1
-
-
0018460728
-
Medical ultrasound imaging: An overview of principles and instrumentation
-
April
-
J. F. Havlice and J. C. Taenzer, “Medical ultrasound imaging: An overview of principles and instrumentation,” in Proc. IEEE, vol. 67, pp. 620-641, April 1979.
-
(1979)
Proc. IEEE.
, vol.67
, pp. 620-641
-
-
Havlice, J.F.1
Taenzer, J.C.2
-
2
-
-
0021464525
-
The influence of front-end hardware on digital ultrasonic imaging
-
July
-
M. E. Schafer and P. A. Lewin, “The influence of front-end hardware on digital ultrasonic imaging,” IEEE Trans. Sonics. Ultrason., vol. 31, pp. 295-306, July 1984.
-
(1984)
IEEE Trans. Sonics. Ultrason.
, vol.31
, pp. 295-306
-
-
Schafer, M.E.1
Lewin, P.A.2
-
3
-
-
0024076498
-
Applications of VLSI circuits to medical imaging
-
Sept.
-
M. O'Donnell, “Applications of VLSI circuits to medical imaging,” in Proc. IEEE, vol. 76, pp. 1106-1114, Sept. 1988.
-
(1988)
Proc. IEEE.
, vol.76
, pp. 1106-1114
-
-
O'Donnell, M.1
-
4
-
-
84941493033
-
Custom NMOS chip for medical ultrasound
-
May
-
J. P. Stonestorm and W. A. Anderson, “Custom NMOS chip for medical ultrasound,” VLSI Design, pp. 44-49, May 1982.
-
(1982)
VLSI Design.
, pp. 44-49
-
-
Stonestorm, J.P.1
Anderson, W.A.2
-
5
-
-
0025577221
-
Real-time phased-array imaging using digital beam forming and autonomous channel control
-
M. O'Donnell et al., “Real-time phased-array imaging using digital beam forming and autonomous channel control,” in Proc. 1990 IEEE Ultrason. Symp., pp. 1499-1502, 1990.
-
(1990)
Proc. 1990 IEEE Ultrason. Symp.
, pp. 1499-1502
-
-
O'Donnell, M.1
-
6
-
-
0024738302
-
Ultrasonic phased-array scanner with digital echo synthesis for Doppler echocardiography
-
Sept.
-
R. M. Lutolf, A. Vieli, and S. Basler, “Ultrasonic phased-array scanner with digital echo synthesis for Doppler echocardiography,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 36, pp. 494-506, Sept. 1989.
-
(1989)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.36
, pp. 494-506
-
-
Lutolf, R.M.1
Vieli, A.2
Basler, S.3
-
7
-
-
0026045104
-
Ultimate limits in ultrasonic image resolution
-
R. A. Harris et al., “Ultimate limits in ultrasonic image resolution,” Ultrasound in Med. and Biol., vol. 17, pp. 547-558, 1991.
-
(1991)
Ultrasound in Med. and Biol.
, vol.17
, pp. 547-558
-
-
Harris, R.A.1
-
8
-
-
0042084130
-
The design of special purpose VLSI chips
-
Jan.
-
M. J. Foster and H. T. Kung, “The design of special purpose VLSI chips,” IEEE Computer, pp. 26-40, Jan. 1980.
-
(1980)
IEEE Computer.
, pp. 26-40
-
-
Foster, M.J.1
Kung, H.T.2
-
9
-
-
0021466923
-
Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors
-
July
-
D. K. Peterson and G. S. Kino, “Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors,” IEEE Sonics. Ultrason., vol. 31, pp. 337-351, July 1984.
-
(1984)
IEEE Sonics. Ultrason.
, vol.31
, pp. 337-351
-
-
Peterson, D.K.1
Kino, G.S.2
-
10
-
-
0018479351
-
Digital interpolation beamforming for low-pass and bandpass signals
-
April
-
R. G. Pridham and R. A. Mucci, “Digital interpolation beamforming for low-pass and bandpass signals,” in Proc. IEEE, vol. 67, pp. 904-919, April 1979.
-
(1979)
Proc. IEEE.
, vol.67
, pp. 904-919
-
-
Pridham, R.G.1
Mucci, R.A.2
-
11
-
-
0020763686
-
FIR filter designed over a discrete powers-of-two coefficient space
-
June
-
Y. C. Lim and S. R. Parker, “FIR filter designed over a discrete powers-of-two coefficient space,” IEEE Trans. Acoust., Speech, Signal Processing,” vol. 31, pp. 583-590, June 1983.
-
(1983)
IEEE Trans. Acoust., Speech, Signal Processing
, vol.31
, pp. 583-590
-
-
Lim, Y.C.1
Parker, S.R.2
-
12
-
-
0025968669
-
In vivo measurements of ultrasonic beam distortion in the breast
-
G. E. Trahey, P. D. Freiburger, L. F. Nock, and D. C. Sullivan, “In vivo measurements of ultrasonic beam distortion in the breast,” Ultrasonic Imaging, vol. 13, pp. 71-90, 1991.
-
(1991)
Ultrasonic Imaging.
, vol.13
, pp. 71-90
-
-
Trahey, G.E.1
Freiburger, P.D.2
Nock, L.F.3
Sullivan, D.C.4
-
13
-
-
0020833422
-
A scan conversion algorithm for displaying ultrasound images
-
Oct.
-
S. Leavitt and B. F. Hunt and H. G. Larsen, “A scan conversion algorithm for displaying ultrasound images,” Hewlett-Packard J., vol. 34, pp. 30-34, Oct. 1983.
-
(1983)
Hewlett-Packard J.
, vol.34
, pp. 30-34
-
-
Leavitt, S.1
Hunt, B.F.2
Larsen, H.G.3
-
14
-
-
0020972539
-
Beam steering with linear arrays
-
Aug.
-
O. T. von Ramm and S. W. Smith, “Beam steering with linear arrays,” IEEE Trans. Biomed. Eng., vol. 30, pp. 438-452, Aug. 1983.
-
(1983)
IEEE Trans. Biomed. Eng.
, vol.30
, pp. 438-452
-
-
von Ramm, O.T.1
Smith, S.W.2
-
15
-
-
0024111013
-
Phase-aberration correction using signals from point reflectors and diffuse scatterers: Basic principles
-
Nov.
-
S. W. Flax and M. O'Donnell, “Phase-aberration correction using signals from point reflectors and diffuse scatterers: Basic principles,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 35, pp. 758-767, Nov. 1988.
-
(1988)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.35
, pp. 758-767
-
-
Flax, S.W.1
O'Donnell, M.2
-
16
-
-
0026128875
-
Comparisons of image quality factors for phase aberration correction with diffuse and point targets
-
Mar.
-
D. Zhao and G. E. Trahey, “Comparisons of image quality factors for phase aberration correction with diffuse and point targets,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 38, pp. 125-132, Mar. 1991.
-
(1991)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.38
, pp. 125-132
-
-
Zhao, D.1
Trahey, G.E.2
-
17
-
-
85043068731
-
Optimal focusing through aberrating media: A comparison between time reversal mirror and time delay correction techniques
-
F. Wu, et al., “Optimal focusing through aberrating media: A comparison between time reversal mirror and time delay correction techniques,” in Proc. 1991 IEEE Ultrason. Symp., pp. 1195-1199, 1991.
-
(1991)
Proc. 1991 IEEE Ultrason. Symp.
, pp. 1195-1199
-
-
Wu, F.1
-
18
-
-
84941869641
-
Adaptive digital beamforming for real-time phased array ultrasound imaging
-
M. Karaman, A. Atalar, and H. Koymen, “Adaptive digital beamforming for real-time phased array ultrasound imaging,” in Proc. 1991 IEEE Ultrason. Symp., pp. 1207-1210, 1991.
-
(1991)
Proc. 1991 IEEE Ultrason. Symp.
, pp. 1207-1210
-
-
Karaman, M.1
Atalar, A.2
Koymen, H.3
-
19
-
-
85013986690
-
An evaluation of transducer design and algorithm performance for two dimensional phase aberration correction
-
G. E. Trahey and P. D. Freiburger, “An evaluation of transducer design and algorithm performance for two dimensional phase aberration correction,” in Proc. 1991 IEEE Ultrason. Symp., pp. 1181-1187, 1991.
-
(1991)
Proc. 1991 IEEE Ultrason. Symp.
, pp. 1181-1187
-
-
Trahey, G.E.1
Freiburger, P.D.2
-
20
-
-
84965380336
-
Aberration correction on a two-dimensional anisotropic phased array
-
M. O'Donnell and P. C. Li, “Aberration correction on a two-dimensional anisotropic phased array,” in Proc. 1991 IEEE Ultrason. Symp., pp. 1189-1193, 1991.
-
(1991)
Proc. 1991 IEEE Ultrason. Symp.
, pp. 1189-1193
-
-
O'Donnell, M.1
Li, P.C.2
-
21
-
-
33747928790
-
An investigation of wavefront distortion correction: Correction using averaged phase information and the effect of correction one and two dimensions
-
R. Kanda, Y. Sumino, K. Takamizawa, and H. Sasaki, “An investigation of wavefront distortion correction: Correction using averaged phase information and the effect of correction one and two dimensions,” in Proc. 1991 IEEE Ultrason. Symp., pp. 1201-1206, 1991.
-
(1991)
Proc. 1991 IEEE Ultrason. Symp.
, pp. 1201-1206
-
-
Kanda, R.1
Sumino, Y.2
Takamizawa, K.3
Sasaki, H.4
-
22
-
-
0019581410
-
On the simulation of a class of time delay estimation algorithms
-
June
-
K. Scarbrough, N. Ahmed and G. C. Carter, “On the simulation of a class of time delay estimation algorithms,” IEEE Trans. Acoust. Speech, Signal Process., vol. 29, pp. 534-539, June 1981.
-
(1981)
IEEE Trans. Acoust. Speech, Signal Process.
, vol.29
, pp. 534-539
-
-
Scarbrough, K.1
Ahmed, N.2
Carter, G.C.3
-
23
-
-
0024112560
-
Phase-aberration correction using signals from point reflectors and diffuse scatterers: Experimental results
-
Nov.
-
M. O'Donnell and S. W. Flax, “Phase-aberration correction using signals from point reflectors and diffuse scatterers: Experimental results,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 35, pp. 768-774, Nov. 1988.
-
(1988)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.35
, pp. 768-774
-
-
O'Donnell, M.1
Flax, S.W.2
-
24
-
-
0025217716
-
A new digital phased array system for dynamic focusing and steering with reduced sampling rate
-
T. H. Song and S. B. Park, “A new digital phased array system for dynamic focusing and steering with reduced sampling rate,” Ultrasonic Imaging, vol. 12, pp. 1-16, 1990.
-
(1990)
Ultrasonic Imaging.
, vol.12
, pp. 1-16
-
-
Song, T.H.1
Park, S.B.2
-
25
-
-
84963515564
-
A VLSI receive beamformer for digital ultrasound imaging
-
M. Karaman, E. Kolağasioğlu, and A. Atalar, “A VLSI receive beamformer for digital ultrasound imaging,” in Proc. ICASSP '92, pp. V-657- 660, 1992.
-
(1992)
Proc. ICASSP '92
, pp. V-657-V-660
-
-
Karaman, M.1
Kolağasioğlu, E.2
Atalar, A.3
-
26
-
-
0022722967
-
Fault and error models for VLSI
-
May
-
J. A. Abraham and W. K. Fuchs, “Fault and error models for VLSI,” in Proc. IEEE, vol. 74, pp. 639-654, May 1986.
-
(1986)
Proc. IEEE.
, vol.74
, pp. 639-654
-
-
Abraham, J.A.1
Fuchs, W.K.2
-
27
-
-
0019923189
-
Why systolic architectures?
-
Jan.
-
H. T. Kung, “Why systolic architectures?” IEEE Computer, pp. 37-46, Jan. 1982.
-
(1982)
IEEE Computer
, pp. 37-46
-
-
Kung, H.T.1
|