Clin Orthop , vol.233 , pp. 25-33
    • Keith, M.W.1    Peckham, P.H.2    Thrope, G.B.3
  • 8
    • 0022749698 scopus 로고
    • Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities
    • Marsolais EB, Kobetic R (1986) Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities. J Rehabil Res De\’ 23: 1-8.
    • (1986) J Rehabil Res De , vol.23 , pp. 1-8
    • Marsolais, E.B.1    Kobetic, R.2
  • 9
    • 0028439538 scopus 로고
    • Design and clinical application of a double helix electrode for functional electrical stimulation
    • ScheinerPolando G, Marsolais EB (1994) Design and clinical application of a double helix electrode for functional electrical stimulation. IEEE Trans Biomed Eng 41.
    • (1994) IEEE Trans Biomed Eng , pp. 41
    • Scheinerpolando, G.1    Marsolais, E.B.2
  • 10
    • 0020071031 scopus 로고
    • Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered airflow system
    • Salvati EA, Robinson RP, Zeno SM et al (1982) Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered airflow system. J Bone Joint Surg Am 64: 525-535.
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 525-535
    • Salvati, E.A.1    Robinson, R.P.2    Zeno, S.M.3
  • 11
    • 0023378409 scopus 로고
    • An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle
    • Smith B., Peckham PH, Keith MW, Roscoe DD (1977) an externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle. IEEE Trans Biomed Eng 34: 499-508.
    • (1977) IEEE Trans Biomed Eng , vol.34 , pp. 499-508
    • Smith, B.1    Peckham, P.H.2    Keith, M.W.3    Roscoe, D.D.4
  • 13
    • 0028238424 scopus 로고
    • Endoscopic electrode implantation for enhanced stimulation of the hamstring branches of the sciatic nerve
    • Osman SG, Marsolais EB (1994) Endoscopic electrode implantation for enhanced stimulation of the hamstring branches of the sciatic nerve. Arthroscopy 10.
    • (1994) Arthroscopy , pp. 10
    • Osman, S.G.1    Marsolais, E.B.2
  • 14
    • 0027199261 scopus 로고
    • The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury observed benefits during gait studies
    • Granat MH, Ferguson ACB, Andrews BJ, Delargy M (1993) The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury observed benefits during gait studies. Paraplegia 31: 207-215.
    • (1993) Paraplegia , vol.31 , pp. 207-215
    • Granat, M.H.1    Ferguson, A.2    Rews, B.J.3    Delargy, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.